The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Probing Cellular Chemistry in Biological Systems with Microelectrodes
Abstract
Over the past 20 years, the technological impediments to fabricating electrodes of micrometer dimensions have been largely overcome. These small electrodes can be readily applied to probe chemical events at the surface of tissues or individual biological cells; they can even be used to monitor concentration changes within intact animals. These measurements can be made on rapid time scales and with minimal perturbation of the system under study. Several recent applications have provided important insights into chemical processes at cells and in tissues. Examples include molecular flux measurements at the surface of single cells and through skin—which can offer insights into oxidative stress, exocytosis, and drug delivery—and real-time brain neurotransmitter monitoring in living rats, which reveals correlations between behavior and molecular events in the brain. Such findings can promote interdisciplinary collaborations and may lead to a broader understanding of the chemical aspects of biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Subsecond dopamine release promotes cocaine seeking
Phillips, P. E. M., Stuber, G. D., Heien, M. L. A. V., Wightman, R. M., & Carelli, R. M. (2003) · Nature · doi:10.1038/nature01476 · Cited by 1,113
Self-citationWightman, R. M., Jankowski, J. A., Kennedy, R. T., Kawagoe, K. T., Schroeder, T. J., Leszczyszyn, D. J., Near, J. A., Diliberto, E. J., & Viveros, O. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.23.10754 · Cited by 893
Self-citationReal-time measurement of dopamine fluctuations after cocaine in the brain of behaving rats
Heien, M. L. A. V., Khan, A. S., Ariansen, J. L., Cheer, J. F., Phillips, P. E. M., Wassum, K. M., & Wightman, R. M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0504657102 · Cited by 482
Self-citation
Cited by
Advanced Carbon Electrode Materials for Molecular Electrochemistry
McCreery, R. L. (2008) · Chemical Reviews · doi:10.1021/cr068076m · Cited by 2,729
Unique properties of mesoprefrontal neurons within a dual mesocorticolimbic dopamine system
Lammel, S., Hetzel, A., Häckel, O., Jones, I., Liss, B., & Roeper, J. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.022 · Cited by 976
Efficient water oxidation at carbon nanotube–polyoxometalate electrocatalytic interfaces
Toma, F. M., Sartorel, A., Iurlo, M., Carraro, M., Parisse, P., Maccato, C., Rapino, S., Gonzalez, B. R., Amenitsch, H., Da Ros, T., et al. (2010) · Nature Chemistry · doi:10.1038/nchem.761 · Cited by 503
Current Transients in Single Nanoparticle Collision Events
Xiao, X., Fan, F.-R. F., Zhou, J., & Bard, A. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8051393 · Cited by 451
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Metadata
- Authors
- Wightman, R. M.
- Venue
- Science
- Published
- 2006-03-17
- Volume
- 311
- Issue
- 5767
- Pages
- 1570-1574
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2111710127
- Cited by
- 439
- References
- 3
- FWCI
- 25.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Probing Cellular Chemistry in Biological Systems with Microelectrodes. https://app.cochat.ai/papers/10.1126/science.1120027
- The paper
- Wightman, R. M. (2006). Probing Cellular Chemistry in Biological Systems with Microelectrodes. Science. https://doi.org/10.1126/science.1120027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.