The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Label-Free, Single-Molecule Detection with Optical Microcavities
Abstract
Current single-molecule detection techniques require labeling the target molecule. We report a highly specific and sensitive optical sensor based on an ultrahigh quality ( Q ) factor ( Q > 10 8 ) whispering-gallery microcavity. The silica surface is functionalized to bind the target molecule; binding is detected by a resonant wavelength shift. Single-molecule detection is confirmed by observation of single-molecule binding events that shift the resonant frequency, as well as by the statistics for these shifts over many binding events. These shifts result from a thermo-optic mechanism. Additionally, label-free, single-molecule detection of interleukin-2 was demonstrated in serum. These experiments demonstrate a dynamic range of 10 12 in concentration, establishing the microcavity as a sensitive and versatile detector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Self-citationWeighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cited by
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Iqbal, M., Gleeson, M. A., Spaugh, B., Tybor, F., Gunn, W. G., Hochberg, M., Baehr-Jones, T., Bailey, R. C., & Gunn, L. C. (2010) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2032510 · Cited by 551
Fundamental limits and non-reciprocal approaches in non-Hermitian quantum sensing
Lau, H.-K., & Clerk, A. A. (2018) · Nature Communications · doi:10.1038/s41467-018-06477-7 · Cited by 380
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Self-citationPiliarik, M., & Sandoghdar, V. (2014) · Nature Communications · doi:10.1038/ncomms5495 · Cited by 332
Metadata
- Authors
- Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J.
- Venue
- Science
- Published
- 2007-08-10
- Volume
- 317
- Issue
- 5839
- Pages
- 783-787
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2017049373
- Cited by
- 1,141
- References
- 2
- FWCI
- 77.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-Free, Single-Molecule Detection with Optical Microcavities. https://app.cochat.ai/papers/10.1126/science.1145002
- The paper
- Armani, A. M., Kulkarni, R. P., Fraser, S. E., Flagan, R. C., & Vahala, K. J. (2007). Label-Free, Single-Molecule Detection with Optical Microcavities. Science. https://doi.org/10.1126/science.1145002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.