The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
The Force Needed to Move an Atom on a Surface
Open accessAbstract
Manipulation of individual atoms and molecules by scanning probe microscopy offers the ability of controlled assembly at the single-atom scale. However, the driving forces behind atomic manipulation have not yet been measured. We used an atomic force microscope to measure the vertical and lateral forces exerted on individual adsorbed atoms or molecules by the probe tip. We found that the force that it takes to move an atom depends strongly on the adsorbate and the surface. Our results indicate that for moving metal atoms on metal surfaces, the lateral force component plays the dominant role. Furthermore, measuring spatial maps of the forces during manipulation yielded the full potential energy landscape of the tip-sample interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Why gold is the noblest of all the metals
Hammer, B., & Norskov, J. K. (1995) · Nature · doi:10.1038/376238a0 · Cited by 3,935
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Confinement of Electrons to Quantum Corrals on a Metal Surface
Crommie, M. F., Lutz, C. P., & Eigler, D. M. (1993) · Science · doi:10.1126/science.262.5131.218 · Cited by 1,690
Self-citationSpin Coupling in Engineered Atomic Structures
Hirjibehedin, C. F., Lutz, C. P., & Heinrich, A. J. (2006) · Science · doi:10.1126/science.1125398 · Cited by 806
Self-citationHla, S.-W., Bartels, L., Meyer, G., & Rieder, K.-H. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2777 · Cited by 783
Accurate formulas for interaction force and energy in frequency modulation force spectroscopy
Sader, J. E., & Jarvis, S. P. (2004) · Applied Physics Letters · doi:10.1063/1.1667267 · Cited by 703
Noncontact Atomic Force Microscopy
(2002) · NanoScience and Technology · doi:10.1007/978-3-642-56019-4 · Cited by 507
Bartels, L., Meyer, G., & Rieder, K. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.697 · Cited by 490
Development of One-Dimensional Band Structure in Artificial Gold Chains
Nilius, N., Wallis, T. M., & Ho, W. (2002) · Science · doi:10.1126/science.1075242 · Cited by 456
Subatomic Features on the Silicon (111)-(7×7) Surface Observed by Atomic Force Microscopy
Giessibl, F. J., Hembacher, S., Bielefeldt, H., & Mannhart, J. (2000) · Science · doi:10.1126/science.289.5478.422 · Cited by 396
Self-citationAtom inlays performed at room temperature using atomic force microscopy
Sugimoto, Y., Abe, M., Hirayama, S., Oyabu, N., Custance, Ó., & Morita, S. (2005) · Nature Materials · doi:10.1038/nmat1297 · Cited by 382
Controlling the Dynamics of a Single Atom in Lateral Atom Manipulation
Stroscio, J. A., & Celotta, R. (2004) · Science · doi:10.1126/science.1102370 · Cited by 279
Chain Formation of Metal Atoms
Bahn, S. R., & Jacobsen, K. W. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.266101 · Cited by 259
Hölscher, H., Langkat, S. M., Schwarz, A., & Wiesendanger, R. (2002) · Applied Physics Letters · doi:10.1063/1.1525056 · Cited by 150
Disappearance of the Kondo resonance for atomically fabricated cobalt dimers
Chen, W., Jamneala, T., Madhavan, V., & Crommie, M. F. (1999) · Physical review. B, Condensed matter · doi:10.1103/physrevb.60.r8529 · Cited by 130
Controlled Atomic Doping of a Single C 60 Molecule
Yamachika, R., Grobis, M., Wachowiak, A., & Crommie, M. F. (2004) · Science · doi:10.1126/science.1095069 · Cited by 129
Sugimoto, Y., Jelı́nek, P., Pou, P. J., Abe, M., Morita, S., Pérez, R., & Custance, Ó. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.106104 · Cited by 116
Lateral manipulation of single atoms at semiconductor surfaces using atomic force microscopy
Oyabu, N., Sugimoto, Y., Abe, M., Custance, Ó., & Morita, S. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/3/021 · Cited by 106
Cited by
The Chemical Structure of a Molecule Resolved by Atomic Force Microscopy
Gross, L., Mohn, F., Moll, N., Liljeroth, P., & Meyer, G. (2009) · Science · doi:10.1126/science.1176210 · Cited by 1,842
Single-molecule junctions beyond electronic transport
Aradhya, S. V., & Venkataraman, L. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.91 · Cited by 862
Electromagnetic wireless nanosensor networks
Akyildiz, I. F., & Jornet, J. M. (2010) · Nano Communication Networks · doi:10.1016/j.nancom.2010.04.001 · Cited by 672
Recent advances in single-asperity nanotribology
Szlufarska, I., Chandross, M., & Carpick, R. W. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/12/123001 · Cited by 470
Fukuma, T., Ueda, Y., Yoshioka, S., & Asakawa, H. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.016101 · Cited by 464
Metadata
- Authors
- Ternes, M., Lutz, C. P., Hirjibehedin, C. F., Giessibl, F. J., & Heinrich, A. J.
- Venue
- Science
- Published
- 2008-02-22
- Volume
- 319
- Issue
- 5866
- Pages
- 1066-1069
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1987832809
- Cited by
- 454
- References
- 19
- FWCI
- 26.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.