The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Four-Dimensional Electron Microscopy
Abstract
Ultrafast Imaging: Optical microscopy is generally limited in resolution by the wavelength of light incident on the substrate. Because these wavelengths, even in the ultraviolet, are on the order of hundreds of nanometers, electron beams have long been used instead to probe structural detail at the smallest scale. While offering exceptional spatial resolution, electrons repel one another and so cannot be compressed in time as easily as a pulse of light. Electron microscopy has thus traditionally been a comparatively static characterization method. Zewail (p. 187 ) reviews recent technological developments in stripping down the electron pulses used for imaging that have been able to introduce time resolution of trillionths of a second to this spatially precise technique. Local transformations ranging from graphite film oscillations to iron phase transitions have been tracked in this manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
Thermodynamics versus Kinetics in Nanosynthesis
Wang, Y., He, J., Liu, C., Chong, W. H., & Chen, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201402986 · Cited by 497
Femtosecond electron diffraction: heralding the era of atomically resolved dynamics
Sciaini, G., & Miller, R. J. D. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/9/096101 · Cited by 485
Giannetti, C., Capone, M., Fausti, D., Fabrizio, M., Parmigiani, F., & Mihailovic, D. (2016) · Advances in Physics · doi:10.1080/00018732.2016.1194044 · Cited by 481
Ultrafast Spectroscopy: State of the Art and Open Challenges
Maiuri, M., Garavelli, M., & Cerullo, G. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.9b10533 · Cited by 460
Feist, A., Bach, N., Rubiano da Silva, N., Danz, T., Möller, M., Priebe, K. E., Domröse, T., Gatzmann, J. G., Rost, S., Schauss, J., et al. (2017) · Ultramicroscopy · doi:10.1016/j.ultramic.2016.12.005 · Cited by 425
Metadata
- Authors
- Zewail, A. H.
- Venue
- Science
- Published
- 2010-04-09
- Volume
- 328
- Issue
- 5975
- Pages
- 187-193
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2070951363
- Cited by
- 807
- References
- 3
- FWCI
- 25.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Four-Dimensional Electron Microscopy. https://app.cochat.ai/papers/10.1126/science.1166135
- The paper
- Zewail, A. H. (2010). Four-Dimensional Electron Microscopy. Science. https://doi.org/10.1126/science.1166135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.