The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
A Gating Charge Transfer Center in Voltage Sensors
Open accessAbstract
Open and Closed Case: Voltage-dependent ion channels are gated by voltage sensors that show a switchlike response to voltage differences across the membrane. Tao et al. (p. 67 ; see the cover) used mutagenesis, electrophysiology, and x-ray crystallography to gain insight into the molecular basis of this response in voltage-dependent potassium channels. An occluded site was identified that catalyzes translation of positive charges across the membrane. The closed channel appears to be associated with a distribution of conformations, depending on the degree of hyperpolarization of the membrane, whereas the open channel appears to be associated with a specific conformation. Thus, the transition of the ion channel from open to closed occurs over a very small voltage difference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crystal Structure of a Mammalian Voltage-Dependent Shaker Family K + Channel
Long, S. B., Campbell, E. B., & MacKinnon, R. (2005) · Science · doi:10.1126/science.1116269 · Cited by 2,124
Self-citationX-ray structure of a voltage-dependent K+ channel
Jiang, Y., Lee, A., Chen, J., Ruta, V., Cadene, M., Chait, B. T., & MacKinnon, R. (2003) · Nature · doi:10.1038/nature01580 · Cited by 1,797
Self-citationAtomic structure of a voltage-dependent K+ channel in a lipid membrane-like environment
Long, S. B., Tao, X., Campbell, E. B., & MacKinnon, R. (2007) · Nature · doi:10.1038/nature06265 · Cited by 1,411
Self-citationVoltage Sensor of Kv1.2: Structural Basis of Electromechanical Coupling
Long, S. B., Campbell, E. B., & MacKinnon, R. (2005) · Science · doi:10.1126/science.1116270 · Cited by 979
Self-citationThe principle of gating charge movement in a voltage-dependent K+ channel
Jiang, Y., Ruta, V., Chen, J., Lee, A., & MacKinnon, R. (2003) · Nature · doi:10.1038/nature01581 · Cited by 781
Self-citationCharge Movement Associated with the Opening and Closing of the Activation Gates of the Na Channels
Armstrong, C. M., & Bezanilla, F. (1974) · The Journal of General Physiology · doi:10.1085/jgp.63.5.533 · Cited by 741
Contribution of the S4 Segment to Gating Charge in the Shaker K+ Channel
Aggarwal, S. K., & MacKinnon, R. (1996) · Neuron · doi:10.1016/s0896-6273(00)80143-9 · Cited by 681
Self-citationPhosphoinositide phosphatase activity coupled to an intrinsic voltage sensor
Murata, Y., Iwasaki, H., Sasaki, M., Inaba, K., & Okamura, Y. (2005) · Nature · doi:10.1038/nature03650 · Cited by 673
Voltage-Sensing Residues in the S2 and S4 Segments of the Shaker K+ Channel
Seoh, S.-A., Sigg, D., Papazian, D. M., & Bezanilla, F. (1996) · Neuron · doi:10.1016/s0896-6273(00)80142-7 · Cited by 659
A voltage-gated proton-selective channel lacking the pore domain
Ramsey, I. S., Moran, M. M., Chong, J. A., & Clapham, D. E. (2006) · Nature · doi:10.1038/nature04700 · Cited by 612
Cited by
The crystal structure of a voltage-gated sodium channel
Payandeh, J., Scheuer, T., Zheng, N., & Catterall, W. A. (2011) · Nature · doi:10.1038/nature10238 · Cited by 1,429
Electric vehicle battery technologies: From present state to future systems
Manzetti, S., & Mariasiu, F. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.010 · Cited by 533
Crystal structure of an orthologue of the NaChBac voltage-gated sodium channel
Zhang, X., Ren, W., DeCaen, P., Yan, C., Tao, X., Tang, L., Wang, J., Hasegawa, K., Kumasaka, T., He, J., et al. (2012) · Nature · doi:10.1038/nature11054 · Cited by 466
Self-citationStructure of the human voltage-gated sodium channel Na v 1.4 in complex with β1
Pan, X., Li, Z., Zhou, Q., Shen, H., Wu, K., Huang, X., Chen, J., Zhang, J., Zhu, X., Lei, J., et al. (2018) · Science · doi:10.1126/science.aau2486 · Cited by 417
Structural basis of Nav1.7 inhibition by an isoform-selective small-molecule antagonist
Ahuja, S., Mukund, S., Deng, L., Khakh, K., Chang, E., Ho, H., Shriver, S., Young, C., Lin, S., Johnson, J. P., et al. (2015) · Science · doi:10.1126/science.aac5464 · Cited by 319
Metadata
- Authors
- Tao, X., Lee, A., Limapichat, W., Dougherty, D. A., & MacKinnon, R.
- Venue
- Science
- Published
- 2010-04-02
- Volume
- 328
- Issue
- 5974
- Pages
- 67-73
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2154420373
- Cited by
- 465
- References
- 24
- FWCI
- 13.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Gating Charge Transfer Center in Voltage Sensors. https://app.cochat.ai/papers/10.1126/science.1185954
- The paper
- Tao, X., Lee, A., Limapichat, W., Dougherty, D. A., & MacKinnon, R. (2010). A Gating Charge Transfer Center in Voltage Sensors. Science. https://doi.org/10.1126/science.1185954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.