The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Stretching Dielectric Elastomer Performance
Abstract
Devices using materials that deform in response to electricity are based on a phenomenon that was observed more than two centuries ago.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-Speed Electrically Actuated Elastomers with Strain Greater Than 100%
Pelrine, R., Kornbluh, R., Pei, Q., & Joseph, J. (2000) · Science · doi:10.1126/science.287.5454.836 · Cited by 3,283
Advances in Dielectric Elastomers for Actuators and Artificial Muscles
Brochu, P., & Pei, Q. (2010) · Macromolecular Rapid Communications · doi:10.1002/marc.200900425 · Cited by 1,387
Dielectric Elastomers as Electromechanical Transducers
(2008) · Elsevier eBooks · doi:10.1016/b978-0-08-047488-5.x0001-9 · Cited by 606
Stacked dielectric elastomer actuator for tensile force transmission
Kovacs, G., Düring, L., Michel, S., & Terrasi, G. (2009) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2009.08.027 · Cited by 373
Maximal energy that can be converted by a dielectric elastomer generator
Koh, S. J. A., Zhao, X., & Suo, Z. (2009) · Applied Physics Letters · doi:10.1063/1.3167773 · Cited by 325
Röntgen’s electrode-free elastomer actuators without electromechanical pull-in instability
Keplinger, C., Kaltenbrunner, M., Arnold, N., & Bauer, S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0913461107 · Cited by 232
Self-citationMetal Ion Implantation for the Fabrication of Stretchable Electrodes on Elastomers
Rosset, S., Niklaus, M., Dubois, P., & Shea, H. R. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801218 · Cited by 200
Polymeric, electrically tunable diffraction grating based on artificial muscles
Aschwanden, M., & Stemmer, A. (2006) · Optics Letters · doi:10.1364/ol.31.002610 · Cited by 112
Molecular composites with enhanced energy density for electroactive polymers
Stoyanov, H. Y., Kollosche, M., McCarthy, D. N., & Kofod, G. (2010) · Journal of Materials Chemistry · doi:10.1039/c0jm00519c · Cited by 102
Hydrostatically Coupled Dielectric Elastomer Actuators
Carpi, F., Frediani, G., & Rossi, D. D. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2021651 · Cited by 85
Self-citation
Cited by
Stretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754
Pneumatic Networks for Soft Robotics that Actuate Rapidly
Mosadegh, B., Polygerinos, P., Keplinger, C., Wennstedt, S., Shepherd, R. F., Gupta, U., Shim, J., Bertoldi, K., Walsh, C. J., & Whitesides, G. M. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303288 · Cited by 1,607
Tee, B. C.-K., Wang, C., Allen, R., & Bao, Z. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.192 · Cited by 1,419
Artificial Muscles from Fishing Line and Sewing Thread
Haines, C. S., Lima, M. D., Li, N., Spinks, G. M., Foroughi, J., Madden, J. D. W., Kim, S. H., Fang, S., Jung de Andrade, M., Göktepe, F., et al. (2014) · Science · doi:10.1126/science.1246906 · Cited by 1,350
Polygerinos, P., Correll, N., Morin, S. A., Mosadegh, B., Onal, C. D., Petersen, K., Cianchetti, M., Tolley, M. T., & Shepherd, R. F. (2017) · Advanced Engineering Materials · doi:10.1002/adem.201700016 · Cited by 1,063
Metadata
- Authors
- Carpi, F., Bauer, S., & De Rossi, D.
- Venue
- Science
- Published
- 2010-12-24
- Volume
- 330
- Issue
- 6012
- Pages
- 1759-1761
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2006877422
- Cited by
- 523
- References
- 10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.