The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Electrical Spiking in Escherichia coli Probed with a Fluorescent Voltage-Indicating Protein
Abstract
Introducing Bacterial Electrophysiology: Bacterial electrophysiology has been limited by the inability to measure the membrane potential of single cells. Kralj et al. (p. 345 ) engineered a class of voltage-sensitive fluorescent membrane proteins to perform electrophysiological measurements on individual intact bacteria. These measurements showed that Escherichia coli generate electrical spikes, reminiscent of action potentials in neurons. The response of electrical spiking in bacteria was assessed in response to a wide range of physical and chemical perturbations, and was correlated with efflux activity. In the future, the probe should be useful in determining the roles of membrane potential in a variety of medically, environmentally, and industrially important bacteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
Visualizing secretion and synaptic transmission with pH-sensitive green fluorescent proteins
Miesenböck, G., De Angelis, D. A., & Rothman, J. E. (1998) · Nature · doi:10.1038/28190 · Cited by 2,563
Bacterial Rhodopsin: Evidence for a New Type of Phototrophy in the Sea
Béjà, O., Aravind, L., Koonin, E. V., Suzuki, M. T., Hadd, A., Nguyen, L. P., Jovanovich, S. B., Gates, C. M., Feldman, R. A., Spudich, J. L., et al. (2000) · Science · doi:10.1126/science.289.5486.1902 · Cited by 1,532
Molecular and Cellular Approaches for Diversifying and Extending Optogenetics
Gradinaru, V., Zhang, F., Ramakrishnan, C., Mattis, J., Prakash, R., Diester, I., Goshen, I., Thompson, K. R., & Deisseroth, K. (2010) · Cell · doi:10.1016/j.cell.2010.02.037 · Cited by 1,018
Proteorhodopsin phototrophy in the ocean
Béjà, O., Spudich, E. N., Spudich, J. L., Leclerc, M., & DeLong, E. F. (2001) · Nature · doi:10.1038/35081051 · Cited by 802
Retinylidene Proteins: Structures and Functions from Archaea to Humans
Spudich, J. L., Yang, C.-S., Jung, K.-H., & Spudich, E. N. (2000) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.16.1.365 · Cited by 675
Pressure-sensitive ion channel in Escherichia coli.
Martinac, B., Buechner, M., Delcour, A. H., Adler, J., & Kung, C. (1987) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.84.8.2297 · Cited by 656
The respiratory chains of Escherichia coli
Ingledew, W. J., & Poole, R. K. (1984) · Microbiological Reviews · doi:10.1128/mmbr.48.3.222-271.1984 · Cited by 503
Functional Bionetworks from Nanoliter Water Droplets
Holden, M. A., Needham, D., & Bayley, H. (2007) · Journal of the American Chemical Society · doi:10.1021/ja072292a · Cited by 349
Novo, D., Perlmutter, N. G., Hunt, R. H., & Shapiro, H. M. (1999) · Cytometry · doi:10.1002/(sici)1097-0320(19990101)35:1<55::aid-cyto8>3.0.co;2-2 · Cited by 303
Proteorhodopsin is a Light-driven Proton Pump with Variable Vectoriality
Friedrich, T., Geibel, S., Kalmbach, R., Chizhov, I., Ataka, K., Heberle, J., Engelhard, M., & Bamberg, E. (2002) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)00696-4 · Cited by 249
Analytical Description of Transmembrane Voltage Induced by Electric Fields on Spheroidal Cells
Kotnik, T., & Miklavčič, D. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76325-9 · Cited by 242
Modified reconstitution method used in patch-clamp studies of Escherichia coli ion channels
Delcour, A. H., Martinac, B., Adler, J., & Kung, C. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82710-9 · Cited by 213
Martinac, B., Saimi, Y., & Kung, C. (2008) · Physiological Reviews · doi:10.1152/physrev.00005.2008 · Cited by 201
Haupts, U., Tittor, J., Bamberg, E., & Oesterhelt, D. (1997) · Biochemistry · doi:10.1021/bi962014g · Cited by 161
Bohnert, J. A., Karamian, B. A., & Nikaido, H. (2010) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00620-10 · Cited by 155
Powering the flagellar motor of Escherichia coli with an external voltage source
Fung, D. C., & Berg, H. C. (1995) · Nature · doi:10.1038/375809a0 · Cited by 137
Nonconsecutive disulfide bond formation in an essential integral outer membrane protein
Ruiz, N., Chng, S., Hiniker, A. O., Kahne, D. E., & Silhavy, T. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1007319107 · Cited by 134
Lo, C., Leake, M. C., Piližota, T., & Berry, R. M. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.095265 · Cited by 103
Mode of inhibition of sodium azide on H+‐ATPase of Escherichia coli
Noumi, T., Maeda, M., & Futai, M. (1987) · FEBS Letters · doi:10.1016/0014-5793(87)81526-0 · Cited by 95
Schmies, G., Lüttenberg, B., Chizhov, I. V., Engelhard, M., Becker, A., & Bamberg, E. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76654-9 · Cited by 82
Chemical transitions measured by spectra and resolved using singular value decomposition
Shrager, R. I. (1986) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(86)80026-0 · Cited by 82
Measuring the Induced Membrane Voltage with Di-8-ANEPPS
Pucihar, G., Kotnik, T., & Damijan Miklavčič, A. (2009) · Journal of Visualized Experiments · doi:10.3791/1659 · Cited by 49
Imasheva, E. S., Shimono, K., Balashov, S. P., Wang, J. M., Zadok, U., Sheves, M., Kamo, N., & Lanyi, J. Κ. (2005) · Biochemistry · doi:10.1021/bi050438h · Cited by 32
Measuring the Induced Membrane Voltage with Di-8-ANEPPS
Pucihar, G., Kotnik, T., & Damijan Miklavčič, A. (2009) · Journal of Visualized Experiments · doi:10.3791/1659-v · Cited by 5
Cited by
Ion channels enable electrical communication in bacterial communities
Prindle, A., Liu, J., Asally, M., Ly, S., Garcia-Ojalvo, J., & Süel, G. M. (2015) · Nature · doi:10.1038/nature15709 · Cited by 790
From the neuron doctrine to neural networks
Yuste, R. (2015) · Nature Reviews Neuroscience · doi:10.1038/nrn3962 · Cited by 754
Jin, L., Han, Z., Platisa, J., Wooltorton, J. R. A., Cohen, L. B., & Pieribone, V. A. (2012) · Neuron · doi:10.1016/j.neuron.2012.06.040 · Cited by 539
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
Optical recording of action potentials in mammalian neurons using a microbial rhodopsin
Kralj, J. M., Douglass, A. D., Hochbaum, D. R., Maclaurin, D., & Cohen, A. E. (2012) · Nature Methods · doi:10.1038/nmeth.1782 · Cited by 460
Self-citation
Metadata
- Authors
- Kralj, J. M., Hochbaum, D. R., Douglass, A. D., & Cohen, A. E.
- Venue
- Science
- Published
- 2011-07-15
- Volume
- 333
- Issue
- 6040
- Pages
- 345-348
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1994647098
- Cited by
- 378
- References
- 25
- FWCI
- 10.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.