The DOI matches its Crossref record.
Somatically Evoked Magnetic Fields of the Human Brain
Abstract
The human brain is found to produce a magnetic field near the scalp which varies in synchrony with periodic electrical stimulation applied to a finger. Use of a highly sensitive superconducting quantum interference device as a magnetic field detector reveals that the brain's field is sharply localized over the primary projection area of the sensory cortex contralateral to the digit being stimulated. The phase of the response at the stimulus frequency varies monotonically with the repetition rate and at intermediate frequencies yields a latency of approximately 70 milliseconds for cortical response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Visualization of Magnetoencephalographic Data Using Minimum Current Estimates
Uutela, K., Hämäläinen, M., & Somersalo, E. (1999) · NeuroImage · doi:10.1006/nimg.1999.0454 · Cited by 512
Theta oscillations index human hippocampal activation during a working memory task
Tesche, C. D., & Karhu, J. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.2.919 · Cited by 496
Functional Organization of the Human First and Second Somatosensory Cortices: a Neuromagnetic Study
Hari, R., Karhu, J., Hämäläinen, M., Knuutila, J., Salonen, O., Sams, M., & Vilkman, V. (1993) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.1993.tb00536.x · Cited by 476
Hari, R., Kaila, K., Katila, T., Tuomisto, T., & Varpula, T. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90041-4 · Cited by 364
Recursive MUSIC: A framework for EEG and MEG source localization
Mosher, J. C., & Leahy, R. M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.725331 · Cited by 362
Tesche, C. D., Uusitalo, M. A., Ilmoniemi, R. J., Huotilainen, M., Kajola, M., & Salonen, O. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00064-6 · Cited by 355
Somatosensory evoked cerebral magnetic fields from SI and SII in man
Hari, R., Reinikainen, K., Kaukoranta, E., Hämäläinen, M., Ilmoniemi, R., Penttinen, A., Salminen, J., & Teszner, D. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90126-3 · Cited by 341
Magnetoencephalography in the study of human somatosensory cortical processing
Hari, R., & Forss, N. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0470 · Cited by 338
Somatosensory Homunculus as Drawn by MEG
Nakamura, A., Yamada, T., Goto, A., Kato, T., Ito, K., Abe, Y., Kachi, T., & Kakigi, R. (1998) · NeuroImage · doi:10.1006/nimg.1998.0332 · Cited by 338
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Self-citationWood, C. C., Cohen, D., Cuffin, B. N., Yarita, M., & Allison, T. (1985) · Science · doi:10.1126/science.3975600 · Cited by 320
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
Comparison of the magnetoencephalogram and electroencephalogram
Neil Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 274
Jones, S. R., Pritchett, D. L., Stufflebeam, S. M., Hämäläinen, M., & Moore, C. I. (2007) · The Journal of Neuroscience · doi:10.1523/jneurosci.0482-07.2007 · Cited by 160
Metadata
- Authors
- Brenner, D., Lipton, J., Kaufman, L., & Williamson, S. J.
- Venue
- Science
- Published
- 1978-01-06
- Volume
- 199
- Issue
- 4324
- Pages
- 81-83
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2027533821
- Cited by
- 227
- References
- 0
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.