The DOI matches its Crossref record.
The Scanning Ion-Conductance Microscope
Abstract
A scanning ion-conductance microscope (SICM) has been developed that can image the topography of nonconducting surfaces that are covered with electrolytes. The probe of the SICM is an electrolyte-filled micropipette. The flow of ions through the opening of the pipette is blocked at short distances between the probe and the surface, thus limiting the ion conductance. A feedback mechanism can be used to maintain a given conductance and in turn determine the distance to the surface. The SICM can also sample and image the local ion currents above the surfaces. To illustrate its potential for imaging ion currents through channels in membranes, a topographic image of a membrane filter with 0.80-micrometer pores and an image of the ion currents flowing through such pores are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ebejer, N., Güell, A. G., Lai, S. C. S., McKelvey, K., Snowden, M. E., & Unwin, P. R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092650 · Cited by 355
Dammak, L., Fouilloux, J., Bdiri, M., Larchet, C., Renard, E., Baklouti, L., Sarapulova, V., Kozmai, A., & Pismenskaya, N. (2021) · Membranes · doi:10.3390/membranes11100789 · Cited by 93
Metadata
- Authors
- Hansma, P. K., Drake, B., Marti, O., Gould, S. A. C., & Prater, C. B.
- Venue
- Science
- Published
- 1989-02-03
- Volume
- 243
- Issue
- 4891
- Pages
- 641-643
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2077813193
- Cited by
- 849
- References
- 0
- FWCI
- 12.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Scanning Ion-Conductance Microscope. https://app.cochat.ai/papers/10.1126/science.2464851
- The paper
- Hansma, P. K., Drake, B., Marti, O., Gould, S. A. C., & Prater, C. B. (1989). The Scanning Ion-Conductance Microscope. Science. https://doi.org/10.1126/science.2464851
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.