The DOI matches its Crossref record.
Alterations of Single Molecule Fluorescence Lifetimes in Near-Field Optical Microscopy
Abstract
Fluorescence lifetimes of single Rhodamine 6G molecules on silica surfaces were measured with pulsed laser excitation, time-correlated single photon counting, and near-field scanning optical microscopy (NSOM). The fluorescence lifetime varies with the position of a molecule relative to a near-field probe. Qualitative features of lifetime decreases are consistent with molecular excited state quenching effects near metal surfaces. The technique of NSOM provides a means of altering the environment of a single fluorescent molecule and its decay kinetics in a repeatable fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Probing Individual Molecules with Confocal Fluorescence Microscopy
Nie, S., Chiu, D. T., & Zare, R. N. (1994) · Science · doi:10.1126/science.7973650 · Cited by 549
Bout, D. A. V., Yip, W.-T., Hu, D., Fu, D.-K., Swager, T. M., & Barbara, P. F. (1997) · Science · doi:10.1126/science.277.5329.1074 · Cited by 521
Near-Field Scanning Optical Microscopy
Dunn, R. C. (1999) · Chemical Reviews · doi:10.1021/cr980130e · Cited by 508
Controlled non-classical photon emission from single conjugated polymer molecules
Hollars, C. W., Lane, S. M., & Huser, T. (2003) · Chemical Physics Letters · doi:10.1016/s0009-2614(03)00091-5 · Cited by 96
Metadata
- Authors
- Ambrose, W. P., Goodwin, P. M., Keller, R. A., & Martin, J. C.
- Venue
- Science
- Published
- 1994-07-15
- Volume
- 265
- Issue
- 5170
- Pages
- 364-367
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1983312070
- Cited by
- 341
- References
- 0
- FWCI
- 34.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alterations of Single Molecule Fluorescence Lifetimes in Near-Field Optical Microscopy. https://app.cochat.ai/papers/10.1126/science.265.5170.364
- The paper
- Ambrose, W. P., Goodwin, P. M., Keller, R. A., & Martin, J. C. (1994). Alterations of Single Molecule Fluorescence Lifetimes in Near-Field Optical Microscopy. Science. https://doi.org/10.1126/science.265.5170.364
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.