The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Mechanics of Stimulated Neutrophils: Cell Stiffening Induces Retention in Capillaries
Abstract
The effect of peptide chemoattractants on neutrophil mechanical properties was studied to test the hypothesis that stimulated neutrophils (diameter, 8 micrometers) are retained in pulmonary capillaries (5.5 micrometers) as a result of a decreased ability of the cell to deform within the capillary in response to the hydrodynamic forces of the bloodstream. Increased neutrophil stiffness, actin assembly, and retention in both 5-micrometer pores and the pulmonary vasculature were seen in response to N -formyl-methionyl-leucyl-phenylalanine. These changes were abolished in cells that had been incubated with 2 micromolar cytochalasin D, an agent that disrupts cellular actin organization. A monoclonal antibody directed at the CD11-CD18 adhesive glycoprotein complex did not inhibit the increase in stiffness or retention in pores. These data suggest that neutrophil stiffening may be both necessary and sufficient for the retention that is observed. Hence, neutrophil sequestration in lung and other capillaries in the acute inflammatory process may be the result of increased stiffness stimulated by chemoattractants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of cell shape in growth control
Folkman, J., & Moscona, A. (1978) · Nature · doi:10.1038/273345a0 · Cited by 2,422
Leukocyte capillary plugging in myocardial ischemia and reperfusion in the dog.
Engler, R. L., Schmid‐Schönbein, G. W., & Pavelec, R. S. (1983) · PubMed Central · Cited by 855
Haslett, C., Guthrie, L. A., Kopaniak, M. M., Johnston, R. B., & Henson, P. M. (1985) · PubMed Central · Cited by 779
Craddock, P. R., Hammerschmidt, D., White, J. G., Dalmosso, A. P., & Jacob, H. S. (1977) · Journal of Clinical Investigation · doi:10.1172/jci108763 · Cited by 685
Smedly, L. A., Tonnesen, M. G., Sandhaus, R. A., Haslett, C., Guthrie, L. A., Johnston, R. B., Henson, P. M., & Worthen, G. S. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112426 · Cited by 567
Self-citationVedder, N. B., Winn, R. K., Rice, C. L., Chi, E. Y., Arfors, K. E., & Harlan, J. M. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113407 · Cited by 425
Passive mechanical properties of human leukocytes
Schmid-Schönbein, G. W., Sung, K. L., Tözeren, H., Skalak, R., & Chien, S. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84726-1 · Cited by 417
Howard, T. H., & Oresajo, C. O. (1985) · The Journal of cell biology · doi:10.1083/jcb.101.3.1078 · Cited by 311
Morphometry of human leukocytes
Gw, S.-S., Shih, Y., & Chien, S. (1980) · Blood · doi:10.1182/blood.v56.5.866.866 · Cited by 308
Beatty, P. G., Ledbetter, J. A., Martin, P. J., Price, T. H., & Hansen, J. A. (1983) · The Journal of Immunology · doi:10.4049/jimmunol.131.6.2913 · Cited by 296
Neutrophil kinetics and lung injury
Hogg, J. C. (1987) · Physiological Reviews · doi:10.1152/physrev.1987.67.4.1249 · Cited by 287
Signal transduction and cytoskeletal activation in the neutrophil.
Omann, G. M., Allen, R. A., Bokoch, G. M., Painter, R. G., Traynor, A. E., & Sklar, L. A. (1987) · Physiological Reviews · doi:10.1152/physrev.1987.67.1.285 · Cited by 280
Cellular Mechanics as an Indicator of Cytoskeletal Structure and Function
Elson, E. L. (1988) · Annual Review of Biophysics and Biophysical Chemistry · doi:10.1146/annurev.bb.17.060188.002145 · Cited by 235
Self-citationCytochalasin B and the structure of actin gels
Hartwig, J. H., & Stossel, T. P. (1979) · Journal of Molecular Biology · doi:10.1016/0022-2836(79)90366-8 · Cited by 234
Worthen, G. S., Haslett, C., Rees, A. J., Gumbay, R. S., Henson, J. E., & Henson, P. M. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.1.19 · Cited by 228
Self-citationEvans, E., & Kukan, B. (1984) · Blood · doi:10.1182/blood.v64.5.1028.1028 · Cited by 188
Chemotactic peptide-induced changes in neutrophil actin conformation.
Wallace, P. J., Wersto, R. P., Packman, C. H., & Lichtman, M. A. (1984) · The Journal of cell biology · doi:10.1083/jcb.99.3.1060 · Cited by 180
Physiological neutrophil sequestration in the lung: visual evidence for localization in capillaries
Lien, D. C., Wagner, W. W., Capen, R. L., Haslett, C., Hanson, W. L., Hofmeister, S. E., Henson, P. M., & Worthen, G. S. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.62.3.1236 · Cited by 176
Self-citationHaslett, C., Worthen, G. S., Giclas, P. C., Morrison, D. C., Henson, J. E., & Henson, P. M. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.1.9 · Cited by 159
Self-citationFlorey, H. W., & Grant, L. (1961) · The Journal of Pathology and Bacteriology · doi:10.1002/path.1700820103 · Cited by 119
Ismail, G., Morganroth, M. L., Rf, T., & Boxer, L. A. (1987) · PubMed · doi:10.1182/blood.v69.4.1167.1167 · Cited by 93
Martin, B. A., Wright, J. R., Thommasen, H. V., & Hogg, J. C. (1982) · Journal of Clinical Investigation · doi:10.1172/jci110567 · Cited by 89
Neutrophil retention in model capillaries: deformability, geometry, and hydrodynamic forces
Downey, G. P., & Worthen, G. S. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.4.1861 · Cited by 89
Self-citationSandison, J. C. (1932) · The Anatomical Record · doi:10.1002/ar.1090540110 · Cited by 63
Influence of physicochemical factors on rheology of human neutrophils
Sung, K. L. P., Schmid‐Schönbein, G. W., Skalak, R., Schuessler, G. B., Usami, S., & Chien, S. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84495-0 · Cited by 60
Meyrick, B. O., & Brigham, K. L. (1984) · PubMed · Cited by 58
Effects of shear stress on adhesive interaction between neutrophils and cultured endothelial cells
Worthen, G. S., Smedly, L. A., Tonnesen, M. G., et al. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.63.5.2031 · Cited by 58
Self-citationDamiano, V. V., Cohen, A. B., Tsang, A., et al. (1980) · PubMed · Cited by 42
Intravascular anatomy of blood cells in man
Brånemark, P. (1971) · Medical Entomology and Zoology · Cited by 37
Cited by
Guck, J., Schinkinger, S., Lincoln, B., Wottawah, F., Ebert, S., Romeyke, M., Lenz, D., Erickson, H. M., Ananthakrishnan, R., Mitchell, D., et al. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.045476 · Cited by 1,417
Contribution of Neutrophils to Acute Lung Injury
Grommes, J., & Soehnlein, O. (2011) · Molecular Medicine · doi:10.2119/molmed.2010.00138 · Cited by 1,313
Hydrodynamic stretching of single cells for large population mechanical phenotyping
Gossett, D. R., Tse, H. T. K., Lee, S. A., Ying, Y., Lindgren, A. G., Yang, O. O., Rao, J., Clark, A. T., & Di Carlo, D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200107109 · Cited by 775
Cell Stiffness Is a Biomarker of the Metastatic Potential of Ovarian Cancer Cells
Xu, W., Mezencev, R., Kim, B., Wang, L., McDonald, J., & Sulchek, T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046609 · Cited by 760
Mechanical models for living cells—a review
Lim, C. T., Zhou, E. H., & Quek, S. T. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.008 · Cited by 719
Metadata
- Authors
- Worthen, G. S., Schwab, B., Elson, E. L., & Downey, G. P.
- Venue
- Science
- Published
- 1989-07-14
- Volume
- 245
- Issue
- 4914
- Pages
- 183-186
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1988158019
- Cited by
- 597
- References
- 29
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.