The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Imaging Precessional Motion of the Magnetization Vector
Abstract
We report on imaging of three-dimensional precessional orbits of the magnetization vector in a magnetic field by means of a time-resolved vectorial Kerr experiment that measures all three components of the magnetization vector with picosecond resolution. Images of the precessional mode taken with submicrometer spatial resolution reveal that the dynamical excitation in this time regime roughly mirrors the symmetry of the underlying equilibrium spin configuration and that its propagation has a non-wavelike character. These results should form the basis for realistic models of the magnetization dynamics in a largely unexplored but technologically increasingly relevant time scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bloch, F. (1946) · Physical Review · doi:10.1103/physrev.70.460 · Cited by 3,676
On the Theory of Ferromagnetic Resonance Absorption
Kittel, C. (1948) · Physical Review · doi:10.1103/physrev.73.155 · Cited by 2,727
Theory of the Structure of Ferromagnetic Domains in Films and Small Particles
Kittel, C. (1946) · Physical Review · doi:10.1103/physrev.70.965 · Cited by 1,425
Room-Temperature Spin Memory in Two-Dimensional Electron Gases
Kikkawa, J. M., Smorchkova, I. P., Samarth, N., & Awschalom, D. D. (1997) · Science · doi:10.1126/science.277.5330.1284 · Cited by 536
Hiebert, W. K., Stankiewicz, A., & Freeman, M. R. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.1134 · Cited by 353
Minimum Field Strength in Precessional Magnetization Reversal
Back, C. H., Allenspach, R., Weber, W., Parkin, S. S. P., Weller, D., Garwin, E. L., & Siegmann, H. C. (1999) · Science · doi:10.1126/science.285.5429.864 · Cited by 293
Self-citationSubnanosecond magnetization dynamics measured by the second-harmonic magneto-optic Kerr effect
Crawford, T., Silva, T. J., Teplin, C. W., et al. (1999) · Applied Physics Letters · doi:10.1063/1.123353 · Cited by 88
Picosecond time-resolved magnetization dynamics of thin-film heads
Freeman, M. R., & Smyth, J. F. (1996) · Journal of Applied Physics · doi:10.1063/1.361896 · Cited by 82
Observation of ferromagnetic resonance in the time domain
Hicken, R. J., & Wu, J. (1999) · Journal of Applied Physics · doi:10.1063/1.370414 · Cited by 38
Cited by
Ordered magnetic nanostructures: fabrication and properties
Martı́n, J. I., Nogués, J., Liu, K., Vicent, J. L., & Schuller, I. K. (2003) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00898-3 · Cited by 889
Ultrafast precessional magnetization reversal by picosecond magnetic field pulse shaping
Gerrits, T., van den Berg, H. A. M., Hohlfeld, J., Bär, L., & Rasing, T. (2002) · Nature · doi:10.1038/nature00905 · Cited by 461
Bifurcation in precessional switching
Acremann, Y., Back, C. H., Buess, M., Pescia, D., & Pokrovsky, V. (2001) · Applied Physics Letters · doi:10.1063/1.1407299 · Cited by 34
Self-citation
Metadata
- Authors
- Acremann, Y., Back, C. H., Buess, M., Portmann, O., Vaterlaus, A., Pescia, D., & Melchior, H.
- Venue
- Science
- Published
- 2000-10-20
- Volume
- 290
- Issue
- 5491
- Pages
- 492-495
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1970526884
- Cited by
- 252
- References
- 9
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging Precessional Motion of the Magnetization Vector. https://app.cochat.ai/papers/10.1126/science.290.5491.492
- The paper
- Acremann, Y., Back, C. H., Buess, M., Portmann, O., Vaterlaus, A., Pescia, D., & Melchior, H. (2000). Imaging Precessional Motion of the Magnetization Vector. Science. https://doi.org/10.1126/science.290.5491.492
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.