The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Ultrasensitive Stain for Proteins in Polyacrylamide Gels Shows Regional Variation in Cerebrospinal Fluid Proteins
Abstract
A new silver stain for electrophoretically separated polypeptides can be rapidly and easily used and can detect as little as 0.01 nanogram of protein per square millimeter. When employed with two-dimensional electrophoresis, it should permit qualitative and quantitative characterization of protein distributions in body fluids and tissues. It has been used to demonstrate regional variations in cerebrospinal fluid proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
A highly sensitive silver stain for detecting proteins and peptides in polyacrylamide gels
Switzer, R. C., Merril, C. R., & Shifrin, S. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90732-2 · Cited by 1,085
Self-citationTwo-dimensional gel electrophoresis of cerebrospinal fluid proteins.
Goldman, D. A., Merril, C. R., & Ebert, M. H. (1980) · Clinical Chemistry · doi:10.1093/clinchem/26.9.1317 · Cited by 108
Self-citationSeparation of cerebrospinal fluid specific proteins — A methodological study
Wikkelsø, C., Blomstrand, C., & Rönnbäck, L. (1980) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(80)90132-x · Cited by 19
Cited by
Morrissey, J. H. (1981) · Analytical Biochemistry · doi:10.1016/0003-2697(81)90783-1 · Cited by 4,061
Silver staining of proteins in polyacrylamide gels
Wray, W., Boulikas, T., Wray, V. P., & Hancock, R. (1981) · Analytical Biochemistry · doi:10.1016/0003-2697(81)90179-2 · Cited by 3,504
A sensitive silver stain for detecting lipopolysaccharides in polyacrylamide gels
Tsai, C.-M., & Frasch, C. E. (1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90673-x · Cited by 3,067
Fast and sensitive silver staining of DNA in polyacrylamide gels
Bassam, B. J., Caetano-Anollés, G., & Gresshoff, P. M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90120-i · Cited by 2,840
Blue silver: A very sensitive colloidal Coomassie G‐250 staining for proteome analysis
Candiano, G., Bruschi, M., Musante, L., Santucci, L., Ghiggeri, G. M., Carnemolla, B., Orecchia, P., Zardi, L., & Righetti, P. G. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200305844 · Cited by 1,927
Metadata
- Authors
- Merril, C. R., Goldman, D., Sedman, S. A., & Ebert, M. H.
- Venue
- Science
- Published
- 1981-03-27
- Volume
- 211
- Issue
- 4489
- Pages
- 1437-1438
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2014321075
- Cited by
- 2,933
- References
- 4
- FWCI
- 124.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.