The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Relaxor ferroelectric polymer exhibits ultrahigh electromechanical coupling at low electric field
Open accessAbstract
Electromechanical (EM) coupling—the conversion of energy between electric and mechanical forms—in ferroelectrics has been used for a broad range of applications. Ferroelectric polymers have weak EM coupling that severely limits their usefulness for applications. We introduced a small amount of fluorinated alkyne (FA) monomers (<2 mol %) in relaxor ferroelectric poly(vinylidene fluoride-trifluoroethylene-chlorofluoroethylene) (PVDF-TrFE-CFE) terpolymer that markedly enhances the polarization change with strong EM coupling while suppressing other polarization changes that do not contribute to it. Under a low–dc bias field of 40 megavolts per meter, the relaxor tetrapolymer has an EM coupling factor ( k 33 ) of 88% and a piezoelectric coefficient ( d 33 ) >1000 picometers per volt. These values make this solution-processed polymer competitive with ceramic oxide piezoelectrics, with the potential for use in distinct applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precision and efficiency in solid-state pseudopotential calculations
Prandini, G., Marrazzo, A., Castelli, I. E., Mounet, N., & Marzari, N. (2018) · npj Computational Materials · doi:10.1038/s41524-018-0127-2 · Cited by 917
Cited by
Costa, C. M., Cardoso, V. F., Martins, P., Correia, D. M., Gonçalves, R., Costa, P., Correia, V., Ribeiro, C., Fernandes, M. M., Martins, P. M., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00196 · Cited by 498
Biodegradable ferroelectric molecular crystal with large piezoelectric response
Zhang, H.-Y., Tang, Y.-Y., Gu, Z.-X., Wang, P., Chen, X.-G., Lv, H.-P., Li, P.-F., Jiang, Q., Gu, N., Ren, S., et al. (2024) · Science · doi:10.1126/science.adj1946 · Cited by 267
Self-citationFluoropolymer ferroelectrics: Multifunctional platform for polar-structured energy conversion
Qian, X., Chen, X., Zhu, L., & Zhang, Q. M. (2023) · Science · doi:10.1126/science.adg0902 · Cited by 265
Self-citation
Metadata
- Authors
- Chen, X., Qin, H., Qian, X., Zhu, W., Li, B., Zhang, B., Lu, W., Li, R., Zhang, S., Zhu, L., Domingues Dos Santos, F., Bernholc, J., & Zhang, Q. M.
- Venue
- Science
- Published
- 2022-03-25
- Volume
- 375
- Issue
- 6587
- Pages
- 1418-1422
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W4221118722
- Cited by
- 247
- References
- 1
- FWCI
- 13.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relaxor ferroelectric polymer exhibits ultrahigh electromechanical coupling at low electric field. https://app.cochat.ai/papers/10.1126/science.abn0936
- The paper
- Chen, X., Qin, H., Qian, X., Zhu, W., Li, B., Zhang, B., Lu, W., Li, R., Zhang, S., Zhu, L., Domingues Dos Santos, F., Bernholc, J., & Zhang, Q. M. (2022). Relaxor ferroelectric polymer exhibits ultrahigh electromechanical coupling at low electric field. Science. https://doi.org/10.1126/science.abn0936
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.