The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
An automated smartphone-based diagnostic assay for point-of-care semen analysis
Open accessAbstract
This work demonstrates that a low-cost smartphone accessory can be used for home-based male infertility screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513 · cited 2×
“Passing-Bablok regression analysis (29) (n = 56) showed an A intercept value of −0.”
BackgroundMethodFifteen years of Belgian experience with external quality assessment of semen analysis
Punjabi, U., Wyns, C., Mahmoud, A., Vernelen, K., China, B., & Verheyen, G. (2016) · Andrology · doi:10.1111/andr.12230 · Cited by 64
Cited by
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 335
Biosensors and Microfluidic Biosensors: From Fabrication to Application
Kulkarni, M. B., Ayachit, N. H., & Aminabhavi, T. M. (2022) · Biosensors · doi:10.3390/bios12070543 · Cited by 281
Discovering Cell-Adhesion Peptides in Tissue Engineering: Beyond RGD
Huettner, N., Dargaville, T. R., & Forget, A. (2018) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.01.008 · Cited by 263
Wang, B., Li, Y., Zhou, M., Han, Y., Zhang, M., Gao, Z., Liu, Z., Chen, P., Du, W., Zhang, X., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-36017-x · Cited by 259
Metadata
- Authors
- Kanakasabapathy, M. K., Sadasivam, M., Singh, A., Preston, C., Thirumalaraju, P., Venkataraman, M., Bormann, C. L., Draz, M. S., Petrozza, J. C., & Shafiee, H.
- Venue
- Science Translational Medicine
- Published
- 2017-03-22
- Volume
- 9
- Issue
- 382
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2599086938
- Cited by
- 203
- References
- 3
- FWCI
- 20.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An automated smartphone-based diagnostic assay for point-of-care semen analysis. https://app.cochat.ai/papers/10.1126/scitranslmed.aai7863
- The paper
- Kanakasabapathy, M. K., Sadasivam, M., Singh, A., Preston, C., Thirumalaraju, P., Venkataraman, M., Bormann, C. L., Draz, M. S., Petrozza, J. C., & Shafiee, H. (2017). An automated smartphone-based diagnostic assay for point-of-care semen analysis. Science Translational Medicine. https://doi.org/10.1126/scitranslmed.aai7863
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.