Abstract

Smartphone-based point-of-care testing (POCT) is rapidly emerging as a potential alternative to the traditional laboratory-based diagnostic testing owing to economic considerations and availability of medical equipment especially in resource-limited areas. A smartphone, combined with a biosensor and other related accessories, can offer high accuracy and sensitivity for medical testing. Moreover, the ubiquity of smartphone has propelled the development considerably, and accordingly research in recent years has shown promising progress in POCT. Here, we used samples (blood, urine, sweat, saliva and tears) of liquid biopsy as the standard for classification of smartphone-based POCT devices, considering that these samples contain multiple biomarkers of serious diseases. The colorimetric, fluorescent, brightfield, and electrochemical methods were utilized to examine these samples. We performed a comprehensive review of the development of smartphone-based POCT devices over the past two years (2017-2018) and assessed their relative merits and drawbacks. Based on the progress of POCT development, it illustrates that the various technological and economical requirements are urgent and tremendous. The tendency of high-quality, low-cost smartphone-based POCT devices, feature of biosensors (paper-based sensor, flexible device, microfluidic chip, et al.) currently widely used in POCT and recommendations of future works were summarized.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2019.01.068

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 335

Metadata

Authors
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-05
Volume
132
Pages
17-37
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2915843262
Cited by
335
References
9
FWCI
15.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018). https://app.cochat.ai/papers/10.1016/j.bios.2019.01.068
The paper
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019). Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018). Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.01.068

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.