The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Abstract
Smartphone-based point-of-care testing (POCT) is rapidly emerging as a potential alternative to the traditional laboratory-based diagnostic testing owing to economic considerations and availability of medical equipment especially in resource-limited areas. A smartphone, combined with a biosensor and other related accessories, can offer high accuracy and sensitivity for medical testing. Moreover, the ubiquity of smartphone has propelled the development considerably, and accordingly research in recent years has shown promising progress in POCT. Here, we used samples (blood, urine, sweat, saliva and tears) of liquid biopsy as the standard for classification of smartphone-based POCT devices, considering that these samples contain multiple biomarkers of serious diseases. The colorimetric, fluorescent, brightfield, and electrochemical methods were utilized to examine these samples. We performed a comprehensive review of the development of smartphone-based POCT devices over the past two years (2017-2018) and assessed their relative merits and drawbacks. Based on the progress of POCT development, it illustrates that the various technological and economical requirements are urgent and tremendous. The tendency of high-quality, low-cost smartphone-based POCT devices, feature of biosensors (paper-based sensor, flexible device, microfluidic chip, et al.) currently widely used in POCT and recommendations of future works were summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Wearable and flexible sensors for user-interactive health-monitoring devices
Ha, M., Lim, S., & Ko, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c8tb01063c · Cited by 352
Stretchable wireless system for sweat pH monitoring
Dang, W., Manjakkal, L., Navaraj, W. T., Lorenzelli, L., Vinciguerra, V., & Dahiya, R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.025 · Cited by 326
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Sekine, Y., Kim, S. B., Zhang, Y., Bandodkar, A. J., Xu, S., Choi, J., Irie, M., Ray, T. R., Kohli, P., Kozai, N., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00530c · Cited by 242
The Value of In Vitro Diagnostic Testing in Medical Practice: A Status Report
Rohr, U.-P., Binder, C., Dieterle, T., Giusti, F., Messina, C. G. M., Toerien, E., Moch, H., & Schäfer, H. H. (2016) · PLOS ONE · doi:10.1371/journal.pone.0149856 · Cited by 229
Paper-based microfluidic system for tear electrolyte analysis
Yetisen, A. K., Jiang, N., Tamayol, A., Ruiz-Esparza, G. U., Zhang, Y. S., Medina-Pando, S., Gupta, A., Wolffsohn, J. S., Butt, H., Khademhosseini, A., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01450j · Cited by 151
Smartphone based non-invasive salivary glucose biosensor
Soni, A., & Jha, S. K. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.10.003 · Cited by 143
Cited by
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Jain, S., Nehra, M., Kumar, R., Dilbaghi, N., Hu, T., Kumar, S., Kaushik, A., & Li, C.-Z. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113074 · Cited by 357
Yan, T., Zhang, G., Chai, H., Qu, L., & Zhang, X. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.753692 · Cited by 59
Mobile Health (mHealth) Viral Diagnostics Enabled with Adaptive Adversarial Learning
Shokr, A., Pacheco, L. G. C., Thirumalaraju, P., Kanakasabapathy, M. K., Gandhi, J., Kartik, D., Silva, F. S. R., Erdogmus, E., Kandula, H., Luo, S., et al. (2021) · ACS Nano · doi:10.1021/acsnano.0c06807 · Cited by 45
Metadata
- Authors
- Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 132
- Pages
- 17-37
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2915843262
- Cited by
- 335
- References
- 9
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018). https://app.cochat.ai/papers/10.1016/j.bios.2019.01.068
- The paper
- Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019). Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018). Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.01.068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.