The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Seasonal Variations of Indoor Microbial Exposures and Their Relation to Temperature, Relative Humidity, and Air Exchange Rate
Open accessAbstract
Indoor microbial exposure has been related to adverse pulmonary health effects. Exposure assessment is not standardized, and various factors may affect the measured exposure. The aim of this study was to investigate the seasonal variation of selected microbial exposures and their associations with temperature, relative humidity, and air exchange rates in Danish homes. Airborne inhalable dust was sampled in five Danish homes throughout the four seasons of 1 year (indoors, n = 127; outdoors, n = 37). Measurements included culturable fungi and bacteria, endotoxin, N -acetyl-beta- d -glucosaminidase, total inflammatory potential, particles (0.75 to 15 μm), temperature, relative humidity, and air exchange rates. Significant seasonal variation was found for all indoor microbial exposures, excluding endotoxin. Indoor fungi peaked in summer (median, 235 CFU/m 3 ) and were lowest in winter (median, 26 CFU/m 3 ). Indoor bacteria peaked in spring (median, 2,165 CFU/m 3 ) and were lowest in summer (median, 240 CFU/m 3 ). Concentrations of fungi were predominately higher outdoors than indoors, whereas bacteria, endotoxin, and inhalable dust concentrations were highest indoors. Bacteria and endotoxin correlated with the mass of inhalable dust and number of particles. Temperature and air exchange rates were positively associated with fungi and N -acetyl-beta- d -glucosaminidase and negatively with bacteria and the total inflammatory potential. Although temperature, relative humidity, and air exchange rates were significantly associated with several indoor microbial exposures, they could not fully explain the observed seasonal variations when tested in a mixed statistical model. In conclusion, the season significantly affects indoor microbial exposures, which are influenced by temperature, relative humidity, and air exchange rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of Average Concentration in the Presence of Nondetectable Values
Hornung, R. W., & Reed, L. D. (1990) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1990.10389587 · Cited by 3,495
Bioaerosol Health Effects and Exposure Assessment: Progress and Prospects
(2003) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meg032 · Cited by 1,232
The link between fungi and severe asthma: A summary of the evidence
Denning, D. W., O'Driscoll, B. R., Hogaboam, C. M., Bowyer, P., & Niven, R. M. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00074705 · Cited by 824
The effect of environmental parameters on the survival of airborne infectious agents
Tang, J. W. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0227.focus · Cited by 631
Severity of asthma is related to endotoxin in house dust.
Michel, O., Kips, J., Duchateau, J., Vertongen, F., Robert, L., Collet, H., Pauwels, R., & Sergysels, R. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970348 · Cited by 576
Indirect health effects of relative humidity in indoor environments.
Arundel, A. V., Sterling, E. M., Biggin, J. H., & Sterling, T. D. (1986) · Environmental Health Perspectives · doi:10.1289/ehp.8665351 · Cited by 525
House Dust Endotoxin and Wheeze in the First Year of Life
PARK, J.-H., GOLD, D. R., SPIEGELMAN, D. L., BURGE, H. A., & MILTON, D. K. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.2.2002088 · Cited by 362
Effects of damp and mould in the home on respiratory health: a review of the literature
Peat, J. K., Dickerson, J., & Li, J. (1998) · Allergy · doi:10.1111/j.1398-9995.1998.tb03859.x · Cited by 351
Diversity and seasonal dynamics of bacterial community in indoor environment
Rintala, H., Pitkaranta, M., Toivola, M., Paulin, L., & Nevalainen, A. (2008) · BMC Microbiology · doi:10.1186/1471-2180-8-56 · Cited by 291
Collection of airborne micro‐organisms on Nuclepore filters, estimation and analysis—CAMNEA method
Palmgren, U., Ström, G., Blomquist, G., & Malmberg, P. (1986) · Journal of Applied Bacteriology · doi:10.1111/j.1365-2672.1986.tb04303.x · Cited by 259
Health Risk Assessment of Fungi in Home Environments
Verhoeff, A. P., & Burge, H. A. (1997) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)63214-0 · Cited by 254 · cited 1×
“Indoor microbial exposure has been related to adverse pulmonary health effects, headache, and allergy (6, 40, 45, 57).”
BackgroundKurup, V. P., Shen, H.-D., & Banerjee, B. (2000) · Microbes and Infection · doi:10.1016/s1286-4579(00)01264-8 · Cited by 253
The relation between fungal propagules in indoor air and home characteristics
Ren, P., Jankun, T. M., Belanger, K., Bracken, M. B., & Leaderer, B. P. (2001) · Allergy · doi:10.1034/j.1398-9995.2001.056005419.x · Cited by 223
Fungi and fungal products in some Canadian houses
Miller, J. D., Laflamme, A. M., Sobol, Y., Lafontaine, P., & Greenhalgh, R. (1988) · International Biodeterioration · doi:10.1016/0265-3036(88)90053-x · Cited by 201
The occupant as a source of house dust bacteria
Täubel, M., Rintala, H., Pitkäranta, M., Paulin, L., Laitinen, S., Pekkanen, J., Hyvärinen, A., & Nevalainen, A. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.07.045 · Cited by 197
Significance of air humidity and air velocity for fungal spore release into the air
Pasanen, A.-L., Pasanen, P., Jantunen, M. J., & Kalliokoski, P. (1991) · Atmospheric Environment. Part A. General Topics · doi:10.1016/0960-1686(91)90316-y · Cited by 191 · cited 1×
“In fact, the relative humidity has been shown to have profound effects on spore and particle release from fungal structures with which surfaces are infested (26, 39).”
BackgroundHealth Effects of Indoor Fungal Bioaerosol Exposure
Fung, F., & Hughson, W. G. (2003) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220301451 · Cited by 181
Predictors of airborne endotoxin in the home.
Park, J. H., Spiegelman, D. L., Gold, D. R., Burge, H. A., & Milton, D. K. (2001) · Environmental Health Perspectives · doi:10.1289/ehp.01109859 · Cited by 177
Summer Peaks in the Incidences of Gram-Negative Bacterial Infection Among Hospitalized Patients
Perencevich, E. N., McGregor, J. C., Shardell, M., Furuno, J. P., Harris, A. D., Morris, J. G., Fisman, D. N., & Johnson, J. A. (2008) · Infection Control & Hospital Epidemiology · doi:10.1086/592698 · Cited by 175
Quantification of airborne moulds in the homes of children with and without wheeze.
Strachan, D. P., Flannigan, B., McCabe, E. M., & McGarry, F. (1990) · Thorax · doi:10.1136/thx.45.5.382 · Cited by 173
Møller, J., Miller, M., & Kjøller, A. (1999) · Soil Biology and Biochemistry · doi:10.1016/s0038-0717(98)00138-2 · Cited by 173
Tischer, C., Chen, C.-M., & Heinrich, J. (2011) · European Respiratory Journal · doi:10.1183/09031936.00184010 · Cited by 167
Lee, T., Grinshpun, S. A., Martuzevičius, D., Adhikari, A., Crawford, C. M., Luo, J., & Reponen, T. A. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00396.x · Cited by 159
Reponen, T. A., Vesper, S. J., Levin, L. S., Johansson, E., Ryan, P., Burkle, J. W., Grinshpun, S. A., Zheng, S., Bernstein, D. I., Lockey, J. E., et al. (2011) · Annals of Allergy Asthma & Immunology · doi:10.1016/j.anai.2011.04.018 · Cited by 151
Comparison of sampling methods for the assessment of indoor microbial exposure
Frankel, M., Timm, M., Hansen, E. W., & Madsen, A. M. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00770.x · Cited by 148
Self-citationHargreaves, M. H., Parappukkaran, S., Morawska, L., Loveday, J., He, C., & Gilbert, D. (2003) · The Science of The Total Environment · doi:10.1016/s0048-9697(03)00169-4 · Cited by 146
The indoor air quality in Finnish homes with mold problems
Nevalainen, A., Pasanen, A.-L., Niininen, M., Reponen, T., Kalliokoski, P., & Jantunen, M. J. (1991) · Environment International · doi:10.1016/0160-4120(91)90015-i · Cited by 126
Immunobiology of Fungal Allergens
Kurup, V. P., Shen, H.-D., & Vijay, H. M. (2002) · International Archives of Allergy and Immunology · doi:10.1159/000066780 · Cited by 115
Normal Range Criteria for Indoor Air Bacteria and Fungal Spores in a Subarctic Climate
Reponen, T. A., Nevalainen, A. I., Jantunen, M. J., Pellikka, M., & Kalliokoski, P. (1992) · Indoor Air · doi:10.1111/j.1600-0668.1992.03-21.x · Cited by 114
Temporal and Spatial Variation of Fungal Concentrations in Indoor Air
Hyvärinen, A., Vahteristo, M., Meklin, T., Jantunen, M. J., Nevalainen, A. I., & Moschandreas, D. J. (2001) · Aerosol Science and Technology · doi:10.1080/02786820117763 · Cited by 113
Visually observed mold and moldy odor versus quantitatively measured microbial exposure in homes
Reponen, T. A., Singh, U. P., Schaffer, C., Vesper, S. J., Johansson, E., Adhikari, A., Grinshpun, S. A., Indugula, R., Ryan, P., Levin, L. S., et al. (2010) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2010.07.090 · Cited by 108
Temporal associations between daily counts of fungal spores and asthma exacerbations
Atkinson, R. W., Strachan, D. P., Anderson, H. R., Hajat, S., & Emberlin, J. C. (2006) · Occupational and Environmental Medicine · doi:10.1136/oem.2005.024448 · Cited by 106
Airborne endotoxin in different background environments and seasons.
Madsen, A. M. (2006) · PubMed · Cited by 99
Self-citationWhat are the roles of chitinases in the growing fungus?
Gooday, G. W., Zhu, W.-Y., & O'Donnell, R. W. (1992) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.1992.tb14067.x · Cited by 98
Characterizing Mold Problem Buildings - Concentrations And Flora Of Viable Fungi
Hyvarinen, A., Reponen, T., Husman, T., Ruuskanen, J., & Nevalainen, A. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00017.x · Cited by 95 · cited 1×
“However, other studies have in fact found higher levels of airborne fungi in buildings with moisture/fungal problems than in reference buildings (12, 18, 19).”
BackgroundMonitoring of Fungi and Bacteria in the Indoor Air of Primary Schools in Edirne City, Turkey
Aydoğdu, H., Asan, A., Otkun, M. T., & Türe, M. (2005) · Indoor and Built Environment · doi:10.1177/1420326x05057539 · Cited by 91
Assessment of indoor air in Austrian apartments with and without visible mold growth
Haas, D., Habib, J., Galler, H., Buzina, W., Schlacher, R., Marth, E., & Reinthaler, F. F. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.07.062 · Cited by 89
What are the roles of chitinases in the growing fungus?
Gooday, G. W., Zhu, W.-Y., & O'Donnell, R. W. (1992) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.1992.tb05730.x · Cited by 82
Fungal exposure in homes of patients with sarcoidosis - an environmental exposure study
Terčelj, M., Salobir, B., Harlander, M., & Rylander, R. (2011) · Environmental Health · doi:10.1186/1476-069x-10-8 · Cited by 81
Airborne bacteria and fungal spores in the indoor environment. A case study in Singapore
Goh, I., Obbard, J. P., Viswanathan, S., & Huang, Y. (2000) · Acta Biotechnologica · doi:10.1002/abio.370200111 · Cited by 64
Airborne Fungal and Bacterial Components in PM1 Dust from Biofuel Plants
Madsen, A. M., Schlünssen, V., Olsen, T. T., Sigsgaard, T., & Avci, H. (2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep045 · Cited by 55
Self-citationMadsen, A. M. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.07879-11 · Cited by 50
Self-citationTime and Space Uniformity of Indoor Bacteria Concentrations in Chicago Area Residences
Moschandreas, D. J., Pagilla, K. R., & Storino, L. V. (2003) · Aerosol Science and Technology · doi:10.1080/02786820300935 · Cited by 48
Assessment of the Total Inflammatory Potential of Bioaerosols by Using a Granulocyte Assay
Timm, M., Madsen, A. M., Hansen, J. V., Moesby, L., & Hansen, E. W. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.00928-09 · Cited by 48
Self-citationGarrett, M., Hooper, B. M., Cole, F. M., & Hooper, M. A. (1997) · Aerobiologia · doi:10.1007/bf02694428 · Cited by 47
Assessment and modeling of indoor fungal and bacterial bioaerosol concentrations
Green, C. F., Scarpino, P. V., & Gibbs, S. G. (2003) · Aerobiologia · doi:10.1023/b:aero.0000006531.35387.bd · Cited by 42
Spatiotemporal distribution of airborne mould spores in apartments
Herbarth, O., Schlink, U., Müller, A., & Richter, M. (2003) · Mycological Research · doi:10.1017/s0953756203008566 · Cited by 39
de Rochemonteix-Galve, B., Marchat-Amoruso, B., Dayer, J., et al. (1991) · Infection and Immunity · doi:10.1128/iai.59.10.3646-3650.1991 · Cited by 33
Timm, M., Hansen, E. W., Moesby, L., & Christensen, J. D. (2005) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2005.10.006 · Cited by 28
Self-citationMadsen, A. M., & Nielsen, S. H. (2010) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2010.03.001 · Cited by 26
Self-citationHaverinen‐Shaughnessy, U., Toivola, M., Alm, S., Putus, T., & Nevalainen, A. I. (2006) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500494 · Cited by 23
Allermann, L., Wilkins, C. K., & Madsen, A. M. (2006) · Toxicology in Vitro · doi:10.1016/j.tiv.2006.06.004 · Cited by 19
Self-citationThe Danish Centre for Indoor Air and Health in Dwellings – CISBO.
Sigsgaard, T., Clausen, G., Gunnarsen, L., Loft, S. H., Riddervold, I. S., & Wolkoff, P. (2011) · VBN Forskningsportal (Aalborg Universitet) · Cited by 3
Cited by
Indoor fungal diversity and asthma: A meta-analysis and systematic review of risk factors
Sharpe, R. A., Bearman, N., Thornton, C. R., Husk, K., & Osborne, N. J. (2015) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2014.07.002 · Cited by 314
Metadata
- Authors
- Frankel, M., Bekö, G., Timm, M., Gustavsen, S., Hansen, E. W., & Madsen, A. M.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2012-12
- Volume
- 78
- Issue
- 23
- Pages
- 8289-8297
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2074439370
- Cited by
- 287
- References
- 53
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.