Evaluation of a Disinfectant Wipe Intervention on Fomite-to-Finger Microbial Transfer
Open accessThe DOI matches its Crossref record; 64 of the 65 references it cites were found in a registry or an index.
Abstract
Inanimate surfaces, or fomites, can serve as routes of transmission of enteric and respiratory pathogens. No previous studies have evaluated the impact of surface disinfection on the level of pathogen transfer from fomites to fingers. Thus, the present study investigated the change in microbial transfer from contaminated fomites to fingers following disinfecting wipe use. Escherichia coli (10 8 to 10 9 CFU/ml), Staphylococcus aureus (10 9 CFU/ml), Bacillus thuringiensis spores (10 7 to 10 8 CFU/ml), and poliovirus 1 (10 8 PFU/ml) were seeded on ceramic tile, laminate, and granite in 10-μl drops and allowed to dry for 30 min at a relative humidity of 15 to 32%. The seeded fomites were treated with a disinfectant wipe and allowed to dry for an additional 10 min. Fomite-to-finger transfer trials were conducted to measure concentrations of transferred microorganisms on the fingers after the disinfectant wipe intervention. The mean log 10 reduction of the test microorganisms on fomites by the disinfectant wipe treatment varied from 1.9 to 5.0, depending on the microorganism and the fomite. Microbial transfer from disinfectant-wipe-treated fomites was lower (up to <0.1% on average) than from nontreated surfaces (up to 36.3% on average, reported in our previous study) for all types of microorganisms and fomites. This is the first study quantifying microbial transfer from contaminated fomites to fingers after the use of disinfectant wipe intervention. The data generated in the present study can be used in quantitative microbial risk assessment models to predict the effect of disinfectant wipes in reducing microbial exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Their study tested three different surfaces with four types of microorganisms, E. coli, S. aureus, B. thuringiensis, and PV-1. Their study has found that some microorganism may be more resistant to physical removal than others [84]”
From Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review (2019) · cites this paper as [84]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“which gives the clue that the adhesion of microorganism on wipes may be different depending on the type of material used.”
From Efficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review (2019) · cites this paper as [84]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antiseptics and Disinfectants: Activity, Action, and Resistance
McDonnell, G., & Russell, A. D. (1999) · Clinical Microbiology Reviews · doi:10.1128/cmr.12.1.147 · Cited by 4,780
How long do nosocomial pathogens persist on inanimate surfaces? A systematic review
Kramer, A., Schwebke, I., & Kampf, G. (2006) · BMC Infectious Diseases · doi:10.1186/1471-2334-6-130 · Cited by 2,504
Smith, M. C. M. (1991) · FEBS Letters · doi:10.1016/0014-5793(91)80059-c · Cited by 1,519
Molecular biological methods for Bacillus
Harwood, C. R., & Cutting, S. M. (1990) · Cited by 1,430
Ledell, K., Muto, C. A., Jarvis, W. R., & Farr, B. M. (2003) · Infection Control & Hospital Epidemiology · doi:10.1086/502924 · Cited by 1,192
Quantitative Microbial Risk Assessment
(2012) · SpringerReference · doi:10.1007/springerreference_226419 · Cited by 1,040
Self-citationQuantitative Microbial Risk Assessment
Haas, C. N., Rose, J. B., & Gerba, C. P. (2014) · Wiley eBooks · doi:10.1002/9781118910030 · Cited by 861
Self-citationCosgrove, S. E., Qi, Y., Kaye, K. S., Harbarth, S., Karchmer, A. W., & Carmeli, Y. (2005) · Infection Control & Hospital Epidemiology · doi:10.1086/502522 · Cited by 856
Survival of Enterococci and Staphylococci on Hospital Fabrics and Plastic
Neely, A. N., & Maley, M. P. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.2.724-726.2000 · Cited by 794
Weber, D. J., Rutala, W. A., Miller, M. B., Huslage, K., & Sickbert-Bennett, E. (2010) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.04.196 · Cited by 768
Cited by
Microbial Exchange via Fomites and Implications for Human Health
Stephens, B., Azimi, P., Thoemmes, M. S., Heidarinejad, M., Allen, J. G., & Gilbert, J. A. (2019) · Current Pollution Reports · doi:10.1007/s40726-019-00123-6 · Cited by 192
“Lopez et al. (2014) quantified fomite-to-finger microbial transfer of Escherichia coli, Staphylococcus aureus, Bacillus thuringiensis spores, and poliovirus 1 seeded on ceramic tile, laminate, and granite after treatment with a disinfectant wipe; microbial transfer was much lower on treated fomites…”
BackgroundEfficacy of disinfectant-impregnated wipes used for surface disinfection in hospitals: a review
Song, X., Vossebein, L., & Zille, A. (2019) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-019-0595-2 · Cited by 132
“The impact of pathogen transfer from fomites to fingers, using surface disinfecting wipes, has been evaluated by Lopez et al. (2014) in their research.”
Factors Shaping the Human Exposome in the Built Environment: Opportunities for Engineering Control
Dai, D., Prussin, A. J., Marr, L. C., Vikesland, P. J., Edwards, M. A., & Pruden, A. (2017) · Environmental Science & Technology · doi:10.1021/acs.est.7b01097 · Cited by 103
“Sci. U. S. A. 2014, 111 (2), 805− 10.”
Pathogen transfer and high variability in pathogen removal by detergent wipes
Ramm, L., Siani, H., Wesgate, R., & Maillard, J. (2015) · American Journal of Infection Control · doi:10.1016/j.ajic.2015.03.024 · Cited by 74
Contamination of healthcare workers' mobile phones by epidemic viruses
Pillet, S., Berthelot, P., Gagneux‐Brunon, A., Mory, O., Gay, C., Viallon, A., Lucht, F., Pozzetto, B., & Botelho-Nevers, É. (2015) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2015.12.008 · Cited by 55
“Published by Elsevier finger microbial transfer [30].”
Metadata
- Authors
- Lopez, G. U., Kitajima, M., Havas, A., Gerba, C. P., & Reynolds, K. A.
- Affiliations
- University of Arizona (US)
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2014-05-15
- Volume
- 80
- Issue
- 10
- Pages
- 3113-3118
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- PMC
- PMC4018905
- OpenAlex
- W2029418109
- Cited by
- 34
- References
- 65
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 4 · 2018: 3 · 2017: 1 · 2016: 1 · 2015: 7
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Applied and Environmental Microbiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Life Sciences › Agricultural and Biological Sciences › Food Science › Food Safety and Hygiene
- Keywords
- disinfectant wipes, surface disinfection, microbial transmission, Escherichia coli, Staphylococcus aureus, poliovirus type 1, ceramic tiles, laminates, granite, microbial risk assessment, hand contamination
- MeSH terms
- Bacteria, Disinfectants, Disinfection, Fingers, Humans, Viruses, Fomites
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.