The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Binding of metals to cell envelopes of Escherichia coli K-12
Open accessAbstract
As representative of gram-negative bacteria, the isolated and purified envelopes of an Escherichia coli K-12 strain were used to determine metal-binding capacity. The envelopes were suspended in 5 mM metal solutions for 10 min and 23 degrees C, separated and washed by centrifugation, and analyzed for metal by either atomic absorption or X-ray fluorescence spectroscopy. Of 32 metals tested, large amounts (> 0.9 mumol/mg [dry weight]) of Hf and Os, intermediate amounts (0.1 to 0.4 mumol/mg [dry weight]) of Pb, Zn, Zr, Fe III, Mn, Mo, Mg, Co, and Ce IV, and small amounts (< 0.1 mumol/mg [dry weight]) of Na, K, Rb, Ca, Sr, Cu, Sc, La, Pr, Sm, U, Fe II, Ru, Ni, Hg, Pt, Pd, Au, and In were detected Li and V were not bound to the envelopes. Electron microscopy of unstained, thin-sectioned material provided an electron-scattering profile for localizing the bound metal within the envelope. Energy-dispersive X-ray analysis of thin sections detected all metals in single envelope vesicles. These data suggest that most metal deposition occurred at the polar head group regions of the constituent membranes or along the peptidoglycan layer. No leaching of envelope components was detected by monitoring radioactive probes within the lipopolysaccharide and peptidoglycan layers during metal uptake experiments, sodium dodecyl sulfate-polyacrylamide gel electrophoresis of proteins from metal-loaded envelopes, or protein and carbohydrate determinations on the wash fluids. These results suggest that membrane integrity was not disturbed under these ionic conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colorimetric Method for Determination of Sugars and Related Substances
DuBois, M., Gilles, K. A., Hamilton, J. K., Rebers, P. A., & Smith, F. (1956) · Analytical Chemistry · doi:10.1021/ac60111a017 · Cited by 52,269
Cited by
A chemical equilibrium model for metal adsorption onto bacterial surfaces
Fein, J. B., Daughney, C. J., Yee, N., & Davis, T. A. (1997) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(97)00166-x · Cited by 709
Yee, N., Benning, L. G., Phoenix, V. R., & Ferris, F. G. (2004) · Environmental Science & Technology · doi:10.1021/es0346680 · Cited by 403
Biosorption of heavy metals by Saccharomyces cerevisiae
Volesky, B., & May-Phillips, H. A. (1995) · Applied Microbiology and Biotechnology · doi:10.1007/bf00171964 · Cited by 384
Bacteria-induced mineral precipitation: a mechanistic review
Hoffmann, T. D., Reeksting, B. J., & Gebhard, S. (2021) · Microbiology · doi:10.1099/mic.0.001049 · Cited by 206
Metadata
- Authors
- Beveridge, T. J., & Koval, S. F.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1981-08
- Volume
- 42
- Issue
- 2
- Pages
- 325-335
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2333736567
- Cited by
- 239
- References
- 1
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Binding of metals to cell envelopes of Escherichia coli K-12. https://app.cochat.ai/papers/10.1128/aem.42.2.325-335.1981
- The paper
- Beveridge, T. J., & Koval, S. F. (1981). Binding of metals to cell envelopes of Escherichia coli K-12. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.42.2.325-335.1981
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.