The DOI matches its Crossref record.
Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures
Open accessAbstract
Samples obtained from plumbing systems of hospitals, nonhospital institutions and homes were cultured for Legionella spp. by plating the samples directly on a selective medium. Swab samples were taken from the inner surfaces of faucet assemblies (aerators, spouts, and valve seats), showerheads, and shower pipes. Water and sediment were collected from the bottom of hot-water tanks. Legionella pneumophila serogroups 1, 5, and 6 were recovered from plumbing fixtures of the hospitals and nonhospital institutions and one of five homes. The legionellae (7 to 13,850 colony-forming units per ml) were also present in water and sediment from hot-water tanks maintained at 30 to 54 degrees C, but not in those maintained at 71 and 77 degrees C. Legionella micdadei was isolated from one tank. Thus legionellae are present in hot-water tanks which are maintained at warm temperatures or whose design results in warm temperatures at the bottom of the tanks. We hypothesize that hot-water tanks are a breeding site and a major source of L. pneumophila for the contamination of plumbing systems. The existence of these bacteria in the plumbing systems and tanks was not necessarily associated with disease. The extent of the hazard of this contamination needs to be delineated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rogers, J., Dowsett, A. B., Dennis, P. J., Lee, J. V., & Keevil, C. W. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.5.1585-1592.1994 · Cited by 285
Biofilm formation in the industry: A review
Mattila‐Sandholm, T., & Wirtanen, G. (1992) · Food Reviews International · doi:10.1080/87559129209540953 · Cited by 274
Rogers, J., Dowsett, A. B., Dennis, P. J., Lee, J. V., & Keevil, C. W. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.6.1842-1851.1994 · Cited by 256
Abdel-Nour, M., Duncan, C., Prashar, A., Rao, C., Ginevra, C., Jarraud, S., Low, D. E., Ensminger, A. W., Terebiznik, M. R., & Guyard, C. (2014) · Applied and Environmental Microbiology · doi:10.1128/aem.03254-13 · Cited by 50
Metadata
- Authors
- Wadowsky, R. M., Yee, R. B., Mezmar, L., Wing, E. J., & Dowling, J. N.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1982-05
- Volume
- 43
- Issue
- 5
- Pages
- 1104-1110
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1495033491
- Cited by
- 207
- References
- 0
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures. https://app.cochat.ai/papers/10.1128/aem.43.5.1104-1110.1982
- The paper
- Wadowsky, R. M., Yee, R. B., Mezmar, L., Wing, E. J., & Dowling, J. N. (1982). Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.43.5.1104-1110.1982
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.