R-plasmid transfer in a wastewater treatment plant
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Enteric bacteria have been examined for their ability to transfer antibiotic resistance in a wastewater treatment plant. Resistant Salmonella enteritidis, Proteus mirabilis, and Escherichia coli were isolated from clinical specimens and primary sewage effluent. Resistance to ampicillin, chloramphenicol, streptomycin, sulfadiazine, and tetracycline was demonstrated by spread plate and tube dilution techniques. Plasmid mediation of resistance was shown by ethidium bromide curing, agarose gel electrophoresis, and direct cell transfer. Each donor was mated with susceptible E. coli and Shigella sonnei. Mating pairs (and recipient controls) were suspended in unchlorinated primary effluent that had been filtered and autoclaved. Suspensions were added to membrane diffusion chambers which were then placed in the primary and secondary setting tanks of the wastewater treatment plant. Resistant recombinants were detected by replica plating nutrient agar master plates onto xylose lysine desoxycholate agar plates that contained per milliliter of medium 10 micrograms of ampicillin, 30 micrograms of chloramphenicol, 10 micrograms of streptomycin, 100 micrograms of sulfadiazine, or 30 micrograms of tetracycline. Mean transfer frequencies for laboratory matings were 2.1 X 10(-3). In situ matings for primary and secondary settling resulted in frequencies of 4.9 X 10(-5) and 7.5 X 10(-5), respectively. These values suggest that a significant level of resistance transfer occurs in wastewater treatment plants in the absence of antibiotics as selective agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid procedure for detection and isolation of large and small plasmids
Kado, C. I., & Liu, S. T. (1981) · Journal of Bacteriology · doi:10.1128/jb.145.3.1365-1373.1981 · Cited by 2,809 · cited 1×
“Plasmids were detected by a modification of the rapid lysis technique of Kado and Liu (23).”
MethodIdentification of Enterobacteriaceae.
Edwards, P. R., & Ewing, W. H. (1972) · Andalas University Repository (Andalas University) · Cited by 2,038
Macrina, F. L., Kopecko, D. J., Jones, K. R., Ayers, D. J., & McCowen, S. M. (1978) · Plasmid · doi:10.1016/0147-619x(78)90056-2 · Cited by 790 · cited 1×
“Relative mobility-molecular weight data points obtained from standard plasmid-containing bacteria (27, 28) were included with each plasmid detection experiment.”
MethodDatta, N. (1969) · BMJ · doi:10.1136/bmj.2.5654.407 · Cited by 131 · cited 1×
“, hospitals and hospital sewage effluent (9, 12, 17), commercial fisheries (40), and abattoirs (15, 31).”
BackgroundANDERSON, J. D., Richmond, M. H., & Gillespie, W. A. (1973) · Journal of Medical Microbiology · doi:10.1099/00222615-6-4-461 · Cited by 92 · cited 3×
“These studies have demonstrated that transfer does occur, and at relatively high rates, in wounds (21, 24) and in the gastrointestinal (3, 35), urinary, and respiratory tracts (13) of warmblooded animals, including humans.”
BackgroundFrequency of F116-mediated transduction of Pseudomonas aeruginosa in a freshwater environment
Morrison, W. D., Miller, R. V., & Sayler, G. S. (1978) · Applied and Environmental Microbiology · doi:10.1128/aem.36.5.724-730.1978 · Cited by 92 · cited 1×
“(29) demonstrated in situ transduction of streptomycin resistance to susceptible P.”
BackgroundAntibiotic Resistance and R Factors in Coliform Bacilli Isolated from Hospital and Domestic Sewage
Linton, K. B., Richmond, M. H., Bevan, R. E., & Gillespie, W. A. (1974) · Journal of Medical Microbiology · doi:10.1099/00222615-7-1-91 · Cited by 74 · cited 4×
“hospital wastewater may carry them (12, 17, 26, 37).”
BackgroundInfluentialAntibiotics in Animal Feeds and Animal Production
Jukes, T. H. (1972) · BioScience · doi:10.2307/1296312 · Cited by 62 · cited 1×
“Resistance transfer among gram-negative rods has posed a significant threat in human nosocomial infections (13, 24) and in other animal infections where antimicrobial prophylaxis has provided the selective pressure necessary to maintain R plasmids in the etiological agent(s) (22, 31).”
Background
Cited by
Rizzo, L., Manaia, C., Merlin, C., Schwartz, T., Dagot, C., Ploy, M. C., Michael, I., & Fatta-Kassinos, D. (2013) · Science of The Total Environment · doi:10.1016/j.scitotenv.2013.01.032 · Cited by 2,493
Colwell, R. R., Brayton, P. R., Grimes, D. J., Roszak, D. B., Huq, S. A., & Palmer, L. M. (1985) · Nature Biotechnology · doi:10.1038/nbt0985-817 · Cited by 731
Self-citationStudying plasmid horizontal transfer in situ: a critical review
Sørensen, S. J., Bailey, M., Hansen, L. H., Kroer, N., & Wuertz, S. (2005) · Nature Reviews Microbiology · doi:10.1038/nrmicro1232 · Cited by 725
Detection and fate of antibiotic resistant bacteria in wastewater treatment plants: A review
Bouki, C., Venieri, D., & Diamadopoulos, E. (2013) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2013.01.016 · Cited by 664
Antibiotic resistance of E. coli in sewage and sludge
Reinthaler, F. F., Posch, J., Feierl, G., Wüst, G., Haas, D., Ruckenbauer, G., Mascher, F., & Marth, E. (2003) · Water Research · doi:10.1016/s0043-1354(02)00569-9 · Cited by 556
Metadata
- Authors
- Mach, P. A., & Grimes, D. J.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1982-12
- Volume
- 44
- Issue
- 6
- Pages
- 1395-1403
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1758396856
- Cited by
- 159
- References
- 8
- FWCI
- 5.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.