Kinetics of Pseudomonas aeruginosa adhesion to 304 and 316-L stainless steel: role of cell surface hydrophobicity
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Fifteen different isolates of Pseudomonas aeruginosa were used to study the kinetics of adhesion to 304 and 316-L stainless steel. Stainless steel plates were incubated with approximately 1.5 X 10(7) CFU/ml in 0.01 M phosphate-buffered saline (pH 7.4). After the plates were rinsed with the buffer, the number of adhering bacteria was determined by a bioluminescence assay. Measurable adhesion, even to the electropolished surfaces, occurred within 30 s. Bacterial cell surface hydrophobicity, as determined by the bacterial adherence to hydrocarbons test and the contact angle measurement test, was the major parameter influencing the adhesion rate constant for the first 30 min of adhesion. A parabolic relationship between the CAM values and the logarithm of the adhesion rate constants (In k) was established. No correlation between either the salt aggregation or the improved salt aggregation values and the bacterial adhesion rate constants could be found. Since there was no significant correlation between the bacterial electrophoretic mobilities and the In k values, the bacterial cell surface charge seemed of minor importance in the process of adhesion of P. aeruginosa to 304 and 316-L stainless steel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bacterial Biofilms in Nature and Disease
Costerton, J. W., Cheng, K. J., Geesey, G. G., Ladd, T. I., Nickel, J. C., Dasgupta, M., & Marrie, T. J. (1987) · Annual Review of Microbiology · doi:10.1146/annurev.mi.41.100187.002251 · Cited by 3,145 · cited 2×
“The importance of avoiding bacterial adhesion to surgical implants (4, 11, 14, 15, 21), tap water distribution (13) and cooling (2, 4) systems, milk transfer pipelines (22), power plant condenser tubes (12), or water for injection distribution and storage systems (4, 8, 13, 36) is generally recognized.”
BackgroundMethodAdherence of bacteria to hydrocarbons: A simple method for measuring cell-surface hydrophobicity
Rosenberg, M. (1980) · FEMS Microbiology Letters · doi:10.1016/0378-1097(80)90106-8 · Cited by 2,331
The role of bacterial cell wall hydrophobicity in adhesion
van Loosdrecht, M. C., Lyklema, J., Norde, W., Schraa, G., & Zehnder, A. J. (1987) · Applied and Environmental Microbiology · doi:10.1128/aem.53.8.1893-1897.1987 · Cited by 959
van Loosdrecht, M. C., Lyklema, J., Norde, W., Schraa, G., & Zehnder, A. J. (1987) · Applied and Environmental Microbiology · doi:10.1128/aem.53.8.1898-1901.1987 · Cited by 725 · cited 1×
“The mobility was used as a measurement of the electrostatic state of the bacteria, without converting it into the theoretical Zeta potential (7, 16, 40).”
MethodNumbers of Receptor Sites from Scatchard Graphs: Facts and Fantasies
Klotz, I. M. (1982) · Science · doi:10.1126/science.6287580 · Cited by 676
Bacterial adherence to biomaterials and tissue. The significance of its role in clinical sepsis.
Gristina, A. G., & Costerton, J. W. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567020-00014 · Cited by 571 · cited 1×
“The importance of avoiding bacterial adhesion to surgical implants (4, 11, 14, 15, 21), tap water distribution (13) and cooling (2, 4) systems, milk transfer pipelines (22), power plant condenser tubes (12), or water for injection distribution and storage systems (4, 8, 13, 36) is generally recognized.”
BackgroundA new test based on ‘salting out’ to measure relative hydrophobicity of bacterial cells
Lindahl, M., Faris, A., Wadström, T., & Hjertén, S. (1981) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(81)90261-0 · Cited by 431
Hydrophobic Interactions: Role in Bacterial Adhesion
Rosenberg, M., & Kjelleberg, S. (1986) · Advances in Microbial Ecology · doi:10.1007/978-1-4757-0611-6_8 · Cited by 338
Methods for measuring hydrophobicity of microorganisms
Mozes, N., & Rouxhet, P. G. (1987) · Journal of Microbiological Methods · doi:10.1016/0167-7012(87)90058-3 · Cited by 223 · cited 1×
“The lowest concentration of ammonium sulfate giving visible aggregation was scored as the salt aggregation hydrophobicity test (SAT) value (17, 23, 24, 29, 33).”
MethodHydrophobicity as an Adhesion Mechanism of Benthic Cyanobacteria
Fattom, A., & Shilo, M. (1984) · Applied and Environmental Microbiology · doi:10.1128/aem.47.1.135-143.1984 · Cited by 197 · cited 1×
“This could be expected because electrostatic repulsions, which are pronounced in solutions with low ionic strength, reduce the adhesion of bacteria on the metal surface (9, 37).”
Background
Cited by
Biofilm formation in food industries: A food safety concern
Srey, S., Jahid, I. K., & Ha, S.-D. (2013) · Food Control · doi:10.1016/j.foodcont.2012.12.001 · Cited by 993
Beyond Risk: Bacterial Biofilms and Their Regulating Approaches
Muhammad, M. H., Idris, A. L., Fan, X., Guo, Y., Yu, Y., Jin, X., Qiu, J., Guan, X., & Huang, T. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.00928 · Cited by 860
Bacterial cell attachment, the beginning of a biofilm
Palmer, J., Flint, S., & Brooks, J. (2007) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-007-0234-4 · Cited by 755
Wilson, W. W., Wade, M. M., Holman, S. C., & Champlin, F. R. (2001) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(00)00224-4 · Cited by 626
Bacterial resistance to antibiotics: The role of biofilms
Hoyle, B. D., & Costerton, J. W. (1991) · Progress in Drug Research / Fortschritte der Arzneimittelforschung / Progrès des recherches pharmaceutiques · doi:10.1007/978-3-0348-7139-6_2 · Cited by 449
Micro- and Nanotopography Sensitive Bacterial Attachment Mechanisms: A Review
Cheng, Y., Feng, G., & Moraru, C. I. (2019) · Frontiers in Microbiology · doi:10.3389/fmicb.2019.00191 · Cited by 367
Microbial biofilms in the food processing industry—Should they be a concern?
Zottola, E. A., & Sasahara, K. C. (1994) · International Journal of Food Microbiology · doi:10.1016/0168-1605(94)90047-7 · Cited by 362
Whitehead, K. A., Colligon, J., & Verran, J. (2005) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2004.11.010 · Cited by 314
Flint, S. H., Brooks, J. D., & Bremer, P. J. (2000) · Journal of Food Engineering · doi:10.1016/s0260-8774(99)00157-0 · Cited by 298
Microbial Biofilms: Their Development and Significance for Medical Device—Related Infections
Habash, M., & Reid, G. (1999) · The Journal of Clinical Pharmacology · doi:10.1177/00912709922008506 · Cited by 287
Hydrodynamics and surface properties influence biofilm proliferation
Krsmanovic, M., Biswas, D., Ali, H., Kumar, A., Ghosh, R., & Dickerson, A. K. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102336 · Cited by 285
Faille, C., Jullien, C., Fontaine, F., Bellon-Fontaine, M.-N., Slomianny, C., & Benezech, T. (2002) · Canadian Journal of Microbiology · doi:10.1139/w02-063 · Cited by 256
Biofilms in dairy manufacturing plant‐description, current concerns and methods of control
Flint, S. H., Bremer, P. J., & Brooks, J. D. (1997) · Biofouling · doi:10.1080/08927019709378321 · Cited by 252
The Effect of Surface Topography on the Retention of Microorganisms
Whitehead, K. A., & Verran, J. (2006) · Food and Bioproducts Processing · doi:10.1205/fbp06035 · Cited by 244
Microbial attachment to food and food contact surfaces
Frank, J. F. (2001) · Advances in Food and Nutrition Research · doi:10.1016/s1043-4526(01)43008-7 · Cited by 179
Cai, L., Wu, D., Xia, J., Shi, H., & Kim, H. (2019) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.03.434 · Cited by 173
Metadata
- Authors
- Vanhaecke, E., Remon, J. P., Moors, M., Raes, F., De Rudder, D., & Van Peteghem, A.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1990-03
- Volume
- 56
- Issue
- 3
- Pages
- 788-795
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W1498600548
- Cited by
- 212
- References
- 27
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.