The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Heavy Metal Resistance of Biofilm and Planktonic Pseudomonas aeruginosa
Open accessAbstract
A study was undertaken to examine the effects of the heavy metals copper, lead, and zinc on biofilm and planktonic Pseudomonas aeruginosa . A rotating-disk biofilm reactor was used to generate biofilm and free-swimming cultures to test their relative levels of resistance to heavy metals. It was determined that biofilms were anywhere from 2 to 600 times more resistant to heavy metal stress than free-swimming cells. When planktonic cells at different stages of growth were examined, it was found that logarithmically growing cells were more resistant to copper and lead stress than stationary-phase cells. However, biofilms were observed to be more resistant to heavy metals than either stationary-phase or logarithmically growing planktonic cells. Microscopy was used to evaluate the effect of copper stress on a mature P. aeruginosa biofilm. The exterior of the biofilm was preferentially killed after exposure to elevated concentrations of copper, and the majority of living cells were near the substratum. A potential explanation for this is that the extracellular polymeric substances that encase a biofilm may be responsible for protecting cells from heavy metal stress by binding the heavy metals and retarding their diffusion within the biofilm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bacterial Biofilms: A Common Cause of Persistent Infections
Costerton, J. W., Stewart, P. S., & Greenberg, E. P. (1999) · Science · doi:10.1126/science.284.5418.1318 · Cited by 12,167
Anderl, J. N., Franklin, M. J., & Stewart, P. S. (2000) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.44.7.1818-1824.2000 · Cited by 958
Nucifora, G., Chu, L., Misra, T. K., & Silver, S. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.10.3544 · Cited by 359 · cited 1×
“Other types of efflux systems simply pump toxic metal ions out of the cell; these systems include the P-type ATPase cadA, which was first identified in Staphylococcus aureus and is found in other grampositive bacteria, that pumps out Cd2 and Zn2 by using a phospho-aspartate intermediate (30, 32 , 36).”
Background
Cited by
Physiological heterogeneity in biofilms
Stewart, P. S., & Franklin, M. J. (2008) · Nature Reviews Microbiology · doi:10.1038/nrmicro1838 · Cited by 2,327
Co-selection of antibiotic and metal resistance
Baker-Austin, C., Wright, M. S., Stepanauskas, R., & McArthur, J. V. (2006) · Trends in Microbiology · doi:10.1016/j.tim.2006.02.006 · Cited by 1,883
The role of bacterial biofilms in chronic infections
Bjarnsholt, T. (2013) · APMIS · doi:10.1111/apm.12099 · Cited by 1,080
Seiler, C., & Berendonk, T. U. (2012) · Frontiers in Microbiology · doi:10.3389/fmicb.2012.00399 · Cited by 1,018
Toxicity and Bioremediation of Heavy Metals Contaminated Ecosystem from Tannery Wastewater: A Review
Igiri, B. E., Okoduwa, S. I. R., Idoko, G. O., Akabuogu, E. P., Adeyi, A. O., & Ejiogu, I. K. (2018) · Journal of Toxicology · doi:10.1155/2018/2568038 · Cited by 933
Metadata
- Authors
- Teitzel, G. M., & Parsek, M. R.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2003-04
- Volume
- 69
- Issue
- 4
- Pages
- 2313-2320
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2013023789
- Cited by
- 693
- References
- 3
- FWCI
- 6.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heavy Metal Resistance of Biofilm and Planktonic Pseudomonas aeruginosa. https://app.cochat.ai/papers/10.1128/aem.69.4.2313-2320.2003
- The paper
- Teitzel, G. M., & Parsek, M. R. (2003). Heavy Metal Resistance of Biofilm and Planktonic Pseudomonas aeruginosa. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.69.4.2313-2320.2003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.