Detection of Airborne Stachybotrys chartarum Macrocyclic Trichothecene Mycotoxins on Particulates Smaller than Conidia
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Highly respirable particles (diameter, <1 μm) constitute the majority of particulate matter found in indoor air. It is hypothesized that these particles serve as carriers for toxic compounds, specifically the compounds produced by molds in water-damaged buildings. The presence of airborne Stachybotrys chartarum trichothecene mycotoxins on particles smaller than conidia (e.g., fungal fragments) was therefore investigated. Cellulose ceiling tiles with confluent Stachybotrys growth were placed in gas-drying containers through which filtered air was passed. Exiting particulates were collected by using a series of polycarbonate membrane filters with decreasing pore sizes. Scanning electron microscopy was employed to determine the presence of conidia on the filters. A competitive enzyme-linked immunosorbent assay (ELISA) specific for macrocyclic trichothecenes was used to analyze filter extracts. Cross-reactivity to various mycotoxins was examined to confirm the specificity. Statistically significant (P< 0.05) ELISA binding was observed primarily for macrocyclic trichothecenes at concentrations of 50 and 5 ng/ml and 500 pg/ml (58.4 to 83.5% inhibition). Of the remaining toxins tested, only verrucarol and diacetylverrucarol (nonmacrocyclic trichothecenes) demonstrated significant binding (18.2 and 51.7% inhibition, respectively) and then only at high concentrations. The results showed that extracts from conidium-free filters demonstrated statistically significant (P< 0.05) antibody binding that increased with sampling time (38.4 to 71.9% inhibition, representing a range of 0.5 to 4.0 ng/ml). High-performance liquid chromatography analysis suggested the presence of satratoxin H in conidium-free filter extracts. These data show that S. chartarum trichothecene mycotoxins can become airborne in association with intact conidia or smaller particles. These findings may have important implications for indoor air quality assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fungal Fragments as Indoor Air Biocontaminants
Górny, R. L., Reponen, T., Willeke, K., Schmechel, D., Robine, E., Boissier, M., & Grinshpun, S. A. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.7.3522-3531.2002 · Cited by 402 · cited 2×
“concluded, spore counts do not adequately represent the amount of fungal fragments that are present in the air at any given time (16).”
BackgroundCorrelation between the prevalence of certain fungi and sick building syndrome.
Cooley, J. D., Wong, W. C., Jumper, C. A., & Straus, D. C. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.9.579 · Cited by 329
Self-citation
Cited by
The health effects of nonindustrial indoor air pollution
Bernstein, J. A., Alexis, N., Bacchus, H., Bernstein, I. L., Fritz, P., Horner, E., Li, N., Mason, S., Nel, A., Oullette, J., et al. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.10.045 · Cited by 574
Molecular and Genetic Studies of Fusarium Trichothecene Biosynthesis: Pathways, Genes, and Evolution
KIMURA, M., TOKAI, T., TAKAHASHI-ANDO, N., OHSATO, S., & FUJIMURA, M. (2007) · Bioscience, Biotechnology, and Biochemistry · doi:10.1271/bbb.70183 · Cited by 409
Pitkäranta, M., Meklin, T., Hyvärinen, A., Paulin, L., Auvinen, P., Nevalainen, A., & Rintala, H. (2008) · Applied and Environmental Microbiology · doi:10.1128/aem.00692-07 · Cited by 216
“The latter benefit is especially valuable in indoor studies since the main exposure hazards relating to indoor microbial contamination are not dependent on viability (5, 26).”
BackgroundA two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.
Lindsley, W. G., Schmechel, D., & Chen, B. T. (2006) · Journal of Environmental Monitoring · doi:10.1039/b609083d · Cited by 117
Lee, S.-A., & Liao, C.-H. (2014) · Science of The Total Environment · doi:10.1016/j.scitotenv.2013.07.104 · Cited by 48
Metadata
- Authors
- Brasel, T. L., Douglas, D. R., Wilson, S. C., & Straus, D. C.
- Venue
- Applied and Environmental Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2005-01
- Volume
- 71
- Issue
- 1
- Pages
- 114-122
- ISSN
- 0099-2240 (ISSN-L)
- 1098-5336
- OpenAlex
- W2057675682
- Cited by
- 136
- References
- 2
- FWCI
- 9.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Airborne Stachybotrys chartarum Macrocyclic Trichothecene Mycotoxins on Particulates Smaller than Conidia. https://app.cochat.ai/papers/10.1128/aem.71.1.114-122.2005
- The paper
- Brasel, T. L., Douglas, D. R., Wilson, S. C., & Straus, D. C. (2005). Detection of Airborne Stachybotrys chartarum Macrocyclic Trichothecene Mycotoxins on Particulates Smaller than Conidia. Applied and Environmental Microbiology. https://doi.org/10.1128/aem.71.1.114-122.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.