A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Personal aerosol samplers are widely used to monitor human exposure to airborne materials. For bioaerosols, interest is growing in analyzing samples using molecular and immunological techniques. This paper presents a personal sampler that uses a two-stage cyclone to collect bioaerosols into disposable 1.5 ml Eppendorf-type microcentrifuge tubes. Samples can be processed in the tubes for polymerase chain reaction (PCR) or immunoassays, and the use of multiple stages fractionates aerosol particles by aerodynamic diameter. The sampler was tested using fluorescent microspheres and aerosolized fungal spores. The sampler had first and second stage cut-off diameters of 2.6 microm and 1.6 microm at 2 l min(-1)(geometric standard deviation, GSD = 1.45 and 1.75), and 1.8 microm and 1 microm at 3.5 l min(-1)(GSD = 1.42 and 1.55). The sampler aspiration efficiency was >or=98% at both flow rates for particles with aerodynamic diameters of 3.1 microm or less. For 6.2 microm particles, the aspiration efficiency was 89% at 2 l min(-1) and 96% at 3.5 l min(-1). At 3.5 l min(-1), the sampler collected 92% of aerosolized Aspergillus versicolor and Penicillium chrysogenum spores inside the two microcentrifuge tubes, with less than 0.4% of the spores collecting on the back-up filter. The design and techniques given here are suitable for personal bioaerosol sampling, and could also be adapted to design larger aerosol samplers for longer-term atmospheric and indoor air quality sampling.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Fungal Fragments as Indoor Air Biocontaminants
Górny, R. L., Reponen, T., Willeke, K., Schmechel, D., Robine, E., Boissier, M., & Grinshpun, S. A. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.7.3522-3531.2002 · Cited by 402
Self-citationHealth Risk Assessment of Fungi in Home Environments
Verhoeff, A. P., & Burge, H. A. (1997) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)63214-0 · Cited by 254
Airborne fungal fragments and allergenicity
Green, B. J., Tovey, E. R., Sercombe, J. K., Blachere, F. M., Beezhold, D. H., & Schmechel, D. (2006) · Medical Mycology · doi:10.1080/13693780600776308 · Cited by 214
Self-citationEffect of relative humidity on the aerodynamic diameter and respiratory deposition of fungal spores
Reponen, T., Willeke, K., Ulevicius, V., Reponen, A., & Grinshpun, S. A. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(96)00128-8 · Cited by 170
Fungal fragments and undocumented conidia function as new aeroallergen sources
Green, B. J., Sercombe, J. K., & Tovey, E. R. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.02.009 · Cited by 148
Brasel, T. L., Douglas, D. R., Wilson, S. C., & Straus, D. C. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.1.114-122.2005 · Cited by 136
Size distribution of bacterial and fungal bioaerosols in indoor air.
Górny, R. L., Dutkiewicz, J. K., & Krysińska‐Traczyk, E. (1999) · PubMed · Cited by 131
Aerodynamic characteristics and respiratory deposition of fungal fragments
Cho, S., Seo, S., Schmechel, D., Grinshpun, S. A., & Reponen, T. A. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.05.042 · Cited by 125
Self-citationEffect of Sampling Time on the Collection Efficiency of All-Glass Impingers
Lin, X., Willeke, K., Ulevicius, V., & Grinshpun, S. A. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012577 · Cited by 124
Characteristics of Airborne Actinomycete Spores
Reponen, T. A., Gazenko, S. V., Grinshpun, S. A., Willeke, K., & Cole, E. C. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.10.3807-3812.1998 · Cited by 86
Research works printed but not linked: 1
- Gorny, 1999, Ann. Agric. Environ. Med., 6, 105
Cited by
Measurement of Airborne Influenza Virus in a Hospital Emergency Department
Blachere, F. M., Lindsley, W. G., Pearce, T. A., Anderson, S. E., Fisher, M., Khakoo, R., Meade, B. J., Lander, O., Davis, S., Thewlis, R. E., et al. (2009) · Clinical Infectious Diseases · doi:10.1086/596478 · Cited by 342
“conjunction with a novel cyclone aerosol sampler [11].”
BackgroundMethodSelf-citationCollection, particle sizing and detection of airborne viruses
Pan, M., Lednicky, J. A., & Wu, C. ‐. (2019) · Journal of Applied Microbiology · doi:10.1111/jam.14278 · Cited by 261
“One sampler developed by the National Institute for Occupational Safety and Health (NIOSH) (Lindsley et al. 2006) is a multistage cyclone operating at a flowrate of 3 5 l min 1: the first stage is a 15-ml tube that collects aerosol particles >4 lm, the second is a 1 5 ml tube that collects particles between 1 and 4 lm…”
BackgroundInfluentialChamber Bioaerosol Study: Outdoor Air and Human Occupants as Sources of Indoor Airborne Microbes
Adams, R. I., Bhangar, S., Pasut, W., Arens, E. A., Taylor, J. W., Lindow, S. E., Nazaroff, W. W., & Bruns, T. D. (2015) · PLOS ONE · doi:10.1371/journal.pone.0128022 · Cited by 246
“The NIOSH cyclone sampler requires a lower flow rate vacuum pump, and successful use of this sampler in environmental settings has been based on longer sampling times [53] than we used here.”
MethodBioaerosol sampling: Classical approaches, advances, and perspectives
Mainelis, G. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1671950 · Cited by 229
“Researchers from the National Institute for Occupational Safety and Health (NIOSH) recently developed and successfully used in the field a microcentrifuge-tube cyclone (Lindsley, Schmechel, and Chen 2006; Macher, Chen, and Rao 2008; Su et al. 2012b).”
MethodComparison of Five Bacteriophages as Models for Viral Aerosol Studies
Turgeon, N., Toulouse, M.-J., Martel, B., Moineau, S., & Duchaine, C. (2014) · Applied and Environmental Microbiology · doi:10.1128/aem.00767-14 · Cited by 209
“The NIOSH two-stage bioaerosol sampler (29) has been previously shown to efficiently 383 sample phages (4-6, 30, 52) and influenza viruses (7).”
Method
Metadata
- Authors
- Lindsley, W. G., Schmechel, D., & Chen, B. T.
- Affiliations
- Centers for Disease Control and Prevention (US)
- Corresponding author
- Lindsley, William G.
- ORCID
- Lindsley, William G.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 8
- Issue
- 11
- Pages
- 1136
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W1977029565
- Cited by
- 117
- References
- 23
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 3 · 2023: 10 · 2022: 4 · 2021: 12 · 2020: 4 · 2019: 7 · 2018: 10 · 2017: 8 · 2016: 7 · 2015: 5 · 2014: 8 · 2013: 7 · 2012: 7
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Environmental Monitoring (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Computational Mechanics › Cyclone Separators and Fluid Dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Keywords
- microcentrifuge tubes, aerodynamic diameter, aspiration efficiency, fungal spores, Aspergillus versicolor, Penicillium chrysogenum, indoor air quality
- MeSH terms
- Aerosols, Bacteria, Centrifugation, Environmental Monitoring, Enzyme-Linked Immunosorbent Assay, Fungi, Humans, Particle Size, Spores, Fungal, Polymerase Chain Reaction, Occupational Exposure, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling. https://app.cochat.ai/papers/10.1039/b609083d
- The paper
- Lindsley, W. G., Schmechel, D., & Chen, B. T. (2006). A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling. Journal of Environmental Monitoring. https://doi.org/10.1039/b609083d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.