The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Multiplex Assay for Simultaneous Measurement of Antibodies to Multiple Plasmodium falciparum Antigens
Open accessAbstract
Antibodies to Plasmodium falciparum are classically measured using the enzyme-linked immunosorbent assay (ELISA). Although highly sensitive, this technique is labor-intensive when large numbers of samples must be screened against multiple antigens. The suspension array technology (SAT) might be an alterative to ELISA, as it allows measurement of antibodies against multiple antigens simultaneously with a small volume of sample. This study sought to adapt the new SAT multiplex system for measuring antibodies against nine malarial vaccine candidate antigens, including recombinant proteins from two variants of merozoite surface protein 1, two variants of apical merozoite antigen 1, erythrocyte binding antigen 175, merozoite surface protein 3, and peptides from the circumsporozoite protein, ring erythrocyte surface antigen, and liver-stage antigen 1. Various concentrations of the antigens were coupled to microspheres with different spectral addresses, and plasma samples from Cameroonian adults were screened by SAT in mono- and multiplex formats and by ELISA. Optimal amounts of protein required to perform the SAT assay were 10- to 100-fold less than that needed for ELISA. Excellent agreement was found between the single and multiplex formats ( R ≥ 0.96), even when two variants of the same antigen were used. The multiplex assay was rapid, reproducible, required less than 1 μl of plasma, and had a good correlation with ELISA. Thus, SAT provides an important new tool for studying the immune response to malaria rapidly and efficiently in large populations, even when the amount of plasma available is limited, e.g., in studies of neonates or finger-prick blood.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Multiplexed particle-based flow cytometric assays
Vignali, D. A. A. (2000) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00238-6 · Cited by 913 · cited 1×
“The use of a filter plate is believed to play a role in the increase in sensitivity (16).”
BackgroundBouharoun-Tayoun, H., Attanath, P., Sabchareon, A., Chongsuphajaisiddhi, T., & Druilhe, P. (1990) · The Journal of experimental medicine · doi:10.1084/jem.172.6.1633 · Cited by 544 · cited 1×
“Individuals living in areas where malaria is transmitted often become immune to the disease, with antibodies (Abs) being an important component of immunity (2).”
BackgroundSelf-citationSimultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
Carson, R. T., & Vignali, D. A. A. (1999) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00069-1 · Cited by 402 · cited 4×
“The SAT has a sensitivity equal to, or better than, ELISA for measuring cytokines (6) and has been reported to have a higher dynamic range (3).”
BackgroundInfluentialSuspension array technology: evolution of the flat-array paradigm
Nolan, J. P., & Sklar, L. A. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(01)01844-3 · Cited by 349 · cited 1×
“Flow cytometry was originally used to study whole cells, organelles, or nuclei (5), but it can also measure biological reactions on the surface of solid fluorospheres using suspension array technology (SAT) (10, 11, 15).”
BackgroundOpalka, D., Lachman, C. E., MacMullen, S. A., Jansen, K. U., Smith, J. F., Chirmule, N., & Esser, M. T. (2003) · Clinical and Vaccine Immunology · doi:10.1128/cdli.10.1.108-115.2003 · Cited by 276
Kellar, K. L., Kalwar, R. R., Dubois, K. A., Crouse, D., Chafin, W. D., & Kane, B.-E. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<27::aid-cyto1141>3.0.co;2-i · Cited by 194 · cited 1×
“The SAT has a sensitivity equal to, or better than, ELISA for measuring cytokines (6) and has been reported to have a higher dynamic range (3).”
BackgroundPickering, J. W., Martins, T. B., Greer, R. W., Schroder, M. C., Astill, M. E., Litwin, C. M., Hildreth, S. W., & Hill, H. R. (2002) · American Journal of Clinical Pathology · doi:10.1309/lmch-c4q2-vfl9-3t1a · Cited by 177 · cited 2×
“The technique has been used to measure Ab levels to protein Ags of several microbes (12, 14, 17) but not for more complex parasites.”
MethodResultProbability binning comparison: A metric for quantitating univariate distribution differences
Roederer, M., Treister, A., Moore, W., & Herzenberg, L. A. (2001) · Cytometry · doi:10.1002/1097-0320(20010901)45:1<79::aid-cyto1147>3.0.co;2-q · Cited by 173
Lal, G., Balmer, P., Stanford, E., Martin, S., Warrington, R., & Borrow, R. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.11.006 · Cited by 142 · cited 2×
“Multiplex assays have been developed for detecting Abs to combinations of viral and bacterial pathogens (7, 13) and to different bacterial serotypes (8, 9).”
MethodResultPickering, J. W., Martins, T. B., Schroder, M. C., & Hill, H. R. (2002) · Clinical and Vaccine Immunology · doi:10.1128/cdli.9.4.872-876.2002 · Cited by 131 · cited 5×
“The shorter incubation and, thus, shorter total assay time of the SAT assay has been described previously (13).”
BackgroundMethodResultInfluential
Cited by
Doolan, D. L., Dobaño, C., & Baird, J. K. (2009) · Clinical Microbiology Reviews · doi:10.1128/cmr.00025-08 · Cited by 1,301
“At between 4 and 10 months of age many infants are seronegative to specific malaria antigens (1, 254), but the kinetics of decay of maternal antibodies show interindividual variations which depend on the antigen and the epidemiological setting (119).”
BackgroundOsier, F. H. A., Fegan, G., Polley, S. D., Murungi, L., Verra, F., Tetteh, K. K. A., Lowe, B., Mwangi, T., Bull, P. C., Thomas, A. W., et al. (2008) · Infection and Immunity · doi:10.1128/iai.01585-07 · Cited by 387
“High-throughput assays employing suspension array technology (27) or microarrays (29, 64) now allow for simultaneous analysis of antibodies to multiple antigens using minimal amounts of sera.”
BackgroundRecent Progress in the Development of Diagnostic Tests for Malaria
Krampa, F. D., Aniweh, Y., Awandare, G. A., & Kanyong, P. (2017) · Diagnostics · doi:10.3390/diagnostics7030054 · Cited by 85
“An attempt to ease the laborious burden of screening large samples against multiple antigens by enzyme immunoassays (EIA) saw Fouda and colleagues [68] implement the suspension array technology (SAT), which employs a fluorescent labelled microsphere with diverse optical properties.”
BackgroundTutterrow, Y. L., Avril, M., Singh, K., Long, C. A., LEKE, R. J. I., Sama, G., Salanti, A., Smith, J. D., Leke, R. G. F., & Taylor, D. W. (2012) · Infection and Immunity · doi:10.1128/iai.00071-12 · Cited by 75
“formed at pH 7 overnight at 4°C as previously described (22), followed by”
MethodSelf-citationHigh Avidity Antibodies to Full-Length VAR2CSA Correlate with Absence of Placental Malaria
Tutterrow, Y. L., Salanti, A., Avril, M., Smith, J. D., Pagano, I., Ako, S. E., Fogako, J., Leke, R. G. F., & Taylor, D. W. (2012) · PLoS ONE · doi:10.1371/journal.pone.0040049 · Cited by 75
“) at pH 7 [40].”
Self-citationSteel, C., Golden, A., Kubofcik, J., LaRue, N., Santos, T. D. L., Domingo, G. J., & Nutman, T. B. (2013) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00252-13 · Cited by 67
“The Luminex suspension array technology assay has been described in detail elsewhere (15).”
MethodFernández-Becerra, C., Sanz, S., Brucet, M., Stanisic, D. I., Alves, F. P., Camargo, E. P., Alonso, P. L., Müeller, I., & Portillo, H. A. D. (2010) · Malaria Journal · doi:10.1186/1475-2875-9-29 · Cited by 65
“Recently, these methodologies have been reported to measure antibodies to multiple malaria vaccine candidate antigens [11], to measure simultaneously antibody recognition of twenty eight Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1) domains [12], and to develop a high throughput functional assay to stu…”
Metenou, S., Dembélé, B., Konaté, S., Dolo, H., Coulibaly, S. Y., Coulibaly, Y. I., Diallo, A. A., Soumaoro, L., Coulibaly, M. E., Sanogo, D., et al. (2009) · The Journal of Immunology · doi:10.4049/jimmunol.0900257 · Cited by 65
“The suspension array technology assay protocol used was modified from the technique published by Fouda and collaborators (35) and was performed using a BioPlex platform and BioPlex Manager, version 5 (Bio-Rad Laboratories).”
MethodAmbrosino, E., Dumoulin, C., Orlandi‐Pradines, E., Remoué, F., Touré-Baldé, A., Tall, A., Sarr, J. B., Poinsignon, A., Sokhna, C., Puget, K., et al. (2010) · Malaria Journal · doi:10.1186/1475-2875-9-317 · Cited by 65
“Moreover, they have been described to have similar or improved sensitivity relative to ELISA assays [13,14], and have proved useful as a tool for the detection of serum Abs directed against infectious pathogens [10,15,16].”
BackgroundMethodResultInfluentialSelf-citationCham, G. K. K., Kurtis, J. D., Lusingu, J., Theander, T. G., Jensen, A. T., & Turner, L. (2008) · Malaria Journal · doi:10.1186/1475-2875-7-108 · Cited by 60
“Fouda et al [7] reported a multiplex assay for measuring antibodies to nine P. falciparum malaria proteins.”
BackgroundInfluentialSerological markers to measure recent changes in malaria at population level in Cambodia
Kerkhof, K., Sluydts, V., Willen, L., Kim, S., Canier, L., Heng, S., Tsuboi, T., Sochantha, T., Sovannaroth, S., Ménard, D., et al. (2016) · Malaria Journal · doi:10.1186/s12936-016-1576-z · Cited by 58
Kerkhof, K., Canier, L., Kim, S., Heng, S., Sochantha, T., Sovannaroth, S., Vigan-Womas, I., Coosemans, M., Sluydts, V., Ménard, D., et al. (2015) · Malaria Journal · doi:10.1186/s12936-015-0868-z · Cited by 50
“Moreover, the results of previous studies [5, 15, 17] in which monoplex assays resulted in highly comparable ΔMFI values as multiplex assays were confirmed.”
BackgroundResultInfluentialDodoo, D., Atuguba, F., Bosomprah, S., Ansah, N. A., Ansah, P. B., Lamptey, H., Egyir, B., Oduro, A. R., Gyan, B. A., Hodgson, A., et al. (2011) · Malaria Journal · doi:10.1186/1475-2875-10-108 · Cited by 45
“, Austin, TX) was programmed to read a minimum of 100 microspheres per bead region, and results were expressed as mean fluorescent intensity (MFI), which is directly proportional to antibody concentration[14].”
MethodInfluentialPerraut, R., Richard, V., Marie-Louise, V., Trape, J., Guillotte-Blisnick, M., Tall, A., Touré, A., Sokhna, C., Vigan-Womas, I., & Mercereau‐Puijalon, O. (2014) · Malaria Journal · doi:10.1186/1475-2875-13-410 · Cited by 39
“Multiplex assays in the format of protein microarrays [10-12,35,36], Luminex system [13-16,37] allow high throughput, flexible investigation of multiple antibody specificities in a single assay.”
MethodResultKoffi, D., Touré, A. O., Marie-Louise, V., Vigan-Womas, I., Béourou, S., Brou, S., Ehouman, M.-F., Gnamien, L., Richard, V., Djaman, J. A., et al. (2015) · Malaria Journal · doi:10.1186/s12936-015-1043-2 · Cited by 37
“This pilot study involved an array of antigens previously investigated [11, 13] with the aim to provide immunology-related study in populations from this country.”
BackgroundRui, E., Fernández-Becerra, C., Takeo, S., Sanz, S., Lacerda, M., Tsuboi, T., & Portillo, H. A. D. (2011) · Malaria Journal · doi:10.1186/1475-2875-10-192 · Cited by 36
“Suspension array technologies with high-throughput capacity to simultaneously analyse several proteins with minimal amount of immune sera have also been developed and used in analysis of multiple malaria vaccine candidates as well as in developing functional assays [17-20].”
MethodHuaman, M. C., Martin, L. B., Malkin, E. M., Narum, D. L., Miller, L. H., Mahanty, S., & Long, C. A. (2008) · The Journal of Immunology · doi:10.4049/jimmunol.180.3.1451 · Cited by 35
“Serum samples from volunteers vaccinated with MSP142–FVO/Alhydrogel (n 3 volunteers providing samples) and MSP142–3D7/Alhydrogel (n 5 volunteers providing samples), which produced the highest levels of specific IgG Abs against homologous Ag (400 or more ELISA units on day 194) (21), were selected for IgE evaluation ag…”
MethodSelf-citationOndigo, B. N., Park, G. S., Gose, S. O., Ho, B. M., Ochola, L., Ayodo, G. O., Ofulla, A. V. O., & John, C. C. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-427 · Cited by 34
“falciparum or Plasmodium vivax antigens in malaria endemic populations [11,12].”
BackgroundSarr, J. B., Orlandi‐Pradines, E., Fortin, S., Sow, C., Cornélie, S., Rogerie, F., Guindo, S., Konaté, L., Fusaï, T., Riveau, G. J., et al. (2011) · Parasites & Vectors · doi:10.1186/1756-3305-4-212 · Cited by 34
“An immunoassay that measures Ab to multiple Ags simultaneously would be highly advantageous [13].”
BackgroundDent, A. E., Malhotra, I. J., Wang, X., Babineau, D. C., Yeo, K. T., Anderson, T., Kimmel, R., Angov, E., Lanar, D. E., Narum, D. L., et al. (2015) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00452-15 · Cited by 31
van den Hoogen, L. L., Présumé, J., Romilus, I., Mondélus, G., Elismé, T., Sepúlveda, N., Stresman, G. H., Druetz, T., Ashton, R. A., Joseph, V., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-57876-0 · Cited by 31
Itell, H. L., McGuire, E., Muresan, P., Cunningham, C. K., McFarland, E. J., Borkowsky, W., Permar, S. R., & Fouda, G. G. (2018) · Vaccine · doi:10.1016/j.vaccine.2018.07.048 · Cited by 31
“Antigens were coupled to carboxylated MicroPlex microspheres (Bio-Rad Laboratories, Hercules, CA) using a previously described protocol [20].”
MethodSelf-citationBabakhanyan, A., Fang, R., Wey, A. R., Salanti, A., Sama, G., Efundem, C., LEKE, R. J. I., Chen, J. J., Leke, R. G. F., & Taylor, D. W. (2015) · Malaria Journal · doi:10.1186/s12936-015-1023-6 · Cited by 28
“microspheres The method used for coupling was reported previously [31].”
BackgroundMethodSelf-citationDevelopment of a Multiplex Bead-Based Assay for Detection of Hepatitis C Virus
Fonseca, B. D. P. F. E., Marques, C. F. S., Nascimento, L. D., de Mello, M. B., Silva, L. B. R., Rubim, N. M., Foti, L., da Silva, E. D., Ferreira, A., & Krieger, M. A. (2011) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00265-10 · Cited by 27
“This system is an open platform that allows the detection of several molecules, with applications for the screening of serum antibodies against a plethora of infectious agents (8, 9, 14, 15) and also for vaccine trials (22).”
BackgroundBabakhanyan, A., Leke, R. G. F., Salanti, A., Bobbili, N., Gwanmesia, P., Leke, R. J. I., Quakyi, I. A., Chen, J. J., & Taylor, D. W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0088173 · Cited by 26
“Measuring IgG and IgM using the MAP assay MAP assay was performed as previously described [23,24,30].”
MethodSelf-citationSander, A. F., Salanti, A., Lavstsen, T., Nielsen, M. A., Theander, T. G., Leke, R. G. F., Lo, Y. Y., Bobbili, N., Arnot, D. E., & Taylor, D. W. (2011) · The Journal of Infectious Diseases · doi:10.1093/infdis/jir168 · Cited by 25
“Antibodies to VAR2CSA Antibody levels were determined using a multiplex assay as described elsewhere [13].”
Self-citationVidal, M., Aguilar, R., Campo, J. J., & Dobaño, C. (2018) · Journal of Immunological Methods · doi:10.1016/j.jim.2018.01.009 · Cited by 27
Kusi, K. A., Manu, E. A., Gwira, T. M., Baafour, E. K., Dickson, E. K., Amponsah, J. A., Remarque, E. J., Faber, B. W., Kocken, C. H. M., Dodoo, D., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0185303 · Cited by 24
Macalinao, M. L., Fornace, K., Reyes, R. A., Hall, T., Bareng, A. P. N., Adams, J. H., Huon, C., Chitnis, C. E., Luchavez, J., Tetteh, K. K. A., et al. (2023) · The Lancet Regional Health - Western Pacific · doi:10.1016/j.lanwpc.2023.100792 · Cited by 22
“,18 – 22 These approaches allow the inclusion of multiple targets that can represent diversity in the parasite and variation in individual immune response.”
Multiplexed VeraCode bead-based serological immunoassay for colorectal cancer
Ostendorff, H. P., Awad, A. S., Braunschweiger, K. I., Liu, Z., Wan, Z., Rothschild, K. J., & Lim, M. J. (2013) · Journal of Immunological Methods · doi:10.1016/j.jim.2013.09.013 · Cited by 21
“, 2003) and parasitic antigens (Fouda et al., 2006), as well as pneumococcal (Schlottmann et al.”
BackgroundBabakhanyan, A., Ekali, G. L., Dent, A. E., Kazura, J. W., Nguasong, J. T., Fodjo, B. A. Y., Yuosembom, E. K., Esemu, L. F., Taylor, D. W., & Leke, R. G. F. (2016) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofw092 · Cited by 20
“, San Jose, CA) [36]; and tetanus toxin C-fragment ([TTc] from J.”
MethodInfluentialSelf-citationFodjo, B. A. Y., Atemnkeng, N., Esemu, L. F., Yuosembom, E. K., Quakyi, I. A., Tchinda, V. H. M., Smith, J. D., Salanti, A., Bigoga, J. D., Taylor, D. W., et al. (2016) · Malaria Journal · doi:10.1186/s12936-016-1585-y · Cited by 19
Self-citationTiming of the human prenatal antibody response to Plasmodium falciparum antigens
Tassi Yunga, S., Kayatani, A. K., Fogako, J., Leke, R. J. I., Leke, R. G. F., & Taylor, D. W. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184571 · Cited by 18
Self-citationHIV envelope antigen valency on peptide nanofibers modulates antibody magnitude and binding breadth
Fries, C. N., Chen, J., Dennis, M. L., Votaw, N. L., Eudailey, J., Watts, B. E., Hainline, K. M., Cain, D. W., Barfield, R., Chan, C. C. W., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-93702-x · Cited by 18
Self-citationDevelopment and evaluation of a multiplex screening assay for Plasmodium falciparum exposure
Jepsen, M. P. G., Röser, D., Christiansen, M., Larsen, S. O., Cavanagh, D. R., Dhanasarnsombut, K., Bygbjerg, I. C., Dodoo, D., Remarque, E. J., Dziegiel, M. H., et al. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2012.07.009 · Cited by 18
Fang, R., Wey, A. R., Bobbili, N., Leke, R. F. G., Taylor, D. W., & Chen, J. J. (2017) · Malaria Journal · doi:10.1186/s12936-017-1933-6 · Cited by 17
Self-citationUbillos, I., Campo, J. J., Jiménez, A., & Dobaño, C. (2018) · Malaria Journal · doi:10.1186/s12936-018-2365-7 · Cited by 17
“Repeatability has traditionally been assessed by estimating the CV or relative SD [3, 16, 47, 48].”
BackgroundDuVall, A. S., Fairley, J. K., Sutherland, L. J., Bustinduy, A. L., Mungai, P., Muchiri, E. M., Malhotra, I. J., Kitron, U. D., & King, C. H. (2014) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.13-0292 · Cited by 17
Multiplexed immunoassay to assess Shigella-specific antibody responses
Kaminski, R. W., Clarkson, K. A., Kordis, A. A., & Oaks, E. V. (2013) · Journal of Immunological Methods · doi:10.1016/j.jim.2013.04.002 · Cited by 17
Rising report of Plasmodium vivax in sub-Saharan Africa: Implications for malaria elimination agenda
Oboh, M. A., Oyebola, K. M., Idowu, E. T., Badiane, A. S., Otubanjo, O. A., & Ndiaye, D. (2020) · Scientific African · doi:10.1016/j.sciaf.2020.e00596 · Cited by 16
Agbana, H. B., Rogier, E. W., Lô, A. C., Abukari, Z., Jones, S., Gyan, B. A., Aidoo, M., & Amoah, L. E. (2022) · Malaria Journal · doi:10.1186/s12936-022-04078-w · Cited by 16
Lloyd, Y. M., Fang, R., Bobbili, N., Vanda, K., Ngati, E. P., Sanchez‐Quintero, M. J., Salanti, A., Chen, J. J., Leke, R. G. F., & Taylor, D. W. (2018) · Infection and Immunity · doi:10.1128/iai.00166-18 · Cited by 13
“Characteristics of the antigens (37, 38), methods for coupling and optimization of the Luminex-based multianalyte platform assay (12, 39), and reproducibility (38) have been reported previously.”
MethodSelf-citationTaylor, D. W., Bobbili, N., Kayatani, A. K. K., Yunga, S. T., Kidima, W. B., & Leke, R. F. G. (2020) · Malaria Journal · doi:10.1186/s12936-020-03243-3 · Cited by 13
Self-citationVarela, M. L., Mbengué, B., Basse, A., Loucoubar, C., Vigan-Womas, I., Dièye, A., Touré, A., & Perraut, R. (2018) · Malaria Journal · doi:10.1186/s12936-018-2465-4 · Cited by 13
Dent, A. E., Moormann, A. M., Yohn, C. T., Kimmel, R., Sumba, P. O., VULULE, J. M., Long, C. A., Narum, D. L., Crabb, B. S., Kazura, J. W., et al. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-287 · Cited by 12
“Carboxylated microspheres (Luminex, Austin, TX, USA) were coupled to malaria antigens using the manufacturer’s protocol and as described [27,28].”
MethodSelf-citationKwan, J., Seitz, A. E., Fried, M., Lee, K.-L., Metenou, S., Morrison, R., Kabyemela, E., Nutman, T. B., Prevots, D. R., & Duffy, P. E. (2018) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0006345 · Cited by 12
Multiplexing detection of IgG against Plasmodium falciparum pregnancy-specific antigens
Fonseca, A. M., Quintó, L., Jiménez, A., González, R., Bardají, A., Maculuve, S. A., Dobaño, C., Rupérez, M., Valá, A., Aponte, J. J., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0181150 · Cited by 15
“As a result of the growing demand for rapid, precise and cost-effective techniques for the detection of antibodies, multiplex-bead array assays have been developed to provide measures using large numbers of antigens [25,26].”
BackgroundPerraut, R., & Varela, M.-L. (2015) · Journal of Immunological Techniques in Infectious Diseases · doi:10.4172/2329-9541.1000134 · Cited by 12
“falciparum antigens checked for concordance with ELISA monoplex [13,15].”
BackgroundMethodResultInfluentialWood, B. A., Carver, S., Troyer, R. M., Elder, J. H., & VandeWoude, S. (2013) · Journal of Immunological Methods · doi:10.1016/j.jim.2013.08.001 · Cited by 11
“, 2008)), Plasmodium falciparum (Fouda et al., 2006), Toxoplasma gondii (Kaul et al.”
BackgroundKayatani, A. K. K., Leke, R. G. F., Leke, R. I. J., Fogako, J., & Taylor, D. W. (2022) · Scientific Reports · doi:10.1038/s41598-022-21908-8 · Cited by 10
Self-citationBabakhanyan, A., Tutterrow, Y. L., Bobbili, N., Salanti, A., Wey, A. R., Fogako, J., LEKE, R. J. I., Leke, R. G. F., & Taylor, D. W. (2015) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.15-0521 · Cited by 10
“Each antigen was covalently coupled at optimal concentrations (1 μg for DBL domains, 3 μg for FV2) to 1 million SeroMap beads (Luminex, Austin, TX), as previously described.(27,33) Antigencoupled beads were pooled and tested to confirm that competition among the antigens did not occur.”
MethodSelf-citationThe use of multiplexing technology in the immunodiagnosis of infectious agents
Engin, D. (2019) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2018.1563551 · Cited by 11
“SAT uses symmetrical microspheres, which are combined after coupling to different antigens to produce MIAs, thereby the rapid screening of multiple malaria antigens is provided using a small volume of plasma.([30,31]) As another option, the use of a magnetic bead-based immunoassay (MBA) is advantageous compared to ELI…”
MethodEvaluation of llama anti-botulinum toxin Heavy chain Antibody
Anderson, G. P., Vera, Y. A. O., Hayhurst, A., Czarnecki, J., Dabbs, J., Vo, B. T., & Goldman, E. R. (2008) · The Botulinum J · doi:10.1504/tbj.2008.018953 · Cited by 10
“The Luminex platform has become a common platform for a variety of immunoassay applications (Yan et al., 2005; Fouda et al., 2006; Anderson et al., 2007).”
BackgroundA versatile, high through-put, bead-based phagocytosis assay for Plasmodium falciparum
Lloyd, Y. M., Ngati, E. P., Salanti, A., Leke, R. G. F., & Taylor, D. W. (2017) · Scientific Reports · doi:10.1038/s41598-017-13900-4 · Cited by 10
Self-citationYao, M., Sun, X., Gao, Y., Cheng, Z., Deng, W., Zhang, J., & Wang, H. (2016) · Infectious Diseases of Poverty · doi:10.1186/s40249-016-0194-x · Cited by 9
“infection [17], antibody responses to single antigens are circumscribed and inadequate as biomarkers for indicat-”
BackgroundAlvarado, R., van den Hoogen, L. L., Iriemenam, N. C., Akinmulero, O. O., Thomas, A. N., Tamunonengiyeofori, I., Erasogie, E., Chimaoge, A. C., Dawurung, A. B., Esiekpe, M. K., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-92723-w · Cited by 8
Ndiabamoh, C. M.-C., Ekali, G. L., Esemu, L. F., Lloyd, Y. M., Djontu, J. C., Mbacham, W. F., Bigoga, J. D., Taylor, D. W., & Leke, R. G. F. (2020) · PLoS ONE · doi:10.1371/journal.pone.0242012 · Cited by 7
Self-citationSiriwardhana, C., Fang, R., Salanti, A., Leke, R. G. F., Bobbili, N., Taylor, D. W., & Chen, J. J. (2017) · Malaria Journal · doi:10.1186/s12936-017-2041-3 · Cited by 7
“to microspheres The method for coupling recombinant proteins to SeroMAP microspheres has been described previously [16, 27].”
Self-citationDjontu, J. C., Lloyd, Y. M., Megnekou, R., Seumko’o, R. M. N., Salanti, A., Taylor, D. W., & Leke, R. G. F. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237671 · Cited by 6
“IPTp-SP has been implemented in Cameroon since 2004 and the coverage rate of IPTp-SP (at least one dose of SP during pregnancy) is currently estimated at 30% in the rural areas and 70% in the urban areas [25].”
BackgroundMethodSelf-citationChauhan, R., Gupta, N., Tiwari, A. K., Raina, V., & Nandi, S. P. (2020) · Immunological Investigations · doi:10.1080/08820139.2020.1854782 · Cited by 5
“Previous studies (Carson and Vignali 1999; Fouda et al. 2006) demonstrated the bead-based assay as a sensitive technique for the measurement of antibodies in the patient’s sera.”
MethodElviri, L., & Mattarozzi, M. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-384862-8.00016-9 · Cited by 5
Shift in epitope dominance of IgM and IgG responses to Plasmodium falciparum MSP1 block 4
Chang, S. P., Kayatani, A. K. K., TERRIENTES, Z. I., Herrera, S. V., Leke, R. G. F., & Taylor, D. W. (2010) · Malaria Journal · doi:10.1186/1475-2875-9-14 · Cited by 4
“A Luminex® bead-based multiplex serological assay was used to measure antibodies to the four block 4 peptides and to blocks 16-17 [9].”
MethodSelf-citationYunga, S. T., Bobbili, N., Lloyd, Y. M., Antallan, J., Matsunaga, M., Quakyi, I. A., Leke, R. F. G., & Taylor, D. W. (2021) · Infection and Immunity · doi:10.1128/iai.00522-20 · Cited by 4
“The recombinant antigens used in the study have been described previously (34, 35) and included MSP1-42 (3D7 and FVO), MSP2 (3D7 and FcR3), MSP3, EBA-175, and AMA1.”
MethodSelf-citationA novel duplex ELISA method for quantitation of plasma proteins in areas of brain edema
Loftspring, M. C., Clark, J. F., & Wagner, K. R. (2007) · Brain Research · doi:10.1016/j.brainres.2007.06.019 · Cited by 4
Kayatani, A. K. K., Bobbili, N., Megnekou, R., Matsunaga, M., Leke, R. F. G., & Taylor, D. W. (2023) · Placenta · doi:10.1016/j.placenta.2023.07.011 · Cited by 3
Self-citationAnalysis of Antibody Reactivity to Malaria Antigens by Microsphere-Based Multiplex Immunoassay
Walker, I. S., Chung, A. W., Damelang, T., & Rogerson, S. J. (2022) · Methods in molecular biology · doi:10.1007/978-1-0716-2189-9_23 · Cited by 3
Taylor, D. W., Bobbili, N., Khadka, V. S., Quakyi, I. A., & Leke, R. G. F. (2017) · Malaria Journal · doi:10.1186/s12936-017-1704-4 · Cited by 3
“The multiplex analyte platform for antibodies Malarial antigens were coupled to SeroMap microspheres as previously described [14].”
Self-citationAlves, J. R. S., de Araújo, F. F., Pires, C. V., Teixeira‐Carvalho, A., Lima, B. A. S., Torres-Martínez, L. M., Ntumngia, F. B., Adams, J. H., Kano, F. S., & de Carvalho, L. H. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.704653 · Cited by 2
“Taken together, using a minimum number of plasma samples, this multiplex detection corroborates previous reports showing the feasibility of multiplex detection of malaria antibody responses against different allelic variants of the same antigen (50, 51).”
ResultMomoh, E. O., Ghag, S. K., White, J. C., Mudeppa, D. G., & Rathod, P. K. (2023) · Vaccines · doi:10.3390/vaccines12010001 · Cited by 2
“Previous multiplexed bead-based methods have detected malaria patient antibody responses [30–38].”
MethodXueLi, D., Xu, J., Hou, M., Yu, R., Ge, J.-J., Zhu, H., & Wu, H. (2009) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2009.07.020 · Cited by 2
“This is consistent with the results of other studies (Fouda et al., 2006) and indicates that multiplex MIA is not less sensitive than the monoplex assay and that there is no crossreactivity among the 3 proteins used.”
BackgroundResultLloyd, Y. M., Bobbili, N., Salanti, A., Gwanmesia, P., Fogako, J., Leke, R. G. F., & Taylor, D. W. (2023) · Medical Research Archives · doi:10.18103/mra.v11i8.4187 · Cited by 1
Self-citationBioprobe-conjugate polymeric micro/nanoparticles as detection tools for infectious diseases
Chansaenpak, K., Jangpatarapongsa, K., & Polpanich, D. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821506-7.00022-3 · Cited by 1
Malaria and polypeptides of Plasmodium falciparum at the infected erythrocyte surface
Palmkvist, M. (2016) · Figshare · Cited by 1
Title: Contrasting Patterns of Serologic and Functional Antibody Dynamics to Plasmodium
Dent, A. E., Wang, X., Babineau, D. C., Yeo, K. T., Kimmel, R., Lanar, D. E., Narum, D. L., Richards, J. S., Beeson, J. G., Crabb, B. S., et al. (2015)
Toledo, T. S., Cunha, P. M., Lima‐Junior, J. D. C., Campos, M. P., Renzetti, A. R. S., Figueiredo, F. B., Morgado, F. N., Porrozzi, R., Conceição‐Silva, F., Santiago, M. D. A., et al. (2025) · Antibodies · doi:10.3390/antib14040103
“However, as its weight approaches the suggested limit for effective coupling, we evaluated the VQ34 peptide not only directly coupled to the beads but also conjugated to BSA protein [27,28] or a peptide tag composed of beta-alanine-lysine (x4)-cysteine [29].”
InfluentialTaylor, D. W., Bobbili, N., Kayatani, A., Yunga, S. T., Kidima, W., & Leke, R. F. G. (2020) · Figshare · doi:10.6084/m9.figshare.12233813
Self-citationTaylor, D. W., Bobbili, N., Kayatani, A., Yunga, S. T., Kidima, W., & Leke, R. F. G. (2020) · Figshare · doi:10.6084/m9.figshare.12233804
Self-citationTaylor, D. W., Bobbili, N., Kayatani, A., Yunga, S. T., Kidima, W., & Leke, R. F. G. (2020) · Figshare · doi:10.6084/m9.figshare.12233822
Self-citationAgbana, H. B., Rogier, E. W., Lo, A., Abukari, Z., Jones, S., Gyan, B., Aidoo, M., & Amoah, L. E. (2022) · Figshare · doi:10.6084/m9.figshare.19204512
In Utero B Cell Responses to Plasmodium falciparum and Risk of Malaria during the First Year of Life
Yunga, S. T. (2017) · ScholarSpace (University of Hawaii at Manoa)
Mechanisms associated to hemoglobinopathic protection against plasmodium falciparum malaria
Tétard, M. (2018) · theses.fr (ABES) · doi:10.70675/bc0c5748zbdcbz432dz86bezfad593e42735
Metadata
- Authors
- Fouda, G. G., Leke, R. F. G., Long, C., Druilhe, P., Zhou, A., Taylor, D. W., & Johnson, A. H.
- Affiliations
- Georgetown University (US)
- Université de Yaoundé I (CM)
- National Institutes of Health (US)
- Institut Pasteur (FR)
- AZ DataClinic, Inc., Rockville, Maryland 20850
- Corresponding author
- Taylor, Diane Wallace
- Venue
- Clinical and Vaccine Immunology
- Publisher
- American Society for Microbiology
- Published
- 2006-12
- Volume
- 13
- Issue
- 12
- Pages
- 1307-1313
- ISSN
- 1556-679X (ISSN-L)
- 1556-6811
- PMC
- PMC1694450
- OpenAlex
- W2091354877
- Cited by
- 80
- References
- 17
- Citations by year
- 2025: 1 · 2023: 4 · 2022: 4 · 2021: 5 · 2020: 9 · 2019: 1 · 2018: 7 · 2017: 8 · 2016: 6 · 2015: 6 · 2014: 3 · 2013: 4 · 2012: 6
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical and Vaccine Immunology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Public Health Agency
- National Institute of Allergy and Infectious Diseases (R21AI053798, U01 AI43888, U01AI043888, R21AI53798)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Phytochemical compounds biological activities
- Keywords
- Plasmodium falciparum, malaria antibodies, multiplex immunoassay, merozoite surface protein 1, MSP3, circumsporozoite protein, antibody measurement, microsphere immunoassay, ELISA comparison, finger prick blood, neonatal immune response
- MeSH terms
- Adult, Amino Acid Sequence, Animals, Antibodies, Protozoan, Antigens, Protozoan, Enzyme-Linked Immunosorbent Assay, Humans, Microspheres, Molecular Sequence Data, Plasmodium falciparum, Recombinant Proteins, Sensitivity and Specificity, Reproducibility of Results, Protozoan Proteins, Malaria, Falciparum, Malaria Vaccines
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.