Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 191

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Performance of Purified Antigens for Serodiagnosis of Pulmonary Tuberculosis: a Meta-Analysis

Open access
Steingart, Karen R., Dendukuri, Nandini, Henry, Megan, Schiller, Ian, Nahid, Payam, Hopewell, Philip C., Ramsay, Andrew, Pai, Madhukar, Laal, Suman · 2009 · Clinical and Vaccine Immunology

Abstract

Serological antibody detection tests for tuberculosis may offer the potential to improve diagnosis. Recent meta-analyses have shown that commercially available tests have variable accuracies and a limited clinical role. We reviewed the immunodiagnostic potential of antigens evaluated in research laboratories (in-house) for the serodiagnosis of pulmonary tuberculosis and conducted a meta-analysis to evaluate the performance of comparable antigens. Selection criteria included the participation of at least 25 pulmonary tuberculosis patients and the use of purified antigens. Studies evaluating 38 kDa, MPT51, malate synthase, culture filtrate protein 10, TbF6, antigen 85B, α-crystallin, 2,3-diacyltrehalose, 2,3,6-triacyltrehalose, 2,3,6,6′-tetraacyltrehalose 2′-sulfate, cord factor, and TbF6 plus DPEP (multiple antigen) were included in the meta-analysis. The results demonstrated that (i) in sputum smear-positive patients, sensitivities significantly ≥50% were provided for recombinant malate synthase (73%; 95% confidence interval [CI], 58 to 85) and TbF6 plus DPEP (75%; 95% CI, 50 to 91); (ii) protein antigens achieved high specificities; (iii) among the lipid antigens, cord factor had the best overall performance (sensitivity, 69% [95% CI, 28 to 94]; specificity, 91% [95% CI, 78 to 97]); (iv) compared with the sensitivities achieved with single antigens (median sensitivity, 53%; range, 2% to 100%), multiple antigens yielded higher sensitivities (median sensitivity, 76%; range, 16% to 96%); (v) in human immunodeficiency virus (HIV)-infected patients who are sputum smear positive, antibodies to several single and multiple antigens were detected; and (vi) data on seroreactivity to antigens in sputum smear-negative or pediatric patients were insufficient. Potential candidate antigens for an antibody detection test for pulmonary tuberculosis in HIV-infected and -uninfected patients have been identified, although no antigen achieves sufficient sensitivity to replace sputum smear microscopy. Combinations of select antigens provide higher sensitivities than single antigens. The use of a case-control design with healthy controls for the majority of studies was a limitation of the review. Efforts are needed to improve the methodological quality of tuberculosis diagnostic studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/cvi.00355-08

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 191

Metadata

Authors
Steingart, K. R., Dendukuri, N., Henry, M., Schiller, I., Nahid, P., Hopewell, P. C., Ramsay, A., Pai, M., & Laal, S.
Venue
Clinical and Vaccine Immunology
Published
2009-02
Volume
16
Issue
2
Pages
260-276
ISSN
  • 1556-679X (ISSN-L)
  • 1556-6811
OpenAlex
W2165020270
Cited by
191
References
4
FWCI
1.75
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of Purified Antigens for Serodiagnosis of Pulmonary Tuberculosis: a Meta-Analysis. https://app.cochat.ai/papers/10.1128/cvi.00355-08
The paper
Steingart, K. R., Dendukuri, N., Henry, M., Schiller, I., Nahid, P., Hopewell, P. C., Ramsay, A., Pai, M., & Laal, S. (2009). Performance of Purified Antigens for Serodiagnosis of Pulmonary Tuberculosis: a Meta-Analysis. Clinical and Vaccine Immunology. https://doi.org/10.1128/cvi.00355-08

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.