The DOI matches its Crossref record.
Real-Time Imaging of Fluorescent Flagellar Filaments
Open accessAbstract
Bacteria swim by rotating flagellar filaments that are several micrometers long, but only about 20 nm in diameter. The filaments can exist in different polymorphic forms, having distinct values of curvature and twist. Rotation rates are on the order of 100 Hz. In the past, the motion of individual filaments has been visualized by dark-field or differential-interference-contrast microscopy, methods hampered by intense scattering from the cell body or shallow depth of field, respectively. We have found a simple procedure for fluorescently labeling cells and filaments that allows recording their motion in real time with an inexpensive video camera and an ordinary fluorescence microscope with mercury-arc or strobed laser illumination. We report our initial findings with cells of Escherichia coli . Tumbles (events that enable swimming cells to alter course) are remarkably varied. Not every filament on a cell needs to change its direction of rotation: different filaments can change directions at different times, and a tumble can result from the change in direction of only one. Polymorphic transformations tend to occur in the sequence normal, semicoiled, curly 1, with changes in the direction of movement of the cell body correlated with transformations to the semicoiled form.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A field guide to bacterial swarming motility
Kearns, D. B. (2010) · Nature Reviews Microbiology · doi:10.1038/nrmicro2405 · Cited by 1,483
The Rotary Motor of Bacterial Flagella
Berg, H. C. (2003) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.72.121801.161737 · Cited by 1,457
Self-citationComplete atomic model of the bacterial flagellar filament by electron cryomicroscopy
Yonekura, K., Maki-Yonekura, S., & Namba, K. (2003) · Nature · doi:10.1038/nature01830 · Cited by 746
Escherichia coli swim on the right-hand side
DiLuzio, W. R., Turner, L., Mayer, M., Garstecki, P., Weibel, D. B., Berg, H. C., & Whitesides, G. M. (2005) · Nature · doi:10.1038/nature03660 · Cited by 527
Self-citationSowa, Y., & Berry, R. M. (2008) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583508004691 · Cited by 435
Metadata
- Authors
- Turner, L., Ryu, W. S., & Berg, H. C.
- Venue
- Journal of Bacteriology
- Publisher
- American Society for Microbiology
- Published
- 2000-05-15
- Volume
- 182
- Issue
- 10
- Pages
- 2793-2801
- ISSN
- 0021-9193 (ISSN-L)
- 1098-5530
- OpenAlex
- W2114668427
- Cited by
- 720
- References
- 0
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Imaging of Fluorescent Flagellar Filaments. https://app.cochat.ai/papers/10.1128/jb.182.10.2793-2801.2000
- The paper
- Turner, L., Ryu, W. S., & Berg, H. C. (2000). Real-Time Imaging of Fluorescent Flagellar Filaments. Journal of Bacteriology. https://doi.org/10.1128/jb.182.10.2793-2801.2000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.