Evaluation of the BD Phoenix Automated Microbiology System for Identification and Antimicrobial Susceptibility Testing of Enterobacteriaceae
Open accessThe DOI matches its Crossref record.
Abstract
We evaluated the accuracy of the BD Phoenix system for the identification (ID) and antimicrobial susceptibility testing (AST) of 251 isolates of the family Enterobacteriaceae representing 31 species. Organisms were inoculated onto the Phoenix panel according to the manufacturer's instructions. The results from conventional biochemical tests were used for the reference method for ID. Agar dilution, performed according to the CLSI guidelines, was the reference AST method. Essential and categorical agreements were determined. The overall levels of agreement for the genus- and species-level identifications were 95.6% and 94.4%, respectively. Fourteen isolates were incorrectly identified by the Phoenix system; 10 of these were incorrectly identified to the species level. Three of these were Enterobacter ( Pantoea ) species and four of these were Shigella spp. misidentified as Escherichia coli . For AST results, the essential and categorical agreements were 98.7% and 97.9%, respectively. The very major error, major error, and minor error rates were 0.38%, 0.33%, and 1.8%, respectively. Six isolates (three E. coli isolates and three Klebsiella isolates) were extended-spectrum β-lactamase producers. All six were flagged by the Phoenix system expert rules. The Phoenix system compares favorably to traditional methods for ID and AST of Enterobacteriaceae .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Developing an in silico minimum inhibitory concentration panel test for Klebsiella pneumoniae
Nguyen, M., Brettin, T., Long, S. W., Musser, J. M., Olsen, R. J., Olson, R., Shukla, M., Stevens, R. L., Xia, F., Yoo, H., et al. (2018) · Scientific Reports · doi:10.1038/s41598-017-18972-w · Cited by 191
Blood culture-free ultra-rapid antimicrobial susceptibility testing
Kim, T. H., Kang, J., Jang, H., Joo, H., Lee, G. Y., Kim, H., Cho, U., Bang, H., Jang, J., Han, S., et al. (2024) · Nature · doi:10.1038/s41586-024-07725-1 · Cited by 90
Kateete, D. P., Nakanjako, R., Namugenyi, J., Erume, J., Joloba, M. L., & Najjuka, C. F. (2016) · SpringerPlus · doi:10.1186/s40064-016-2986-7 · Cited by 84
May, A. K., Brady, J. S., Romano-Keeler, J., Drake, W. P., Norris, P. R., Jenkins, J. M., Isaacs, R. J., & Boczko, E. M. (2015) · Chest · doi:10.1378/chest.14-1687 · Cited by 40
Pitruzzello, G., Johnson, S., & Krauss, T. F. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.115056 · Cited by 20
Metadata
- Authors
- Carroll, K. C., Glanz, B. D., Borek, A. P., Burger, C., Bhally, H. S., Henciak, S., & Flayhart, D.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2006-10
- Volume
- 44
- Issue
- 10
- Pages
- 3506-3509
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2096413472
- Cited by
- 88
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the BD Phoenix Automated Microbiology System for Identification and Antimicrobial Susceptibility Testing of Enterobacteriaceae. https://app.cochat.ai/papers/10.1128/jcm.00994-06
- The paper
- Carroll, K. C., Glanz, B. D., Borek, A. P., Burger, C., Bhally, H. S., Henciak, S., & Flayhart, D. (2006). Evaluation of the BD Phoenix Automated Microbiology System for Identification and Antimicrobial Susceptibility Testing of Enterobacteriaceae. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00994-06
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.