Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial

Open access
Salimnia, Hossein, Fairfax, Marilynn R., Lephart, Paul R., Schreckenberger, Paul, DesJarlais, Sharon M., Johnson, J. Kristie, Robinson, Gwen, Carroll, Karen C., Greer, Amy, Morgan, Margie, Chan, Raymond, Loeffelholz, Michael, Valencia-Shelton, Frances, Jenkins, Stephen, Schuetz, Audrey N., Daly, Judy A., Barney, Trenda, Hemmert, Andrew, Kanack, Kristen J.·2016·Journal of Clinical Microbiology

Abstract

Sepsis is a major cause of morbidity, mortality, and increased medical expense. Rapid diagnosis improves outcomes and reduces costs. The FilmArray blood culture identification panel (BioFire Diagnostics LLC, Salt Lake City, UT), a highly multiplexed PCR assay, can identify 24 etiologic agents of sepsis (8 Gram-positive, 11 Gram-negative, and 5 yeast species) and three antimicrobial resistance genes ( mecA , vanA / B , and bla KPC ) from positive blood culture bottles. It provides results in about 1 h with 2 min for assay setup. We present the results of an eight-center trial comparing the sensitivity and specificity of the panel with those of the laboratories' standard phenotypic identification techniques, as well as with molecular methods used to distinguish Acinetobacter baumannii from other members of the A. calcoaceticus - A. baumannii complex and to detect antimicrobial resistance genes. Testing included 2,207 positive aerobic blood culture samples, 1,568 clinical and 639 seeded. Samples were tested fresh or were frozen for later testing within 8 h after the bottles were flagged as positive by an automated blood culture system. At least one organism was detected by the panel in 1,382 (88.1%) of the positive clinical specimens. The others contained primarily off-panel organisms. The panel reported multiple organisms in 81 (5.86%) positive clinical specimens. The unresolved blood culture identification sensitivity for all target detections exceeded 96%, except for Klebsiella oxytoca (92.2%), which achieved 98.3% sensitivity after resolution of an unavoidable phenotypic error. The sensitivity and specificity for vanA / B and bla KPC were 100%; those for mecA were 98.4 and 98.3%, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.01679-15

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 243

Metadata

Authors
Salimnia, H., Fairfax, M. R., Lephart, P. R., Schreckenberger, P., DesJarlais, S. M., Johnson, J. K., Robinson, G., Carroll, K. C., Greer, A., Morgan, M., Chan, R., Loeffelholz, M., Valencia-Shelton, F., Jenkins, S., Schuetz, A. N., Daly, J. A., Barney, T., Hemmert, A., & Kanack, K. J.
Venue
Journal of Clinical Microbiology
Published
2016-03
Volume
54
Issue
3
Pages
687-698
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2236656655
Cited by
243
References
2
FWCI
24.79
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial. https://app.cochat.ai/papers/10.1128/jcm.01679-15
The paper
Salimnia, H., Fairfax, M. R., Lephart, P. R., Schreckenberger, P., DesJarlais, S. M., Johnson, J. K., Robinson, G., Carroll, K. C., Greer, A., Morgan, M., Chan, R., Loeffelholz, M., Valencia-Shelton, F., Jenkins, S., Schuetz, A. N., Daly, J. A., Barney, T., Hemmert, A., & Kanack, K. J. (2016). Evaluation of the FilmArray Blood Culture Identification Panel: Results of a Multicenter Controlled Trial. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.01679-15

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.