The diagnosis of syphilis is challenging and often relies on serologic tests to detect treponemal or nontreponemal antibodies. Recently, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories proposed an update to the syphilis serology testing algorithm, in which serum samples are first tested using a treponema-specific test and positive samples are analyzed with a nontreponemal assay. The goal of this study was to compare the performance of seven treponemal assays (BioPlex 2200 syphilis IgG [Bio-Rad, Hercules, CA], fluorescent treponemal antibody [FTA] assay [Zeus Scientific, Raritan, NJ], Treponema pallidum particle agglutination [TP-PA; Fujirebio Diagnostics, Malvern, PA], Trep-Sure enzyme immunoassay [EIA; Phoenix Biotech, Oakville, Ontario, Canada], Trep-Chek EIA [Phoenix Biotech], Trep-ID EIA [Phoenix Biotech], and Treponema ViraBlot IgG [Viramed Biotech AG, Planegg, Germany]) using serum samples ( n = 303) submitted to our reference laboratory. In addition to testing with these 7 assays, all samples were tested by a rapid plasma reagin (RPR) assay and a treponemal IgM Western blot assay (Viramed ViraBlot). Compared to the FTA assay as the gold standard, the evaluated treponemal tests demonstrated comparable levels of performance, with percent agreement ranging from 95.4% (95% confidence interval, 92.3 to 97.3) for the Trep-Sure EIA to 98.4% (96.1 to 99.4) for the Trep-ID EIA. Compared to a “consensus of the test panel” (defined as at least 4 of 7 treponemal tests being in agreement), the percent agreement ranged from 95.7% (92.7 to 97.5) for Trep-Sure to 99.3% (97.5 to 99.9) for Trep-ID. These data may assist clinical laboratories that are considering implementing a treponemal test for screening or confirmatory purposes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.02555-10

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 104

Metadata

Authors
Binnicker, M. J., Jespersen, D. J., & Rollins, L. O.
Venue
Journal of Clinical Microbiology
Published
2011-04
Volume
49
Issue
4
Pages
1313-1317
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2113101607
Cited by
104
References
0
FWCI
5.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treponema-Specific Tests for Serodiagnosis of Syphilis: Comparative Evaluation of Seven Assays. https://app.cochat.ai/papers/10.1128/jcm.02555-10
The paper
Binnicker, M. J., Jespersen, D. J., & Rollins, L. O. (2011). Treponema-Specific Tests for Serodiagnosis of Syphilis: Comparative Evaluation of Seven Assays. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.02555-10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.