Cited by 40Cervical Cancer and HPV ResearchBiosensors and Analytical DetectionReproductive tract infections research

Validation of a Low-Cost Human Papillomavirus Genotyping Assay Based on PGMY PCR and Reverse Blotting Hybridization with Reusable Membranes

Open access
Estrade, C., Menoud, P.-A., Nardelli-Haefliger, D., Sahli, R.·2011·Journal of Clinical Microbiology

Abstract

The genotyping of human papillomaviruses (HPV) is essential for the surveillance of HPV vaccines. We describe and validate a low-cost PGMY-based PCR assay (PGMY-CHUV) for the genotyping of 31 HPV by reverse blotting hybridization (RBH). Genotype-specific detection limits were 50 to 500 genome equivalents per reaction. RBH was 100% specific and 98.61% sensitive using DNA sequencing as the gold standard (n= 1,024 samples). PGMY-CHUV was compared to the validated and commercially available linear array (Roche) on 200 samples. Both assays identified the same positive (n= 182) and negative samples (n= 18). Seventy-six percent of the positives were fully concordant after restricting the comparison to the 28 genotypes shared by both assays. At the genotypic level, agreement was 83% (285/344 genotype-sample combinations; κ of 0.987 for single infections and 0.853 for multiple infections). Fifty-seven of the 59 discordant cases were associated with multiple infections and with the weakest genotypes within each sample (P< 0.0001). PGMY-CHUV was significantly more sensitive for HPV56 (P= 0.0026) and could unambiguously identify HPV52 in mixed infections. PGMY-CHUV was reproducible on repeat testing (n= 275 samples; 392 genotype-sample combinations; κ of 0.933) involving different reagents lots and different technicians. Discordant results (n= 47) were significantly associated with the weakest genotypes in samples with multiple infections (P< 0.0001). Successful participation in proficiency testing also supported the robustness of this assay. The PGMY-CHUV reagent costs were estimated at $2.40 per sample using the least expensive yet proficient genotyping algorithm that also included quality control. This assay may be used in low-resource laboratories that have sufficient manpower and PCR expertise.

Integrity signals

Registry

Crossref · 10.1128/jcm.05039-11

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Estrade, C., Menoud, P.-A., Nardelli-Haefliger, D., & Sahli, R.
Affiliations
  • Centre Hospitalier Universitaire Vaudois (CH)
  • MCL Medical Laboratories, 3172 Niederwangen, Switzerland
  • WHO HPV LabNet Regional Reference Laboratory for Europe, Institute of Microbiology, Centre Hospitalier Universitaire Vaudois (CHUV), and University of Lausanne, 1011 Lausanne, Switzerland
Venue
Journal of Clinical Microbiology
Published
2011-10
Volume
49
Issue
10
Pages
3474-3481
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2117905925
Cited by
40
References
0
Citations by year
2024: 1 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 4 · 2017: 3 · 2015: 3 · 2014: 6 · 2013: 5 · 2012: 4
FWCI
3.86
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Microbiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • IRIS (submittedVersion)
  • SERVAL (Université de Lausanne) (submittedVersion)
Funders
  • Bill and Melinda Gates Foundation
  • Université de Lausanne
  • Centre Hospitalier Universitaire Vaudois
Topics
  • Health Sciences › Medicine › Epidemiology › Cervical Cancer and HPV Research
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Life Sciences › Immunology and Microbiology › Microbiology › Reproductive tract infections research
Keywords
HPV genotyping, low-cost diagnostic test, multiple HPV infection, assay validation, assay concordance, HPV 56, HPV52, proficiency testing, low-resource laboratories
MeSH terms
Adult, Female, Genotype, Humans, Membranes, Middle Aged, Nucleic Acid Hybridization, Sensitivity and Specificity, Virology, Polymerase Chain Reaction, Clinical Laboratory Techniques, Papillomaviridae, Papillomavirus Infections

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review