Neutralization of bacterial lipopolysaccharides by human plasma
Open accessThe DOI matches its Crossref record.
Abstract
To quantify the neutralization of bacterial lipopolysaccharide (LPS) by human plasma, dilutions of Escherichia coli O113 LPS were incubated with plasma, followed by the addition of Limulus amebocyte lysate (LAL). The reaction between the LPS and LAL was monitored spectrophotometrically, and the concentration of LPS resulting in 50% lysate response (LR50) was determined. Analysis of 145 outdated plasma samples yielded a range of LR50 between 6 and 1,500 ng/ml. Pools of plasma with high and low LR50 were prepared. The pool with high LR50 neutralized 166-fold more E. coli 0113 LPS, 190-fold more E. coli 0111B4 LPS, 42-fold more Klebsiella pneumoniae LPS, and 29-fold more Salmonella typhimurium LPS than did the pool with low LR50. Each pool had similar immunoglobulin G (IgG) and IgM antibody levels to homologous LPS, measured by an enzyme-linked immunosorbent assay. Analysis of 212 fresh-frozen plasma units revealed a range of LR50 between 48 and 6,000 ng/ml. Incubation of LPS in a pool of fresh-frozen plasma with high LR50 elicited significantly less fever in the rabbit pyrogen test than did LPS incubated in plasma with low LR50 (fever index, 2.68 +/- 0.61 degrees C X h and 3.52 +/- 0.66 degrees C X h, respectively; P = 0.003). We conclude that there is a 100-fold range in the endotoxin-neutralizing capacity of human plasma and that this variation is not due to LPS-specific IgG or IgM antibodies. Further investigations are needed to determine whether differing susceptibility of patients to the effects of LPS is due to differences in the endotoxin-neutralizing capacity of their plasma and whether plasma screened for high endotoxin-neutralizing capacity may be therapeutically useful in endotoxemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fukui, H., Brauner, B., Bode, J. C., & Bode, C. (1991) · Journal of Hepatology · doi:10.1016/0168-8278(91)90933-3 · Cited by 461
Endotoxin and the hypothalamo-pituitary-adrenal (HPA) axis
Beishuizen, A., & Thijs, L. G. (2003) · Journal of Endotoxin Research · doi:10.1179/096805103125001298 · Cited by 315
Endotoxemia: Methods of detection and clinical correlates
Hurley, J. C. (1995) · Clinical Microbiology Reviews · doi:10.1128/cmr.8.2.268 · Cited by 318
Calandra, T., Glauser, M. P., Schellekens, J., & Verhoef, J. (1988) · Journal of Infectious Diseases · doi:10.1093/infdis/158.2.312 · Cited by 263
Endotoxemia—menace, marker, or mistake?
Munford, R. S. (2016) · Journal of Leukocyte Biology · doi:10.1189/jlb.3ru0316-151r · Cited by 219
“This assay measures the overall endotoxin-neutralizing capacity of plasma [102, 103]; a decrease in ENA is regarded as evidence that endotoxin is or was present.”
Method
Metadata
- Authors
- Warren, H. S., Novitsky, T. J., Ketchum, P. A., Roslansky, P. F., Kania, S., & Siber, G. R.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1985-10
- Volume
- 22
- Issue
- 4
- Pages
- 590-595
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1546265878
- Cited by
- 65
- References
- 0
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neutralization of bacterial lipopolysaccharides by human plasma. https://app.cochat.ai/papers/10.1128/jcm.22.4.590-595.1985
- The paper
- Warren, H. S., Novitsky, T. J., Ketchum, P. A., Roslansky, P. F., Kania, S., & Siber, G. R. (1985). Neutralization of bacterial lipopolysaccharides by human plasma. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.22.4.590-595.1985
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.