Phenotypic variation of Staphylococcus epidermidis in infection of transvenous endocardial pacemaker electrodes
Open accessThe DOI matches its Crossref record.
Abstract
Coagulase-negative staphylococci isolated from a patient with a pacemaker electrode infection were extensively evaluated by phenotypic and genotypic characterization. Findings from this evaluation were striking because different colony morphologic subtypes were recovered from blood and resected pacemaker electrodes. Staphylococci from each colony subtype (LBL, LBV, LBP, LBS) were identified as slime-producing strains of Staphylococcus epidermidis sensu stricto. Direct plating of isolates from a restricted electrode revealed a mixture of colony phenotypes when examined on a high-salt, low-glucose medium, Memphis agar. Bacteriophage typing employing 17 different phages and plasmid profile analysis were largely unsuccessful in further characterizing bacterial cells of each of the four colony morphotypes. On the other hand, restriction endonuclease analysis by EcoRI digestion of the chromosomal DNA demonstrated the probable common clonal origin of the four colony phenotypes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coagulase-Negative Staphylococci
Becker, K., Heilmann, C., & Peters, G. (2014) · Clinical Microbiology Reviews · doi:10.1128/cmr.00109-13 · Cited by 1,628
Götz, F. (2002) · Molecular Microbiology · doi:10.1046/j.1365-2958.2002.02827.x · Cited by 1,178
Proctor, R. A., von Eiff, C., Kahl, B. C., Becker, K., McNamara, P., Herrmann, M., & Peters, G. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1384 · Cited by 1,175
Baddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Self-citationMolecular basis of intercellular adhesion in the biofilm‐forming Staphylococcus epidermidis
Heilmann, C., Schweitzer, O., Gerke, C., Vanittanakom, N., Mack, D., & Götz, F. (1996) · Molecular Microbiology · doi:10.1111/j.1365-2958.1996.tb02548.x · Cited by 922
Antibiotic resistance and persistence—implications for human health and treatment perspectives
Huemer, M., Mairpady Shambat, S., Brugger, S. D., & Zinkernagel, A. S. (2020) · The EMBO Reports · doi:10.15252/embr.202051034 · Cited by 850
“Among these difficult-to-treat infections are pacemaker-related infections (Baddour et al , 1990; von Eiff et al , 1999), endocarditis (Quie, 1969; Bhattacharyya et al , 2012), osteomyelitis (Proctor et al , 1995), airway infections (Kahl et al , 1998; Besier et al , 2007; Schneider et al , 2008)”
Skeletal infections: microbial pathogenesis, immunity and clinical management
Masters, E. A., Ricciardi, B. F., Bentley, K. L. D. M., Moriarty, T. F., Schwarz, E. M., & Muthukrishnan, G. (2022) · Nature Reviews Microbiology · doi:10.1038/s41579-022-00686-0 · Cited by 735
Heilmann, C., Hussain, M., Peters, G., & Götz, F. (1997) · Molecular Microbiology · doi:10.1046/j.1365-2958.1997.4101774.x · Cited by 700
“…shunts, prosthetic heart valves, continuous ambulatory peritoneal dialysis (CAPD) catheters, cardiac pacemakers, and orthopaedic devices (Cheesbrough et al., 1986; Peters et al., 1982; 1984; George et al., 1979; Karchmer et al., 1983; Inman et al., 1984; Baddour et al., 1990; West et al., 1986).”
BackgroundZiebuhr, W., Krimmer, V., Rachid, S., Lößner, I., Götz, F., & Hacker, J. (1999) · Molecular Microbiology · doi:10.1046/j.1365-2958.1999.01353.x · Cited by 415
Ziebuhr, W., Heilmann, C., Götz, F., Meyer, P., Wilms, K., Straube, E., & Hacker, J. (1997) · Infection and Immunity · doi:10.1128/iai.65.3.890-896.1997 · Cited by 368
Kahl, B. C., Becker, K., & Löffler, B. (2016) · Clinical Microbiology Reviews · doi:10.1128/cmr.00069-15 · Cited by 325
Are coagulase-negative staphylococci virulent?
Heilmann, C., Ziebuhr, W., & Becker, K. (2019) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2018.11.012 · Cited by 298
Heilmann, C., Thumm, G., Chhatwal, G. S., Hartleib, J., Uekötter, A., & Peters, G. (2003) · Microbiology · doi:10.1099/mic.0.26527-0 · Cited by 205
“Staphylococcus epidermidis is the major cause of infections associated with implanted medical devices, such as intravascular catheters, cerebrospinal fluid shunts, prosthetic heart valves, cardiac pacemakers and orthopaedic devices (Baddour et al., 1990; George et al., 1979; Inman et al., 1984; Karchmer et al., 1983;…”
BackgroundThe small colony variant (SCV) concept—the role of staphylococcal SCVs in persistent infections
von Eiff, C., Peters, G., & Becker, K. (2006) · Injury · doi:10.1016/j.injury.2006.04.006 · Cited by 180
Growth and adhesion of Enterococcus faecium L-forms
Jass, J., Phillips, L. E., Allan, E. J., Costerton, J. W., & Lappin-Scott, H. M. (1994) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.1994.tb06631.x · Cited by 14
Metadata
- Authors
- Baddour, L. M., Barker, L. P., Christensen, G. D., Parisi, J. T., & Simpson, W. A.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1990-04
- Volume
- 28
- Issue
- 4
- Pages
- 676-679
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1610052743
- Cited by
- 72
- References
- 0
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.