The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Simple, sensitive, and specific detection of human immunodeficiency virus type 1 in clinical specimens by polymerase chain reaction with nested primers
Open accessAbstract
A simple, sensitive, and specific polymerase chain reaction (PCR) protocol for the detection of human immunodeficiency virus type 1 (HIV-1) is described. We have improved all three PCR steps: sample preparation, DNA amplification, and detection of the amplified product. Some of the improvements have been described previously, but they have never been combined into a complete PCR protocol. Peripheral blood mononuclear cells were lysed directly in a buffer containing sodium dodecyl sulfate, Triton X-100, and proteinase K. This crude cell lysate was amplified in a two-step PCR, first with outer primers and then with inner primers nested within the first primers. The PCR product was visualized by agarose gel electrophoresis and ethidium bromide staining. Thus, we avoided conventional DNA extraction as well as hybridization for the detection of the PCR product. The samples were analyzed with four sets of nested primers (JA4 through JA7, JA9 through JA12, JA13 through JA16, and JA17 through JA20) designed to amplify HIV-1 gag, env gp120, env gp41, and pol sequences, respectively. We were able to amplify HIV-1 sequences in all samples from 90 HIV-1-seropositive individuals with mostly mild symptoms. Of these individuals, 24 were negative in HIV-1 isolation and 9 were selected because they were infected by African and Haitian HIV-1 strains. Eighty-five (94%) individuals were positive with at least three of four primer sets. Samples from 26 healthy blood donors, as well as cells infected in vitro with human immunodeficiency virus type 2 and human T-cell leukemia virus type I, were negative in PCR, thus demonstrating the specificity of the amplification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Cited by
Polymerase chain reaction: basic protocol plus troubleshooting and optimization strategies
Lorenz, T. C. (2012) · Journal of Visualized Experiments · doi:10.3791/3998 · Cited by 493
General concepts for PCR primer design.
Dieffenbach, C. W., Lowe, T. M., & Dveksler, G. S. (1993) · Genome Research · doi:10.1101/gr.3.3.s30 · Cited by 484
Metadata
- Authors
- Albert, J., & Fenyö, E. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1990-07
- Volume
- 28
- Issue
- 7
- Pages
- 1560-1564
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1485928263
- Cited by
- 248
- References
- 2
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple, sensitive, and specific detection of human immunodeficiency virus type 1 in clinical specimens by polymerase chain reaction with nested primers. https://app.cochat.ai/papers/10.1128/jcm.28.7.1560-1564.1990
- The paper
- Albert, J., & Fenyö, E. M. (1990). Simple, sensitive, and specific detection of human immunodeficiency virus type 1 in clinical specimens by polymerase chain reaction with nested primers. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.28.7.1560-1564.1990
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.