CoChat

Selection of candidate quality control isolates and tentative quality control ranges for in vitro susceptibility testing of yeast isolates by National Committee for Clinical Laboratory Standards proposed standard methods

Open access
Pfaller, M A, Bale, M, Buschelman, B, Lancaster, M, Espinel-Ingroff, A, Rex, J H, Rinaldi, M G · 1994 · Journal of Clinical Microbiology
Cited by 59

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The National Committee for Clinical Laboratory Standards has developed a proposed standard method for in vitro antifungal susceptibility testing of yeast isolates (National Committee for Clinical Laboratory Standards, document M27-P, 1992). In order for antifungal testing by the M27-P method to be accepted, reliable quality control (QC) performance criteria must be developed. In the present study, five laboratories tested 10 candidate QC strains 20 times each against three antifungal agents: amphotericin B, fluconazole, and 5-fluorocytosine. All sites conformed to the M27-P standards and used a common lot of tube dilution reagents and RPMI 1640 broth medium. Overall, 98% of MIC results with amphotericin B, 95% with fluconazole, and 92% with 5-fluorocytosine fell within the desired 3-log2 dilution range (mode +/- 1 log2 dilution). Excellent performance with all three antifungal agents was observed for six strains: Candida albicans ATCC 90028, Candida parapsilosis ATCC 90018, C. parapsilosis ATCC 22019, Candida krusei ATCC 6258, Candida tropicalis ATCC 750, and Saccharomyces cerevisiae ATCC 9763. With these strains, 3-log2 dilution ranges encompassing 94 to 100% of MICs for all three drugs were established. Additional studies with multiple lots of RPMI 1640 test medium will be required to establish definitive QC ranges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.32.7.1650-1653.1994

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 59

Metadata

Authors
Pfaller, M. A., Bale, M., Buschelman, B., Lancaster, M., Espinel-Ingroff, A., Rex, J. H., & Rinaldi, M. G.
Venue
Journal of Clinical Microbiology
Published
1994-07
Volume
32
Issue
7
Pages
1650-1653
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1895458779
Cited by
59
References
5
FWCI
6.88
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selection of candidate quality control isolates and tentative quality control ranges for in vitro susceptibility testing of yeast isolates by National Committee for Clinical Laboratory Standards proposed standard methods. https://app.cochat.ai/papers/10.1128/jcm.32.7.1650-1653.1994
The paper
Pfaller, M. A., Bale, M., Buschelman, B., Lancaster, M., Espinel-Ingroff, A., Rex, J. H., & Rinaldi, M. G. (1994). Selection of candidate quality control isolates and tentative quality control ranges for in vitro susceptibility testing of yeast isolates by National Committee for Clinical Laboratory Standards proposed standard methods. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.32.7.1650-1653.1994

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.