Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 338

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Immunoblot interpretation criteria for serodiagnosis of early Lyme disease

Open access
Engstrom, S M, Shoop, E, Johnson, R C·1995·Journal of Clinical Microbiology

Abstract

We monitored the antibody responses of 55 treated patients with early Lyme disease and physician-documented erythema migrans. Six sequential serum samples were obtained from patients before, during, and until one year after antibiotic therapy and analyzed by in-house enzyme-linked immunosorbent (ELISA) and immunoblot assays. An immunoblot procedure utilizing a gradient gel and an image analysis system was developed. A relational database management system was used to analyze the results and provide criteria for early disease immunoblot interpretation. Recommended criteria for the immunoglobulin M (IgM) immunoblot are the recognition of two of three proteins (24, 39, and 41 kDa). The recommended criteria for a positive IgG immunoblot are the recognition of two of five proteins (20, 24 [> 19 intensity units], 35, 39, and 88 kDa). Alternatively, if band intensity cannot be measured, the 22-kDa protein can be substituted for the 24-kDa protein with only a small decrease in sensitivity. Monoclonal antibodies were used to identify all these proteins except the 35-kDa protein. With the proposed immunoblot interpretations, the sequential serum samples were examined. At visit 1, the day of diagnosis and initiation of treatment, 54.5% of the serum samples were either IgM or IgG positive. The peak antibody response, with 80% of the serum samples positive, occurred at visit 2, 8 to 12 days into treatment. The sensitivities of the IgM and IgG immunoblot for detecting patients that were seropositive into the study period were 58.5 and 54.6%, respectively, at visit 1 and 100% at visit 2. Twenty percent of the patients remained seronegative throughout the study. The specificities of the IgM and IgG immunoblots were 92 to 94% and 93 to 96%, respectively. The IgM immunoblot and ELISA were similar in sensitivities, whereas the IgG immunoblot had greater sensitivity than the IgG ELISA (P = 0.006).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.33.2.419-427.1995

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 338

Metadata

Authors
Engstrom, S. M., Shoop, E., & Johnson, R. C.
Venue
Journal of Clinical Microbiology
Published
1995-02
Volume
33
Issue
2
Pages
419-427
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2162689245
Cited by
338
References
13
FWCI
16.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immunoblot interpretation criteria for serodiagnosis of early Lyme disease. https://app.cochat.ai/papers/10.1128/jcm.33.2.419-427.1995
The paper
Engstrom, S. M., Shoop, E., & Johnson, R. C. (1995). Immunoblot interpretation criteria for serodiagnosis of early Lyme disease. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.33.2.419-427.1995

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.