Rapid reverse transcription-PCR detection of hepatitis C virus RNA in serum by using the TaqMan fluorogenic detection system
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe the application of a new fluorogenic probe-based PCR assay (TaqMan; Perkin Elmer Corp./Applied Biosystems, Foster City, Calif.) for the detection of hepatitis C virus RNA in serum and plasma. This assay allows for the direct direction of specific PCR products within minutes of completion of the PCR by monitoring the increase in fluorescence of a dye-labeled oligonucleotide probe. We evaluated this assay by comparing the results obtained by nested PCR with those obtained by TaqMan PCR. Test samples included two separate dilutions series of plasma samples from experimentally infected chimpanzees and a panel of 48 serum specimens from patients with community-acquired hepatitis C virus. The quantity of HCV RNA in each chimpanzee plasma sample was determined by using branched DNA (bDNA) signal amplification assay (Quantiplex HCV RNA assay; Chiron Corp., Emeryville, Calif.). Both PCR assays demonstrated similar levels of detection and could reliably detect 13 bDNA genome equivalents per sample. We found an overall concordance of 88% between results of two PCR assays with the community-acquired panel, which resolved to 100% when discrepant samples were retested by nested PCR. TaqMan compared favorably with nested PCR with key advantages of speed, increased throughput, and decreased opportunity for false-positive results because of elimination of second-round amplification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Natural History of Community-Acquired Hepatitis C in the United States
Alter, M. J., Margolis, H. S., Krawczynski, K., Judson, F. N., Mares, A., Alexander, W. J., Hu, P. Y., Miller, J. K., Gerber, M. A., Sampliner, R. E., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199212313272702 · Cited by 1,592 · cited 3×
“was performed as previously described (3).”
MethodInfluential
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Lanciotti, R. S., Kerst, A. J., Nasci, R. S., Godsey, M. S., Mitchell, C. J., Savage, H. M., Komar, N., Panella, N. A., Allen, B. C., Volpe, K. E., et al. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.11.4066-4071.2000 · Cited by 1,087
“These TaqMan detection assays offer the advantage over traditional RT-PCR of increased sensitivity, higher throughput, increased reproducibility, and better quantitation (5, 8, 10, 16).”
MethodAdvanced methods of plant disease detection. A review
Martinelli, F., Scalenghe, R., Davino, S., Panno, S., Scuderi, G., Ruisi, P., Villa, P., Stroppiana, D., Boschetti, M., Goulart, L. R., et al. (2015) · Agronomy for Sustainable Development · doi:10.1007/s13593-014-0246-1 · Cited by 964
Takai, K., & Horikoshi, K. (2000) · Applied and Environmental Microbiology · doi:10.1128/aem.66.11.5066-5072.2000 · Cited by 883
Rapid and quantitative detection of human adenovirus DNA by real‐time PCR
Heim, A., Ebnet, C., Harste, G., & Pring‐Åkerblom, P. (2003) · Journal of Medical Virology · doi:10.1002/jmv.10382 · Cited by 820
Metadata
- Authors
- Morris, T., Robertson, B., & Gallagher, M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1996-12
- Volume
- 34
- Issue
- 12
- Pages
- 2933-2936
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2109468737
- Cited by
- 137
- References
- 1
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid reverse transcription-PCR detection of hepatitis C virus RNA in serum by using the TaqMan fluorogenic detection system. https://app.cochat.ai/papers/10.1128/jcm.34.12.2933-2936.1996
- The paper
- Morris, T., Robertson, B., & Gallagher, M. (1996). Rapid reverse transcription-PCR detection of hepatitis C virus RNA in serum by using the TaqMan fluorogenic detection system. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.34.12.2933-2936.1996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.