CoChat

Enolase antigen, mannan antigen, Cand-Tec antigen, and beta-glucan in patients with candidemia

Open access
Mitsutake, K, Miyazaki, T, Tashiro, T, Yamamoto, Y, Kakeya, H, Otsubo, T, Kawamura, S, Hossain, M A, Noda, T, Hirakata, Y, Kohno, S · 1996 · Journal of Clinical Microbiology
Cited by 127

The DOI matches its Crossref record.

Abstract

We compared the specificities and sensitivities of four tests used for the serodiagnosis of candidemia in 39 patients with candidemia, including 10 patients with superficial Candida colonization, 10 patients with deep mycosis, and 20 healthy subjects. The results obtained by the dot immunoblotting assay for detecting the enolase antigen (48 kDa) were compared with those of assays for detecting mannan antigen, heat-labile antigen (a threshold titer of four times), and beta-glucan (> or = 60 pg/ml). Enolase antigen was detected in 28 (71.8%) patients with candidemia, while 30 (76.9%), 10 (25.6%), and 27 (84.4%) patients were positive for the heat-labile antigen by the Cand-Tec assay, the mannan antigen by the Pastorex Candida assay, and beta-glucan by the limulus test, respectively. Ten patients with superficial Candida colonization, 5 patients with invasive pulmonary aspergillosis, 5 patients with cryptococcosis, and 20 healthy subjects were negative for both enolase antigen and mannan antigen. Two patients with superficial Candida colonization, one patient with invasive pulmonary aspergillosis, and two patients with cryptococcosis were positive by the Cand-Tec assay. The beta-glucan concentration was more than 60 pg/ml in all patients with invasive pulmonary aspergillosis; however, it was less than 10 pg/ml in all patients with cryptococcosis. The specificity of enolase antigen in the serodiagnosis of candidemia was 100%, but the sensitivity was 71.8%. The specificity and sensitivity of Cand-Tec, the assay for mannan antigen, and the assay for beta-glucan were 76.9 and 87.5%, 25.6 and 100%, and 84.4 and 87.5%, respectively. Our results demonstrated that antigen detection tests are useful for the diagnosis of candidemia; however, none is satisfactory for the serodiagnosis of candidemia. We suggest that a combination of two assays may increase the accuracy of diagnosis of candidiasis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.34.8.1918-1921.1996

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 127

Metadata

Authors
Mitsutake, K., Miyazaki, T., Tashiro, T., Yamamoto, Y., Kakeya, H., Otsubo, T., Kawamura, S., Hossain, M. A., Noda, T., Hirakata, Y., & Kohno, S.
Venue
Journal of Clinical Microbiology
Published
1996-08
Volume
34
Issue
8
Pages
1918-1921
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2125874235
Cited by
127
References
0
FWCI
3.72
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enolase antigen, mannan antigen, Cand-Tec antigen, and beta-glucan in patients with candidemia. https://app.cochat.ai/papers/10.1128/jcm.34.8.1918-1921.1996
The paper
Mitsutake, K., Miyazaki, T., Tashiro, T., Yamamoto, Y., Kakeya, H., Otsubo, T., Kawamura, S., Hossain, M. A., Noda, T., Hirakata, Y., & Kohno, S. (1996). Enolase antigen, mannan antigen, Cand-Tec antigen, and beta-glucan in patients with candidemia. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.34.8.1918-1921.1996

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.