Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record.

False-positive results in immunoglobulin M (IgM) toxoplasma antibody tests and importance of confirmatory testing: the Platelia Toxo IgM test

Open access
Liesenfeld, O, Press, C, Montoya, J G, Gill, R, Isaac-Renton, J L, Hedman, K, Remington, J S·1997·Journal of Clinical Microbiology

Abstract

Although tests for detection of immunoglobulin M (IgM) toxoplasma antibodies have been reported to have a high degree of accuracy, it is well recognized by investigators in the United States and Europe that false-positive results may occur with many of these tests, at times to an alarming degree. Unfortunately, this information is not well documented in the literature. Studies on various toxoplasma IgM test kits are frequently flawed. The investigators often use reference tests which have not previously been carefully evaluated as well as sera that were not appropriate to answer the question of how often false-positive results might occur. We recently had the unique opportunity to evaluate the accuracy of the Platelia Toxo IgM test in 575 serum samples obtained during an outbreak of toxoplasmosis which occurred in 1995 in the Capital Regional District of British Columbia, Canada. When compared with results obtained in a reference IgM enzyme-linked immunosorbent assay (ELISA), the Platelia Toxo IgM test had a sensitivity of 99.4%, specificity of 49.2%, positive predictive value of 51.9%, negative predictive value of 99.3%, and an overall agreement of 67.0%. In an attempt to resolve discrepancies between these two tests, a serological profile (Sabin-Feldman dye test, IgA and IgE antibody tests, differential agglutination [AC/HS] test, and IgG avidity method) was performed. Of 153 serum samples that were positive in the Platelia Toxo IgM test and negative in the IgM ELISA, 71 (46.4%) were negative in the Sabin-Feldman dye test. Of the serum samples that were positive in the dye test, 77 (93.9%) had a serological profile most compatible with an infection acquired in the distant past. These results reveal high numbers of false-positive results in the Platelia Toxo IgM test and highlight the importance of appropriate evaluation of commercial tests that are currently being marked. Our results also emphasize the importance of confirmatory testing to determine whether the results of an IgM antibody test reflect the likelihood of a recently acquired infection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.35.1.174-178.1997

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 265

Metadata

Authors
Liesenfeld, O., Press, C., Montoya, J. G., Gill, R., Isaac-Renton, J. L., Hedman, K., & Remington, J. S.
Venue
Journal of Clinical Microbiology
Published
1997-01
Volume
35
Issue
1
Pages
174-178
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2112990453
Cited by
265
References
0
FWCI
5.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: False-positive results in immunoglobulin M (IgM) toxoplasma antibody tests and importance of confirmatory testing: the Platelia Toxo IgM test. https://app.cochat.ai/papers/10.1128/jcm.35.1.174-178.1997
The paper
Liesenfeld, O., Press, C., Montoya, J. G., Gill, R., Isaac-Renton, J. L., Hedman, K., & Remington, J. S. (1997). False-positive results in immunoglobulin M (IgM) toxoplasma antibody tests and importance of confirmatory testing: the Platelia Toxo IgM test. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.35.1.174-178.1997

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.