Comparison of Use of Cerebrospinal Fluid, Serum, and Throat Swab Specimens in Diagnosis of Enteroviral Acute Neurological Infection by a Rapid RNA Detection PCR Assay
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A PCR assay for detection of enterovirus RNA in multiple specimen types from patients with neurological infections was evaluated. Combined PCR assay of cerebrospinal fluid and serum (systemic specimens) was more sensitive than assaying either specimen alone in children but not in adults. Compared with PCR in systemic specimens, detection of enterovirus RNA in throat swabs showed a sensitivity of 62.5% and a specificity of 75.6%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enteroviral infections of the central nervous system.
Rotbart, H. A. (1995) · Clinical Infectious Diseases · doi:10.1093/clinids/20.4.971 · Cited by 312 · cited 2×
“Enteroviruses (EVs) of the Picornaviridae family, including the polioviruses, echoviruses, group A and B coxsackieviruses, and more recently numbered EVs (67 distinct serotypes) are important human pathogens (10, 14).”
BackgroundResult
Cited by
Enterovirus and parechovirus infection in children: a brief overview
de Crom, S. C. M., Rossen, J. W. A., van Furth, A. M., & Obihara, C. C. (2016) · European Journal of Pediatrics · doi:10.1007/s00431-016-2725-7 · Cited by 192
Enterovirus infections: diagnosis and treatment.
SAWYER, M. H. (1999) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-199912000-00002 · Cited by 127
Kupila, L., Vuorinen, T., Vainionpaa, R., Marttila, R. J., & Kotilainen, P. (2005) · Clinical Infectious Diseases · doi:10.1086/428581 · Cited by 112
de Crom, S. C. M., Obihara, C. C., de Moor, R. A., Veldkamp, E. J. M., van Furth, A. M., & Rossen, J. W. A. (2013) · Journal of Clinical Virology · doi:10.1016/j.jcv.2013.07.017 · Cited by 61
“[8] and Rittichier et al.”
BackgroundInfluentialArchimbaud, C., Mirand, A., Chambon, M., Regagnon, C., Bailly, J., Peigue‐Lafeuille, H., & Henquell, C. (2004) · Journal of Medical Virology · doi:10.1002/jmv.20217 · Cited by 28
“Detection of the enterovirus in cerebrospinal fluid (CSF) specimens by reverse-transcription polymerase chain reaction (RT-PCR) is more rapid and sensitive than by viral culture [Andreoletti et al., 1998; Romero, 1999; Chambon et al., 2001; Henquell et al., 2001; Corless et al., 2002].”
Metadata
- Authors
- Andréoletti, L., Blassel-Damman, N., Dewilde, A., Vallée, L., Cremer, R., Hober, D., & Wattré, P.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1998-02
- Volume
- 36
- Issue
- 2
- Pages
- 589-591
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2158242091
- Cited by
- 47
- References
- 1
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Use of Cerebrospinal Fluid, Serum, and Throat Swab Specimens in Diagnosis of Enteroviral Acute Neurological Infection by a Rapid RNA Detection PCR Assay. https://app.cochat.ai/papers/10.1128/jcm.36.2.589-591.1998
- The paper
- Andréoletti, L., Blassel-Damman, N., Dewilde, A., Vallée, L., Cremer, R., Hober, D., & Wattré, P. (1998). Comparison of Use of Cerebrospinal Fluid, Serum, and Throat Swab Specimens in Diagnosis of Enteroviral Acute Neurological Infection by a Rapid RNA Detection PCR Assay. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.36.2.589-591.1998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.