The DOI matches its Crossref record.
Development of a High-Throughput Quantitative Assay for Detecting Herpes Simplex Virus DNA in Clinical Samples
Open accessAbstract
We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 10 8 copies of HSV DNA/20 μl of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2). These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a 7-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rapid and quantitative detection of human adenovirus DNA by real‐time PCR
Heim, A., Ebnet, C., Harste, G., & Pring‐Åkerblom, P. (2003) · Journal of Medical Virology · doi:10.1002/jmv.10382 · Cited by 820
Once-daily valacyclovir to reduce the risk of transmission of genital herpes.
Corey, L., Wald, A., Patel, R., Sacks, S. L., Tyring, S. K., Warren, T., Douglas, J. M., Paavonen, J., Morrow, R. A., Beutner, K. R., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa035144 · Cited by 720
Self-citationBrown, Z. A., Wald, A., Morrow, R. A., Selke, S., Zeh, J., & Corey, L. (2003) · JAMA · doi:10.1001/jama.289.2.203 · Cited by 679
Self-citationBeyond Viruses: Clinical Profiles and Etiologies Associated with Encephalitis
Glaser, C. A., Honarmand, S., Anderson, L. J., Schnurr, D. P., Forghani, B., Cossen, C. K., Schuster, F. L., Christie, L. J., & Tureen, J. H. (2006) · Clinical Infectious Diseases · doi:10.1086/509330 · Cited by 650
Reactivation of Genital Herpes Simplex Virus Type 2 Infection in Asymptomatic Seropositive Persons
Wald, A., Zeh, J., Selke, S., Warren, T., Ryncarz, A. J., Ashley, R., Krieger, J. N., & Corey, L. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003233421203 · Cited by 582
Self-citation
Metadata
- Authors
- Ryncarz, A. J., Goddard, J., Wald, A., Huang, M.-L., Roizman, B., & Corey, L.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1999-06
- Volume
- 37
- Issue
- 6
- Pages
- 1941-1947
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2146812842
- Cited by
- 215
- References
- 0
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a High-Throughput Quantitative Assay for Detecting Herpes Simplex Virus DNA in Clinical Samples. https://app.cochat.ai/papers/10.1128/jcm.37.6.1941-1947.1999
- The paper
- Ryncarz, A. J., Goddard, J., Wald, A., Huang, M.-L., Roizman, B., & Corey, L. (1999). Development of a High-Throughput Quantitative Assay for Detecting Herpes Simplex Virus DNA in Clinical Samples. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.37.6.1941-1947.1999
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.