Development of a High-Throughput Quantitative Assay for Detecting Herpes Simplex Virus DNA in Clinical Samples
Open accessThe DOI matches its Crossref record.
Abstract
We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 10 8 copies of HSV DNA/20 μl of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2). These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a 7-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Rapid and quantitative detection of human adenovirus DNA by real‐time PCR
Heim, A., Ebnet, C., Harste, G., & Pring‐Åkerblom, P. (2003) · Journal of Medical Virology · doi:10.1002/jmv.10382 · Cited by 820
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Once-daily valacyclovir to reduce the risk of transmission of genital herpes.
Corey, L., Wald, A., Patel, R., Sacks, S. L., Tyring, S. K., Warren, T., Douglas, J. M., Paavonen, J., Morrow, R. A., Beutner, K. R., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa035144 · Cited by 720
Self-citationBrown, Z. A., Wald, A., Morrow, R. A., Selke, S., Zeh, J., & Corey, L. (2003) · JAMA · doi:10.1001/jama.289.2.203 · Cited by 679
Self-citationBeyond Viruses: Clinical Profiles and Etiologies Associated with Encephalitis
Glaser, C. A., Honarmand, S., Anderson, L. J., Schnurr, D. P., Forghani, B., Cossen, C. K., Schuster, F. L., Christie, L. J., & Tureen, J. H. (2006) · Clinical Infectious Diseases · doi:10.1086/509330 · Cited by 650
Reactivation of Genital Herpes Simplex Virus Type 2 Infection in Asymptomatic Seropositive Persons
Wald, A., Zeh, J., Selke, S., Warren, T., Ryncarz, A. J., Ashley, R., Krieger, J. N., & Corey, L. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003233421203 · Cited by 582
Self-citationFatal Avian Influenza A (H5N1) in a Child Presenting with Diarrhea Followed by Coma
de Jong, M. D., Cam, B. V., Qui, P. T., Hien, V. M., Thanh, T. T., Hue, N. B., Beld, M., Phuong, L. T., Khanh, T. H., Chau, N. V. V., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa044307 · Cited by 530
Mucosal Shedding of Human Herpesvirus 8 in Men
Pauk, J., Huang, M.-L., Brodie, S. J., Wald, A., Koelle, D. M., Schacker, T., Celum, C., Selke, S., & Corey, L. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011093431904 · Cited by 503
Self-citationA population-based study of primary human herpesvirus 6 infection
Zerr, D. M., Meier, A. S., Selke, S. S., Frenkel, L. M., Huang, M.-L., Wald, A., Rhoads, M. P., Nguy, L., Bornemann, R., Morrow, R. A., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042207 · Cited by 462
Self-citationClinical Outcomes of Human Herpesvirus 6 Reactivation after Hematopoietic Stem Cell Transplantation
Zerr, D. M., Corey, L., Kim, H. W., Huang, M., Nguy, L., & Boeckh, M. (2005) · Clinical Infectious Diseases · doi:10.1086/428060 · Cited by 338
Self-citationWald, A., Huang, M., Carrell, D., Selke, S., & Corey, L. (2003) · The Journal of Infectious Diseases · doi:10.1086/379043 · Cited by 330
Self-citationTronstein, E. (2011) · JAMA · doi:10.1001/jama.2011.420 · Cited by 298
Loeffler, J., Henke, N., Hebart, H., Schmidt, D., Hagmeyer, L., Schumacher, U., & Einsele, H. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.2.586-590.2000 · Cited by 289
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
Diagnosing Herpesvirus Infections by Real-Time Amplification and Rapid Culture
van Doornum, G. J. J., Guldemeester, J., Osterhaus, A. D. M. E., & Niesters, H. G. M. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.2.576-580.2003 · Cited by 270
Bach, H.-J., Tomanova, J., Schloter, M., & Munch, J. C. (2002) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(01)00370-0 · Cited by 236
Quantitation of Viral Load Using Real-Time Amplification Techniques
Niesters, H. G. M. (2001) · Methods · doi:10.1006/meth.2001.1264 · Cited by 220
Diagnosis of genital herpes simplex virus infection in the clinical laboratory
LeGoff, J., Péré, H., & Bélec, L. (2014) · Virology Journal · doi:10.1186/1743-422x-11-83 · Cited by 188
“Several procedures have been proposed to detect and/ or quantify HSV genomes in clinical samples, including in-house competitive PCR [33], PCR detection followed by DNA enzyme immunoassay hybridization [34], realtime PCR assay [4,5,35,36], and various commercially available kits.”
BackgroundMethodPCR in Diagnosis of Infection: Detection of Bacteria in Cerebrospinal Fluids
Yamamoto, Y. (2002) · Clinical and Vaccine Immunology · doi:10.1128/cdli.9.3.508-514.2002 · Cited by 179
“The process utilizes two consecutive PCRs.”
InfluentialVerstrepen, W. A., Kuhn, S., Kockx, M. M., Van De Vyvere, M. E., & Mertens, A. H. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.11.4093-4096.2001 · Cited by 177
Watts, D. H., Brown, Z. A., Money, D., Selke, S., Huang, M. L., Sacks, S. L., & Corey, L. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2003.185 · Cited by 177
Self-citationJohnston, C., & Corey, L. (2016) · Clinical Microbiology Reviews · doi:10.1128/cmr.00043-15 · Cited by 177
“Multiple HSV PCR assays are available, several of which detect genes such as that for glycoprotein B (27).”
BackgroundSelf-citationGautheret-Dejean, A., Manichanh, C., Thien-Ah-Koon, F., Fillet, A.-M., Mangeney, N., Vidaud, M., Dhedin, N., Vernant, J.-P., & Agut, H. (2002) · Journal of Virological Methods · doi:10.1016/s0166-0934(01)00390-1 · Cited by 162
Loeb, K. R., Jerome, K. R., Goddard, J., Huang, M.-L., Cent, A., & Corey, L. (2000) · Hepatology · doi:10.1053/jhep.2000.9878 · Cited by 161
Self-citationBrown, Z. A., Wald, A., Morrow, R. A., Selke, S., Zeh, J., & Corey, L. (2003) · Obstetrical & Gynecological Survey · doi:10.1097/01.ogx.0000070126.90718.7b · Cited by 159
Self-citationDetermination of Viral Load by Quantitative Real-Time PCR in Herpes Simplex Encephalitis Patients
Bhullar, S. S., Chandak, N. H., Purohit, H. J., Taori, G. M., Daginawala, H. F., & Kashyap, R. S. (2014) · Intervirology · doi:10.1159/000351521 · Cited by 40
Metadata
- Authors
- Ryncarz, A. J., Goddard, J., Wald, A., Huang, M.-L., Roizman, B., & Corey, L.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1999-06
- Volume
- 37
- Issue
- 6
- Pages
- 1941-1947
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2146812842
- Cited by
- 215
- References
- 0
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.