CoChat

Comparison of Enhanced Mycobacterium tuberculosis Amplified Direct Test with COBAS AMPLICOR Mycobacterium tuberculosis Assay for Direct Detection of Mycobacterium tuberculosis Complex in Respiratory and Extrapulmonary Specimens

Open access
Scarparo, Claudio, Piccoli, Paola, Rigon, Alessandra, Ruggiero, Giuliana, Scagnelli, Mariuccia, Piersimoni, Claudio · 2000 · Journal of Clinical Microbiology
Cited by 88

The DOI matches its Crossref record.

Abstract

The new Roche COBAS AMPLICOR Mycobacterium tuberculosis Assay was compared to the Gen-Probe enhanced Mycobacterium tuberculosis Amplified Direct Test (AMTDII). A total of 486 specimens (296 respiratory and 190 extrapulmonary) collected from 323 patients were tested in parallel with both assays. Results were compared with those of acid-fast staining and culture, setting the combination of culture and clinical diagnosis as the “gold standard.” After resolution of discrepant results, the sensitivity, specificity, and positive and negative predictive values for AMTDII were 85.7, 100, 100, and 90.4% for respiratory specimens and 82.9, 100, 100, and 95.5% for extrapulmonary specimens, respectively. The corresponding values for AMPLICOR were 94.2, 100, 100, and 96.6% for respiratory specimens and 85, 100, 100, and 96.1% for extrapulmonary specimens, respectively. No significant differences were observed between the results of both assays or, within each one, between respiratory and extrapulmonary specimens. The difference between AMTDII and AMPLICOR sensitivities was related to the presence of inhibitory samples, which the former assay, lacking an internal amplification control (IAC), could not detect. The overall inhibition rate for the AMPLICOR assay was 3.9% (19 specimens). It is concluded that, although both amplification assays proved to be rapid and specific for the detection of M. tuberculosis complex in clinical samples, AMPLICOR, by a completely automated amplification and detection procedure, was shown to be particularly feasible for a routine laboratory setting. Finally, AMTDII is potentially an excellent diagnostic technique for both respiratory and extrapulmonary specimens, provided that an IAC is included with the assay.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.38.4.1559-1562.2000

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 88

Metadata

Authors
Scarparo, C., Piccoli, P., Rigon, A., Ruggiero, G., Scagnelli, M., & Piersimoni, C.
Venue
Journal of Clinical Microbiology
Published
2000-04
Volume
38
Issue
4
Pages
1559-1562
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1596639482
Cited by
88
References
0
FWCI
6.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Enhanced Mycobacterium tuberculosis Amplified Direct Test with COBAS AMPLICOR Mycobacterium tuberculosis Assay for Direct Detection of Mycobacterium tuberculosis Complex in Respiratory and Extrapulmonary Specimens. https://app.cochat.ai/papers/10.1128/jcm.38.4.1559-1562.2000
The paper
Scarparo, C., Piccoli, P., Rigon, A., Ruggiero, G., Scagnelli, M., & Piersimoni, C. (2000). Comparison of Enhanced Mycobacterium tuberculosis Amplified Direct Test with COBAS AMPLICOR Mycobacterium tuberculosis Assay for Direct Detection of Mycobacterium tuberculosis Complex in Respiratory and Extrapulmonary Specimens. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.38.4.1559-1562.2000

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).