Comparison of the Serodia Treponema pallidum Particle Agglutination, Captia Syphilis-G, and SpiroTek Reagin II Tests with Standard Test Techniques for Diagnosis of Syphilis
Open accessThe DOI matches its Crossref record.
Abstract
We compared the microhemagglutination assay for Treponema pallidum (MHA-TP), a treponemal test, with two other treponemal tests, the Serodia Treponema pallidum particle agglutination (TP-PA) assay and the Captia Syphilis-G enzyme immunoassay, using 390 clinical serum samples. We also compared two nontreponemal tests, the rapid plasma Reagin (RPR) card test and the SpiroTek Reagin II test. Agreements of the MHA-TP with the TP-PA test and the Syphilis-G test were 97.4 and 97.7%, respectively. There was 89.2% agreement between the RPR and Reagin II tests. The Reagin II test was more apt to be reactive if the treponemal test was also reactive. We conclude that either the Serodia TP-PA test or the Captia Syphilis-G test is an appropriate substitute for the MHA-TP and that the Spirotek Reagin II test could substitute for the RPR test as a screening test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
LaFond, R. E., & Lukehart, S. A. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.29-49.2006 · Cited by 634
Syphilis and HIV Infection: An Update
Zetola, N. M., & Klausner, J. D. (2007) · Clinical Infectious Diseases · doi:10.1086/513427 · Cited by 358
The Laboratory Diagnosis of Syphilis
Ratnam, S. (2005) · Canadian Journal of Infectious Diseases and Medical Microbiology · doi:10.1155/2005/597580 · Cited by 257
Infectious syphilis in high-income settings in the 21st century
Fenton, K. A., Breban, R., Vardavas, R., Okano, J. T., Martin, T., Aral, S., & Blower, S. (2008) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(08)70065-3 · Cited by 240
Recent Trends in the Serologic Diagnosis of Syphilis
Morshed, M. G., & Singh, A. E. (2015) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00681-14 · Cited by 211
“The TPPA has been found to be 131 superior to TPHA, possibly due to the homogenous structure of gel particles (27).”
Background
Metadata
- Authors
- Pope, V., Fears, M. B., Morrill, W. E., Castro, A., & Kikkert, S. E.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2000-07
- Volume
- 38
- Issue
- 7
- Pages
- 2543-2545
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1879238970
- Cited by
- 49
- References
- 0
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the Serodia Treponema pallidum Particle Agglutination, Captia Syphilis-G, and SpiroTek Reagin II Tests with Standard Test Techniques for Diagnosis of Syphilis. https://app.cochat.ai/papers/10.1128/jcm.38.7.2543-2545.2000
- The paper
- Pope, V., Fears, M. B., Morrill, W. E., Castro, A., & Kikkert, S. E. (2000). Comparison of the Serodia Treponema pallidum Particle Agglutination, Captia Syphilis-G, and SpiroTek Reagin II Tests with Standard Test Techniques for Diagnosis of Syphilis. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.38.7.2543-2545.2000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.