CoChat

Evaluation of Two Nested PCR Assays for Detection of Histoplasma capsulatum DNA in Human Tissue

Open access
Bialek, Ralf, Feucht, Antje, Aepinus, Christian, Just-Nübling, Gudrun, Robertson, Valerie J., Knobloch, Jürgen, Hohle, Rolf · 2002 · Journal of Clinical Microbiology
Cited by 203

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In order to evaluate the diagnostic relevance of two nested PCR assays for diagnosis of histoplasmosis in clinical specimens, 100 paraffin-embedded biopsy specimens were examined. Upon microscopy of tissue, 50 biopsy specimens were histoplasma positive and 50 were negative. Due to destruction by formalin fixation, successful extraction of amplifiable human DNA was limited to 29 and 33 samples, respectively. A product of the Histoplasma capsulatum nested PCR assay targeting the gene encoding the unique fungal 100-kDa-like protein was detected in 20 histopathologically positive biopsy specimens but in none of the microscopically negative samples. Sequencing revealed that all 20 products of 210 bp were identical to the sequence of H. capsulatum in the GenBank database. In contrast, the nested PCR assay targeting the fungal 18S rRNA genes amplified products in 26 histopathologically positive but also in 18 microscopically negative biopsy specimens. However, sequencing revealed that only 20 of these 44 PCR products (231 bp) were identical to the sequence of H. capsulatum . The remaining 24 sequences were homologous to those of several Euascomycetes . These PCR products were detected only in tissues possibly colonized by nonpathogenic fungi, possibly causing these nonspecific amplifications. The detection limit of both H. capsulatum nested PCR assays was 1 to 5 fungal cells per sample. The two assays were similarly sensitive in identifying H. capsulatum . In this preliminary study, the novel 100-kDa-like-protein gene nested PCR revealed a specificity of 100% without requiring sequencing, which was necessary for identification of the 18S ribosomal DNA nested PCR products in order to avoid a high rate of false-positive results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.40.5.1644-1647.2002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Bialek, R., Feucht, A., Aepinus, C., Just-Nübling, G., Robertson, V. J., Knobloch, J., & Hohle, R.
Venue
Journal of Clinical Microbiology
Published
2002-05
Volume
40
Issue
5
Pages
1644-1647
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1964260826
Cited by
203
References
1
FWCI
4.52
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Two Nested PCR Assays for Detection of Histoplasma capsulatum DNA in Human Tissue. https://app.cochat.ai/papers/10.1128/jcm.40.5.1644-1647.2002
The paper
Bialek, R., Feucht, A., Aepinus, C., Just-Nübling, G., Robertson, V. J., Knobloch, J., & Hohle, R. (2002). Evaluation of Two Nested PCR Assays for Detection of Histoplasma capsulatum DNA in Human Tissue. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.40.5.1644-1647.2002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.