Comparison of Four Antiseptic Preparations for Skin in the Prevention of Contamination of Percutaneously Drawn Blood Cultures: a Randomized Trial
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A number of skin antiseptics have been used to prevent the contamination of blood cultures, but the comparative efficacies of these agents have not been extensively evaluated. We therefore sought to compare the efficacy of four skin antiseptics in preventing blood culture contamination in a randomized, crossover, investigator-blinded study conducted in an emergency department and the inpatient wards of a university hospital. The patient group included all patients from whom blood samples were obtained percutaneously for culture. Skin antisepsis was performed with 10% povidone-iodine, 70% isopropyl alcohol, tincture of iodine, or povidone-iodine with 70% ethyl alcohol (i.e., Persist). The blood culture contamination rate associated with each antiseptic was then determined. A total of 333 (2.62%) of 12,692 blood cultures were contaminated during the study period compared to 413 (3.21%) of 12,859 blood cultures obtained during the previous 12-month period (relative risk = 0.82; 95% confidence interval, 0.71 to 0.94; P = 0.006). During the study, the contamination rates were determined to be 2.93% with povidone-iodine, 2.58% with tincture of iodine, 2.50% with isopropyl alcohol, and 2.46% with Persist ( P = 0.62). We detected no significant differences in the blood culture contamination rates among these four antiseptics, although there was some evidence suggesting greater efficacy among the alcohol-containing antiseptics. Among the evaluated antiseptics, isopropyl alcohol may be the optimal antiseptic for use prior to obtaining blood for culture, given its convenience, low cost, and tolerability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Self-citation
Cited by
Updated Review of Blood Culture Contamination
Hall, K. K., & Lyman, J. A. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.00062-05 · Cited by 875
Povidone–iodine: use in hand disinfection, skin preparation and antiseptic irrigation
Durani, P., & Leaper, D. (2008) · International Wound Journal · doi:10.1111/j.1742-481x.2007.00405.x · Cited by 221
Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Phlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
“Regardless of the disinfectant used (alcoholic, aqueous or mixed), contamination is most likely a consequence of the poor compliance to the established procedure, the choice of an unsuitable site or the device used to collect blood (29-31).”
Avoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis
Salvagno, G. L., Danese, E., Lima-Oliveira, G., Guidi, G. C., & Lippi, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.023 · Cited by 20
“The use of skin antiseptics before collection of blood specimens is commonplace, for preventing contamination of blood samples, especially those collected for blood culture and other microbiological examinations, as well as for safeguarding patient safety from accidental contamination with bacteria and other pathogens…”
Background
Metadata
- Authors
- Calfee, D. P., & Farr, B. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2002-05
- Volume
- 40
- Issue
- 5
- Pages
- 1660-1665
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2123374398
- Cited by
- 104
- References
- 1
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Four Antiseptic Preparations for Skin in the Prevention of Contamination of Percutaneously Drawn Blood Cultures: a Randomized Trial. https://app.cochat.ai/papers/10.1128/jcm.40.5.1660-1665.2002
- The paper
- Calfee, D. P., & Farr, B. M. (2002). Comparison of Four Antiseptic Preparations for Skin in the Prevention of Contamination of Percutaneously Drawn Blood Cultures: a Randomized Trial. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.40.5.1660-1665.2002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.