Diagnosis of Schistosomiasis by Reagent Strip Test for Detection of Circulating Cathodic Antigen
Open accessThe DOI matches its Crossref record.
Abstract
A newly developed reagent strip assay for the diagnosis of schistosomiasis based on parasite antigen detection in urine of infected individuals was evaluated. The test uses the principle of lateral flow through a nitrocellulose strip of the sample mixed with a colloidal carbon conjugate of a monoclonal antibody specific for Schistosoma circulating cathodic antigen (CCA). The strip assay to diagnose a group of highly infected schoolchildren in Mwanza, Tanzania, demonstrated a high sensitivity and association with the intensity of infection as measured both by egg counts, and by circulating anodic antigen and CCA levels determined by enzyme-linked immunosorbent assay. A specificity of ca. 90% was shown in a group of schistosome-negative schoolchildren from Tarime, Tanzania, an area where schistosomiasis is not endemic. The test is easy to perform and requires no technical equipment or special training. The stability of the strips and the conjugate in the dry format lasts for at least 3 months at ambient temperature in sealed packages, making it suitable for transport and use in areas where schistosomiasis is endemic. This assay can easily be developed to an end-user format.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gryseels, B., Polman, K., Clerinx, J., & Kestens, L. (2006) · The Lancet · doi:10.1016/s0140-6736(06)69440-3 · Cited by 2,084
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Self-citationDesigns, formats and applications of lateral flow assay: A literature review
Sajid, M., Kawde, A.-N., & Daud, M. (2015) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2014.09.001 · Cited by 765
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 576
Conquering schistosomiasis in China: the long march
(2005) · Acta Tropica · doi:10.1016/j.actatropica.2005.08.004 · Cited by 341
Hotez, P. J., & Wilkins, P. P. (2009) · PLoS Neglected Tropical Diseases · doi:10.1371/journal.pntd.0000400 · Cited by 283
Schistosomiasis with a Focus on Africa
Aula, O. P., McManus, D. P., Jones, M. K., & Gordon, C. A. (2021) · Tropical Medicine and Infectious Disease · doi:10.3390/tropicalmed6030109 · Cited by 223
“In addition to egg detection, active infections can be detected from worm-derived circulating anodic antigens (CAAs) and circulating cathodic antigens (CCAs) in serum and urine using enzyme-linked immunosorbent assay (ELISA) or monoclonal- antibody-based lateral flow tests [138,139].”
BackgroundMethodCorstjens, P. L. A. M., van Lieshout, L., Zuiderwijk, M., Kornelis, D., Tanke, H. J., Deelder, A. M., & van Dam, G. J. (2008) · Journal of Clinical Microbiology · doi:10.1128/jcm.00877-07 · Cited by 189
Self-citationAmorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays
Posthuma-Trumpie, G. A., Wichers, J. H., Koets, M., Berendsen, L. B. J. M., & van Amerongen, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5340-5 · Cited by 176
Self-citation
Metadata
- Authors
- van Dam, G. J., Wichers, J. H., Ferreira, T. M. F., Ghati, D., van Amerongen, A., & Deelder, A. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2004-12
- Volume
- 42
- Issue
- 12
- Pages
- 5458-5461
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2131233929
- Cited by
- 248
- References
- 0
- FWCI
- 2.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.