The DOI matches its Crossref record.
Up-Converting Phosphor Technology-Based Lateral Flow Assay for Detection of Schistosoma Circulating Anodic Antigen in Serum
Open accessAbstract
Schistosoma sp. circular anodic antigen (CAA) serum concentrations reflect actual worm burden in a patient and are a valuable tool for population screening and epidemiological research. However, for the diagnosis of individual imported schistosomiasis cases, the current enzyme-linked immunosorbent assay (ELISA) lacks sensitivity and robustness. Therefore, a lateral flow (LF) assay was developed to test CAA in serum for individual diagnosis of imported active schistosome infections. Application of fluorescent submicron-sized up-converting phosphor technology (UPT) reporter particles increased analytical sensitivity compared to that of the standard ELISA method. Evaluation of the UPT-LF test with a selection of 40 characterized epidemiologic samples indicated a good correlation between signal intensity and infection intensity. Subsequently, the UPT-LF assay was applied to 166 serum samples of Dutch residents (immigrants and travelers) suspected of schistosomiasis, a case in which group routine antibody detection frequently fails straightforward diagnosis. The UPT-LF assay identified 36 CAA-positive samples, compared to 15 detected by CAA-ELISA. In conclusion, the UPT-LF assay is a low-complexity test with higher sensitivity than the CAA-ELISA, well suited for laboratory diagnosis of individual active Schistosoma infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zheng, W., Huang, P., Tu, D., Ma, E., Zhu, H., & Chen, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00178h · Cited by 894
Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Huang, X., Aguilar, Z. P., Xu, H., Lai, W., & Xiong, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.032 · Cited by 499
Lanthanide-doped up-converting nanoparticles: Merits and challenges
Gnach, A., & Bednarkiewicz, A. (2012) · Nano Today · doi:10.1016/j.nantod.2012.10.006 · Cited by 393
Metadata
- Authors
- Corstjens, P. L. A. M., van Lieshout, L., Zuiderwijk, M., Kornelis, D., Tanke, H. J., Deelder, A. M., & van Dam, G. J.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2008-01
- Volume
- 46
- Issue
- 1
- Pages
- 171-176
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2132863559
- Cited by
- 189
- References
- 0
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Up-Converting Phosphor Technology-Based Lateral Flow Assay for Detection of Schistosoma Circulating Anodic Antigen in Serum. https://app.cochat.ai/papers/10.1128/jcm.00877-07
- The paper
- Corstjens, P. L. A. M., van Lieshout, L., Zuiderwijk, M., Kornelis, D., Tanke, H. J., Deelder, A. M., & van Dam, G. J. (2008). Up-Converting Phosphor Technology-Based Lateral Flow Assay for Detection of Schistosoma Circulating Anodic Antigen in Serum. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.00877-07
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.