The DOI matches its Crossref record.
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Open accessAbstract
Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 replicase gene, which differ in detection format, amplicon size, and efficiency of amplification. These noncompetitive IC assays, using TaqMan, hybridization probe, or duplex scorpion probe techniques, were tested on the LightCycler and Rotorgene systems. In our approach, clinical specimens were spiked with the control virus to monitor the efficiency of extraction, reverse transcription, and amplification steps. The MS2 RT-PCR assays were applied for internal control when using a second target hepatitis C virus RNA in duplex PCR in blood donor screening. The 95% detection limit was calculated by probit analysis to 44.9 copies per PCR (range, 38.4 to 73.4). As demonstrated routinely, application of MS2 IC assays exhibits low variability and can be applied in various RT-PCR assays. MS2 phage lysates were obtained under standard laboratory conditions. The quantification of phage and template RNA was performed by plating assays to determine PFU or via real-time RT-PCR. High stability of the MS2 phage preparations stored at −20°C, 4°C, and room temperature was demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PCR inhibitors - occurrence, properties and removal
Schrader, C., Schielke, A., Ellerbroek, L., & Johne, R. (2012) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2012.05384.x · Cited by 2,118
Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Burd, E. M. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00074-09 · Cited by 550
Design of virus-based nanomaterials for medicine, biotechnology, and energy
Wen, A. M., & Steinmetz, N. F. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00287g · Cited by 379
Murray, R. J., Robinson, J. O., White, J. N., Hughes, F., Coombs, G. W., Pearson, J. C., Tan, H.-L., Chidlow, G., Williams, S., Christiansen, K. J., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008705 · Cited by 84
Detection of respiratory viruses using a multiplex real-time PCR assay in Germany, 2009/10
Bierbaum, S., Forster, J., Berner, R., Rücker, G., Rohde, G., Neumann-Haefelin, D., Panning, M., & CAPNETZ study group (2014) · Archives of Virology · doi:10.1007/s00705-013-1876-3 · Cited by 42
Metadata
- Authors
- Dreier, J., Störmer, M., & Kleesiek, K.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2005-09
- Volume
- 43
- Issue
- 9
- Pages
- 4551-4557
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2040499564
- Cited by
- 220
- References
- 0
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays. https://app.cochat.ai/papers/10.1128/jcm.43.9.4551-4557.2005
- The paper
- Dreier, J., Störmer, M., & Kleesiek, K. (2005). Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.43.9.4551-4557.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.